- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 14, 2017
- Submitted: November 1, 2017
- Operation: Air carrier
- Aircraft: [N630VA](https://openairdocs.org/aircraft/N630VA), registered now
- Make and model: Airbus A320-214
- Registry model: [Airbus A320-214](https://openairdocs.org/model/airbus-a320-214) (OpenAirDocs)
- Aircraft serial: 3101
- System (JASC): [2400 · Electrical Power System](https://openairdocs.org/jasc/2400)
- Part: Control Unit
- Part number: 1700667D
- Condition: Failed
- Stage of operation: NR
- How discovered: 9
- Nature of condition: B
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/VQI20201711010053

## Discrepancy

THE FLIGHT CREW REPORTED AN ELECTRICAL BURNING ODOR IN THE FLIGHT DECK,  ASSOCIATED WITH POWER TRANSFER BETWEEN GROUND AND APU ELECTRICAL POWER.  DURING TROUBLESHOOTING THE GAPCU UNIT WAS DISCOVERED FAILED, THE UNIT WAS REPLACED AND THE AIRCRAFT WAS RETURNED TO SERVICE.   INSPECTION FOR ELECTRICAL ODORS WAS ACCOMPLISHED WITH NO FINDINGS IAW AMM-24-0 0-00-810.  NO REPORTS OF ODOR ON SUBSEQUENT FLIGHTS.

---