# SDR UPS01236683

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 23, 2001
- Submitted: August 24, 2001
- Operation: Air carrier
- Aircraft: [N907UP](https://openairdocs.org/aircraft/N907UP), registered now
- Make and model: Boeing 727-27C
- Registry model: [Boeing 727-27C](https://openairdocs.org/model/boeing-727-27c) (OpenAirDocs)
- Aircraft serial: 19118
- System (JASC): [2920 · Hydraulic System, Auxiliary](https://openairdocs.org/jasc/2920)
- Part: Hydraulic Line
- Part number: BACH8C08NN0290
- Condition: Leaking
- Location: Hydraulic Sys
- Stage of operation: CL
- How discovered: O
- Nature of condition: K, J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UPS01236683

## Discrepancy

INSPECTION TYPE:N/A SHORTLY AFTER TAKEOFF SYSTEM B ELECTRIC SYSTEM LOW PRESSURE LIGHT ILLUMINATED. SYSTEM B QTY INDICATED 0. EMERGENCY CHECKLISTS ACCOMPLISHED AND LANDING WAS UNEVENTFUL. FOUND OUTLET LINE OF NR 2 B PUMP LEAKING. PERFORMED AN INTERIM HOSE REPAIR PER GMM 3-24-1. SERVICED HYDRAULICS AND CKD PSI AND LK CKD NORM (TEMP FLEX LINES INSTALLED AND SECURED) DEFERRED INTERIM HOSE REPAIR PER GMM CHAPTER 3.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.