# SDR WRNA00023

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 13, 2001
- Submitted: August 23, 2002
- Operation: Air carrier
- Aircraft: [N311EA](https://openairdocs.org/aircraft/N311EA), registered now
- Make and model: Lkheed 10113851
- Aircraft serial: 193A1012
- Aircraft time: 55,436 hours, 24,975 cycles
- System (JASC): [2170 · Humidity Control System](https://openairdocs.org/jasc/2170)
- Part: Cover
- Part number: 7339308
- Condition: Out Of Position
- Location: A/C Bay
- Stage of operation: CR
- How discovered: O
- Nature of condition: O
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/WRNA00023

## Discrepancy

AT 27,000 FEET NR 2 PACK WATER SEPARATOR COVER BLEW OFF.  CREW UNABLE TO MAINTAIN PRESSURIZATION ON NR 3 PACK ONLY.  AIRCRAFT RETURNED TO BQN.  FUEL DUMPED.  AIRCRAFT LANDING NORMAL.  WATER SEPARATOR COVER REINSTALLED, CLAMP SECURED AND TORQUED IAM MM 21-51-07.  OPERATIONAL CHECK AND LEAK CHECK PERFORMED.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.