# SDR WRLA200410

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 28, 2004
- Submitted: March 6, 2004
- Operation: Air carrier
- Aircraft: N303WL
- Make and model: Doug DC-10-30F
- Registry model: [Doug DC-10-30F](https://openairdocs.org/model/mcdonnell-douglas-dc-10-30f) (OpenAirDocs)
- Aircraft serial: 46917
- System (JASC): [2131 · Cabin Pressure Controller](https://openairdocs.org/jasc/2131)
- Part: Controller
- Condition: Intermittent
- Location: A/C Pack
- Component: A/C Pack, Garrettltd
- Component part number: 6179246
- Stage of operation: CL
- How discovered: C
- Nature of condition: B, J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/WRLA200410

## Discrepancy

SMOKE IN COCKPIT AFTER TAKE OFF TURNED NR 2  PACK OFF. SMOKE STOPED.RETURNED TO BGR.  NOTE INSPECTED PACK & ON OPS TEMP DISCHARGE TEMP 95 PERCENT PACK AUTO OFF PLACED NR 2 PACK ON DMI M21FE2704-124 MEL 21-1 CAT C.. CLEARED DMI M21FE2704 REMOVED AND REPLACED NR 2 PACK TEMP CONTROLLER RAN NR 2 PACK ON GROUND FOR MAINY HOURS & PACK TEMP OPS NORMAL ALL PARAMETERS SHOW NORMAL AT THIS TIME ON GROUND.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.