# SDR UPS06447507

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 4, 2006
- Submitted: August 2, 2006
- Operation: Air carrier
- Aircraft: [N676UP](https://openairdocs.org/aircraft/N676UP), registered now
- Make and model: Boeing 747123F
- Aircraft serial: 20101
- Aircraft time: 83,907 hours, 23,132 cycles
- System (JASC): [5315 · Fuselage Main, Floor Beam](https://openairdocs.org/jasc/5315)
- Part: Floorbeam
- Condition: Corroded
- Location: Fuselage
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UPS06447507

## Discrepancy

AFT CARGO COMPT LT STA1820 IN BETWEEN LBL 12 AND LBL 24 FLOORBEAM UPPER CHORD FOUND CORROSION.  CORROSION BLEND OUT 0.025" BY 1.5" BY 2".  AFT CARGO COMPT BS 1820 LBL 12.5 TO LBL 14 AREA FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 51-40-04 FIG2 AND FLOORBEAM UPPER CHORD LBL14 TO LBL24 AREA CORROSION.  REMOVED AND REPROTECTED AS PER SRM 51-10-01 AND 51-10-02 BLEND OUT DEPTH 0.005" WIDTH 1/2" LENGTH 10" WITHIN SRM 53-10-01 FIG1 LIMITATION.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.