# SDR USAA20090929EM068

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 29, 2009
- Submitted: September 29, 2009
- Operation: Air carrier
- Aircraft: N948UW
- Make and model: Emb ERJ 190-100 IGW
- Registry model: [EMB ERJ 190-100 IGW](https://openairdocs.org/model/embraer-erj-190-100-igw) (OpenAirDocs)
- Aircraft serial: 19000081
- System (JASC): [2560 · Emergency Equipment](https://openairdocs.org/jasc/2560)
- Part: Striker
- Part number: FE374150000
- Condition: Inoperative
- Location: L1 Door
- Stage of operation: IN
- How discovered: C
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/USAA20090929EM068

## Discrepancy

PIT - DURING THE EVACUATION SLIDE FUNCTIONAL TEST THE L1 DOOR ONLY PARTIALLY OPENED, COULD NOT OPEN OR CLOSE UNTIL THE ASSIST BOTTLE WAS DRAINED.  MAINTENANCE REMOVED AND REPLACED THE STRIKER ASSEMBLY.  PER CMM 52-11-51, THE DOOR ASSIST OPERATIONAL CHECK IS SATISFACTORY.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.