# SDR UPS06848794

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 20, 2006
- Submitted: December 22, 2006
- Operation: Air carrier
- Aircraft: N801UP
- Make and model: Doug DC-8-73F
- Registry model: [Doug DC-8-73F](https://openairdocs.org/model/douglas-dc-8-73f) (OpenAirDocs)
- Aircraft serial: 46101
- System (JASC): [2897 · Fuel System Wiring](https://openairdocs.org/jasc/2897)
- Part: Connector
- Condition: Broken
- Location: Nr 1 Main Tank
- Stage of operation: AP
- How discovered: O
- Nature of condition: X
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UPS06848794

## Discrepancy

INSPECTION TYPE:N/A ON FINAL APPROACH NR 1 ENGINE FLAMED OUT.  CROSSFEED LEVERS OPENED, ENGINE RELIT IMMEDIATELY.  TAXIING IN NR 1 ENGINE FLAMED OUT AGAIN.  (BOOST PUMP OFF) FUEL IN NR 1 MAIN 2000 LBS.  FOUND CONNECTOR TO NR 1 MAIN TANK FILL VALVE BROKEN.  REPLACED CONNECTOR IAW SDM 28-20-01.  OPS CHECK GOOD.  POWER FOR INTERMEDIATE FILL VALVE RUNS THROUGH SAME PLUG, GROUND RAN A/C AT VARIOUS POWER SETTINGS WITH BOOST PUMP OFF, DOWN TO 1700 LBS OF FUEL.  OK FOR CONTINUED SERVICE.

---