# SDR UPS97222167

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 27, 1997
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: [N903UP](https://openairdocs.org/aircraft/N903UP), registered now
- Make and model: Boeing 727-51C
- Registry model: [Boeing 727-51C](https://openairdocs.org/model/boeing-727-51c) (OpenAirDocs)
- Aircraft serial: 18945
- System (JASC): [2612 · Fire Detection](https://openairdocs.org/jasc/2612)
- Part: Fire Contl Box
- Condition: Inoperative
- Location: Nr 1 Strut
- Stage of operation: DE
- Nature of condition: N
- Precautionary procedure: E
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UPS97222167

## Discrepancy

INSPECTION TYPE-NA, DURING DESCENT FROM 250 TO 240 NR 1 ENG STRUT OVERHEAT LIGHT ILLUMINATED WITH THROTTLE APPROX ONE-THIRD FORWARD.  STRUT OVERHEAT CHEKLIST ACCOMPLISHED, LIGHT REMAINED ILLUMINATED AND NR 1 ENG SHUT DOWN.  REMOVED AND REPLACED FIRE DETECTOR CONTROL BOX PER MM 26-14-00 AND PERFORMED OPS, CK GOOD.  TIGHTENED ALL CONNECTORS, NO FURTHER FAULT FOUND.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.