# SDR UPS01834773

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 25, 2001
- Submitted: January 29, 2001
- Operation: Air carrier
- Aircraft: N868UP
- Make and model: Doug DC-8-73F
- Registry model: [Doug DC-8-73F](https://openairdocs.org/model/douglas-dc-8-73f) (OpenAirDocs)
- Aircraft serial: 45968
- System (JASC): [2710 · Aileron Control System](https://openairdocs.org/jasc/2710)
- Part: Control Cable
- Condition: Contaminated
- Location: Aileron
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UPS01834773

## Discrepancy

INSPECTION TYPE: IN, AILERON POWER S/O LEVER FROZEN.  CLEANED AND LUBED AILERON HYD S/O CABLES GOING THRU BULKHEAD IN LT W/W CABLES HAD BUILD UP OF ANTI CORROSION COMPOUND.  SYS OPS CKS GOOD PER MM 27-10-00.

---