# SDR VNAA2015102200020

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 22, 2015
- Submitted: October 26, 2015
- Operation: Air carrier
- Aircraft: [N226JS](https://openairdocs.org/aircraft/N226JS), registered now
- Make and model: Cndair CL6002B19
- Aircraft serial: 7895
- Aircraft time: 28,561 hours, 28,644 cycles
- System (JASC): [2150 · Cabin Cooling System](https://openairdocs.org/jasc/2150)
- Part: Regulator Valve
- Part number: 32156222
- Part serial: 2049
- Condition: Failed
- Location: Air Conditioning
- Part time: 27,202 hours, 25,884 cycles
- Stage of operation: CL
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/VNAA2015102200020

## Discrepancy

CREW REPORTED RT PACK SHUTOFF WHEN BLEEDS TRANSFERRED FROM APU TO ENGINE.  CREW RETURNED TO FIELD AND LANDED WITHOUT INCIDENT.  MAINTENANCE TROUBLESHOT, R & R RT AIR CONDITIONING PRESSURE REGULATING AND SHUTOFF VALVE AND PERFORMED CHECKS IAW AMM.  ACFT RELEASED FOR SERVICE.

---