# SDR UPS01835187

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 1, 2001
- Submitted: March 6, 2001
- Operation: Air carrier
- Aircraft: N730UP
- Make and model: Doug DC-8-71F
- Registry model: [Doug DC-8-71F](https://openairdocs.org/model/douglas-dc-8-71f) (OpenAirDocs)
- Aircraft serial: 46030
- System (JASC): [2170 · Humidity Control System](https://openairdocs.org/jasc/2170)
- Part: Separator
- Condition: Malfunctioned
- Location: Ac Bay
- Stage of operation: CR
- How discovered: O
- Nature of condition: B
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UPS01835187

## Discrepancy

INSPECTION TYPE:IN FUMES IN C/P DURING ENTIRE FLIGHT, SEEM TO BE COMING FROM EITHER PACK.  ON GROUND FOUND R PACK EMITTING ODOR.  DER R PACK PER MEL 21-38-1.  PERF MAINTENANCE PROCEDURES. M 210419 ASSIGNED PLACARDS INSTALLED.  REMOVED AND REPLACED RT WATER SEPARATOR IAW 21-55-03.  PERFORMED ADJUSTMENT AND TEST IAW 21-55-00.  ALL CHECK GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.