# SDR USAASA02116

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 27, 2002
- Submitted: January 14, 2003
- Operation: Air carrier
- Aircraft: [N748UW](https://openairdocs.org/aircraft/N748UW), registered now
- Make and model: Airbus A319-112
- Registry model: [Airbus A319-112](https://openairdocs.org/model/airbus-industrie-a319-112) (OpenAirDocs)
- Aircraft serial: 1311
- System (JASC): [3350 · Emergency Lighting](https://openairdocs.org/jasc/3350)
- Part: Power Supply
- Part number: 32145410
- Condition: Discharged
- Location: Cabin
- Part time: 7,222 hours
- Stage of operation: IN
- How discovered: C
- Nature of condition: L
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/USAASA02116

## Discrepancy

TPA - THE CABIN INTERCOMMUNICATIONS DATA SYSTEM EMERGENCY LIGHT TEST GAVE "EPSU R FAULT" MESSAGE.  MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT, FIN 12WL.  OPERATIONALLY CHECKS OK.  (M)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.