## Discrepancy

INSPECTION TYPE:N/A, AFTER MORE INVESTIGATION FOUND DURING CRUISE ACFT HAD ERRATIC HYD SYSTEM PRESSURE FOLLOWED BY HYD FLUID LOSS DOWN TO STANDPIPE FLUID.  DECLARED EMERGENCY, LANDING IN SDF WAS UNEVENTFUL.  OBTAINED FLAPS 3 5 FOR LDG AND NORMAL GEAR FREE FALL.  MX FOUND HYDRAULIC RUDDER PRESSURE SWITCH LEAKING AT 3 FITTINGS.  UNION SECURED ALL FITTINGS AND REMOVED AND REPLACED O-RING AT UNION BB08473 2. OPS AND LEAK CHECKS GOOD PER MM 29-30-07.

---