# SDR UPS05844933

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 20, 2005
- Submitted: July 20, 2005
- Operation: Air carrier
- Aircraft: N702UP
- Make and model: Doug DC-8-71F
- Registry model: [Doug DC-8-71F](https://openairdocs.org/model/douglas-dc-8-71f) (OpenAirDocs)
- Aircraft serial: 45902
- System (JASC): [2910 · Hydraulic System, Main](https://openairdocs.org/jasc/2910)
- Part: Hydraulic System
- Condition: Leaking
- Stage of operation: CL
- How discovered: O
- Nature of condition: K, J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UPS05844933

## Discrepancy

ATB - HYDRAULIC FLUID LOSS, EMERGENCY DECLARED.   FOUND LEFT MAIN GEAR DOWNLOCK BUNGEE CYLINDER PRESSURE LINE LEAKING/ DAMAGED. R/R LINE PER MM 30-12-2. SVCD HYD SYSTEM PER MM 12-30-01-3 LEAK CK O.K.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.