# SDR UPS08852991

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 5, 2008
- Submitted: August 12, 2008
- Operation: Air carrier
- Aircraft: N874UP
- Make and model: Doug DC-8-73F
- Registry model: [Doug DC-8-73F](https://openairdocs.org/model/douglas-dc-8-73f) (OpenAirDocs)
- Aircraft serial: 46074
- System (JASC): [2910 · Hydraulic System, Main](https://openairdocs.org/jasc/2910)
- Part: Fitting
- Condition: Inoperative
- Location: Hyd System
- Stage of operation: CR
- How discovered: O
- Nature of condition: K, J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UPS08852991

## Discrepancy

IN CRUISE, HYD QTY DROPPING RUN CK LIST, STOPPED AT AUX PUMP LEVEL. PRESS NEVER BELOW 3000 PSI.  R/R HYD FITTING AT LT MLG AFT HYD MANIFOLD, FAR OB POS FOR BOGIE TR TRIM CYL. REPACKED FITTING W/REF TO AMM 2-13-00-2. SERVICED MAIN HYD RESERVIOR W/REF TO AMM 12-30-01-3.  NO LEAKS NOTED.  OK FOR SERVICE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.