## Discrepancy

THE HYD EDP 2A CAUTION MESSAGE ILLUMINATED ONE MINUTE PRIOR TO LANDING AT CLT.  MAINTENANCE DEFERRED THE NR 2 ENGINE DRIVEN HYDRAULIC PUMP AND COMPLIED WITH THE M FUNCTION IAW CRJ700 MEL 29-11-01-2, CODE A.  THE AIRCRAFT WAS THEN RELEASED FOR SERVICE.  ON 07/22/05 MAINTENANCE CLEARED THE MEL BY INSTALLING A SERVICEABLE UNIT ON THE NR 2 ENGINE IAW CRJ700 AMM 29-11-01-400-801-A01.  OPERATIONAL AND LEAK CHECKS WERE GOOD.  THE AIRCRAFT WAS AGAIN RELEASED FOR SERVICE.

---