# SDR YENA20090616062

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 15, 2009
- Submitted: June 16, 2009
- Operation: Air carrier
- Aircraft: [N184JB](https://openairdocs.org/aircraft/N184JB), registered now
- Make and model: Emb ERJ 190-100 IGW
- Registry model: [EMB ERJ 190-100 IGW](https://openairdocs.org/model/embraer-erj-190-100-igw) (OpenAirDocs)
- Aircraft serial: 19000008
- Aircraft time: 9,843 hours, 6,155 cycles
- System (JASC): [3620 · Pneumatic Indicating System](https://openairdocs.org/jasc/3620)
- Part: Sensor
- Part number: 0490005099A
- Condition: Failed
- Location: Bleed Air Sys
- Part time: 9,843 hours, 6,155 cycles
- Stage of operation: CR
- How discovered: O
- Nature of condition: N
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/YENA20090616062

## Discrepancy

FLT 462, RSW-BOS - THE BLEED 2 LEAK MSG APPEARED ALONG WITH LEAK ROW ON 2 BUTTON.  RAN QRH, ALL INDICATIONS REMAINED THE SAME.  DIVERTED TO MCO.  PERFORMED FIM TASK 36-21-00-810-804A, FOUND FAILURE OF LEAK DETECTOR LOOP 5 SEGMENT 1RT0186 CHANNEL 1.  REMOVED & REPLACED LEAK SENSOR PER AMM 36-21-02, OPS CHECKS OK.  MESSAGE CLEARED.

---