# SDR USAA2011072100013

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 27, 2011
- Submitted: July 21, 2011
- Operation: Air carrier
- Aircraft: [N723UW](https://openairdocs.org/aircraft/N723UW), registered now
- Make and model: Airbus A319-112
- Registry model: [Airbus A319-112](https://openairdocs.org/model/airbus-industrie-a319-112) (OpenAirDocs)
- Aircraft serial: 1109
- Aircraft time: 33,802 hours, 18,744 cycles
- System (JASC): [5321 · Fuselage Floor Panel](https://openairdocs.org/jasc/5321)
- Part: Floor Panel
- Part number: D5361060500100
- Condition: Corroded
- Location: Fuselage
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/USAA2011072100013

## Discrepancy

2S CHECK - CORROSION ON FLOOR PANEL 222FF BETWEEN FR16 TO FR20, S23R.  REPLACED FLOOR PANEL 222FF IAW A319 AMM  53-42-12.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.