# SDR UPS06447504

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 4, 2006
- Submitted: August 2, 2006
- Operation: Air carrier
- Aircraft: [N676UP](https://openairdocs.org/aircraft/N676UP), registered now
- Make and model: Boeing 747123F
- Aircraft serial: 20101
- Aircraft time: 83,907 hours, 23,132 cycles
- System (JASC): [5315 · Fuselage Main, Floor Beam](https://openairdocs.org/jasc/5315)
- Part: Floorbeam
- Condition: Corroded
- Location: Fuselage
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UPS06447504

## Discrepancy

AFT CARGO COMPT RT STA1600 IN BETWEEN RBL 32 TO RBL45 FLOORBEAM UPPER CHORD FOUND CORROSION.  CORROSION BLEND OUT 0.030" BY 1" BY 2".  AFT CARGO COMPT RT STA1600 COR BLEND OUT OF LIMIT UPPER CHORD FROM RBL 36-38 REPAIRED AS PER SRM 51-40-04 FIG 2 RBL32-36 AND RBL38-45 REPAIRED AND REPROTECTED AS PER SRM 51-10-01 AND 51-10-02 OR THICKNESS 0.088 DEPTH 0.006" WIDTH 1" AND LENGTH 7" WITHIN SRM 53-10-01 FIG1 LIMITATION.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.