## Discrepancy

CREW WORKING ELECTRICAL PROBLEM ON LT BUSS USING COM W/APU STARTED & RUNNING.  APU LOW OIL PRESSURE LIGHT & OIL TEMP HIGH LIGHT ILLUM.  APU SHUTDOWN.  A/C OPS ON NR 2 GEN & BATTERIES.  AN EMERGENCY DECLARED, A/C GIVEN DIRECT TO SDF & VECTORED FOR APPROACH.  AIRCRAFT LANDED WITHOUT FURTHER INCIDENT AT SDF.  NR 2 GENERATOR REMAINED OPERABLE DURING DESCENT AND LANDING.  MANTENANCE DISPATCHED TO SDF FOUND THE APU OIL REQUIRED SERVICING.  APU OIL WAS SERVICED AND THE SYSTEM THEN CHECKED GOOD IAW DC-9 MM 49-10-0.  LT GENERATOR SYS THEN OPERATIONALLY CHECKED GOOD IAW THE DC-9 MM 24-20-6.  THE AIRCRAFT WAS RETURNED TO SERVICE.  (M)

---