# SDR UPS06447484

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 4, 2006
- Submitted: July 31, 2006
- Operation: Air carrier
- Aircraft: [N676UP](https://openairdocs.org/aircraft/N676UP), registered now
- Make and model: Boeing 747123F
- Aircraft serial: 20101
- Aircraft time: 83,907 hours, 23,132 cycles
- System (JASC): [5315 · Fuselage Main, Floor Beam](https://openairdocs.org/jasc/5315)
- Part: Floorbeam
- Condition: Corroded
- Location: Fuselage
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UPS06447484

## Discrepancy

INSPECTION TYPE:C FWD CARGO COMPT LT STA 760 IN BETWEEN LBL40 AND LBL45 FLOORBEAM UPPER CHORD FOUND CORROSION.  CORROSION BLEND OUT 0.030" BY 3/4" BY 1 3/4" EXCEED SRM LIMIT.  FWD CARGO COMPT BS760 LBL40 - LBL45 FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 51-40-04 FIG 2.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.