# SDR UPS08M54232

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 22, 2008
- Submitted: December 30, 2008
- Operation: Air carrier
- Aircraft: N296UP
- Make and model: Doug MD-11F
- Registry model: [Doug MD-11F](https://openairdocs.org/model/mcdonnell-douglas-md-11f) (OpenAirDocs)
- Aircraft serial: 48474
- System (JASC): [2565 · Escape Slide](https://openairdocs.org/jasc/2565)
- Part: Bottle
- Part number: 60289115
- Part serial: 0366
- Condition: Low Pressure
- Location: Evac Slide
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UPS08M54232

## Discrepancy

INSPECTION TYPE:N/A L1 DOOR SLIDE'S BOTTLE PRESSURE IS LOW PER TEMPERATURE COMPENSATED GREEN BAND ON GAUGE PRESSURE SWITCH IS CLOSED DUE TO LOW PSI.  REPLACED L1 DOOR SLIDE ASSY IAW MD-11 MM 25-61-01-4.  THIS CLEARS M-391314.  PLACARD REMOVED.

---