# SDR UPS00833082

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 30, 2000
- Submitted: June 30, 2000
- Operation: Air carrier
- Aircraft: N874UP
- Make and model: Doug DC-8-73F
- Registry model: [Doug DC-8-73F](https://openairdocs.org/model/douglas-dc-8-73f) (OpenAirDocs)
- Aircraft serial: 46074
- System (JASC): [3350 · Emergency Lighting](https://openairdocs.org/jasc/3350)
- Part: Connector
- Condition: Loose
- Location: Battery Pack
- Stage of operation: CL
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UPS00833082

## Discrepancy

ON CLIMBOUT, EMERGENCY LIGHTING ILLUMINATED. ALL ELECTRICAL BUSSES VOLTS / FREQS WERE NORMAL, BATTERY VOLTAGE NORMAL. FOUND EMERGENCY EXIT LIGHTING CONTROL CB POPPED. RESET WITHOUT FURTHER PROBLEMS.(DC BUS 1)     FOUND EMERGENCY LIGHT BATTERY PACK ELECTRICAL CONNECTOR PARTIALLY CONNECTED. RE-CONNECTED ELECTRICAL CONNECTOR  AND SYSTEM OPS CHECKED NORMAL AS PER M/M 33-50-01.

---