# SDR V0XR20230216AV3

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 23, 2022
- Submitted: February 16, 2023
- Operation: General aviation
- Filed by: [Avmax Montana, Inc, repair station V0XR413Y](https://openairdocs.org/faa-repair-station/V0XR413Y/avmax-montana-inc.md) (OpenAirDocs)
- Aircraft: N15574
- Make and model: Emb EMB-145LR
- Registry model: [EMB EMB-145LR](https://openairdocs.org/model/embraer-emb-145lr) (OpenAirDocs)
- Aircraft serial: 145639
- System (JASC): [5743 · Wing, Landing Gear Attach Fittings](https://openairdocs.org/jasc/5743)
- Part: Trunnion
- Part number: 14566000437
- Part serial: 641
- Condition: Corroded
- Location: Zone 500
- Part time: 41,172 hours, 32,557 cycles
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/V0XR20230216AV3

## Discrepancy

LEFT MLG TRUNNION IS CORRODED REPAIRED IAW EMBRAER ETD2022-145-038071

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.