# SDR UPS06447501

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 4, 2006
- Submitted: August 2, 2006
- Operation: Air carrier
- Aircraft: [N676UP](https://openairdocs.org/aircraft/N676UP), registered now
- Make and model: Boeing 747123F
- Aircraft serial: 20101
- Aircraft time: 83,907 hours, 23,132 cycles
- System (JASC): [5315 · Fuselage Main, Floor Beam](https://openairdocs.org/jasc/5315)
- Part: Floorbeam
- Condition: Corroded
- Location: Fuselage
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UPS06447501

## Discrepancy

AFT CARGO COMPT, LT STA1500 IN BETWEEN LBL30 AND LBL45 FLOORBEAM UPPER CHORD FOUND CORROSION.  CORROSION BLEND OUT 0.024" BY 1" BY 6".  FLOORBEAM UPPER CHORD AT STA 1500 LBL 28 TO MOST O/B REPAIRED AS PER SRM 51-40-04 FIG 2.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.