# SDR UIEA2021070101452

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 30, 2021
- Submitted: July 6, 2021
- Operation: Air carrier
- Aircraft: [N645GT](https://openairdocs.org/aircraft/N645GT), registered now
- Make and model: Boeing 767324
- Aircraft serial: 27393
- System (JASC): [2150 · Cabin Cooling System](https://openairdocs.org/jasc/2150)
- Part: Controller
- Part number: 6259469
- Part serial: 4466
- Condition: Faulted
- Location: Rt A/C Pack Temp
- Stage of operation: NR
- How discovered: 9
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UIEA2021070101452

## Discrepancy

RT PACK TEMP CONTROL INOP IN AUTO ( PACK TEMPERATURE CONTROL SYSTEMS (-200/-300) , AUTO MODE )(<P>TRANSFERRED TO MEL 21-51-03-01, MDDR 149482, CAT C, DUE 10JUL21.</P> / <P>REMOVED AND REPLACED RT PACK TEMP CONTROLLER AND OPS CHECK IAW 21-51-00. THIS CLEARS MDDR 149482. PLAC REMOVED.</P>)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.