# SDR UPS02837719

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 19, 2002
- Submitted: February 22, 2002
- Operation: Air carrier
- Aircraft: N801UP
- Make and model: Doug DC-8-73F
- Registry model: [Doug DC-8-73F](https://openairdocs.org/model/douglas-dc-8-73f) (OpenAirDocs)
- Aircraft serial: 46101
- System (JASC): [2450 · AC Power Distribution System](https://openairdocs.org/jasc/2450)
- Part: Control Panel
- Condition: Failed
- Location: Cockpit
- Stage of operation: CR
- How discovered: O
- Nature of condition: H
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UPS02837719

## Discrepancy

INSPECTION TYPE:N/A NR 2 BUS AND LT EMERGENCY BUS FAILED.  CREW DECLARED EMERGENCY.  LANDING UNEVENTFUL.  T/S PER M/M 24-20-00 REMOVED AND REPLACED NR 2 GENERATOR CONTROL PANEL AND PERFORMED ADJ/TEST PER 24-20-06, OPS CHECKS NORMAL.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.