# SDR WVER2013F00108

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: May 3, 2013
- Submitted: May 4, 2013
- Operation: General aviation
- Filed by: [MHI RJ Aviation Inc, repair station WVER835K](https://openairdocs.org/faa-repair-station/WVER835K/mhi-rj-aviation-inc.md) (OpenAirDocs)
- Aircraft: [N906FJ](https://openairdocs.org/aircraft/N906FJ), registered now
- Make and model: Cndair CL6002D24
- Aircraft serial: 15006
- Aircraft time: 25,122 hours, 19,921 cycles
- System (JASC): [2497 · Electrical Power System Wiring](https://openairdocs.org/jasc/2497)
- Part: Feeder Cable
- Part number: M850495322W
- Condition: Corroded
- Location: Adg
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/WVER2013F00108

## Discrepancy

ADG POWER FEEDER WIRES SILVER PLATING CAN BREAK DOWN IN AREAS OF TIGHT WIRING RADIUS'S, WHICH CAN LEAD TO CORROSION ON ALL OR A MAJORITY OF WIRE STRANDS.

---