AIR RETURN DUE TO BLEED 2 LEAK MESSAGE AFTER TAKEOFF.  QRH COMPLIED WITH, MESSAGE WENT AWAY AFTER 3 MINUTES. THEN BLEED 2 LEAK MESSAGE RETURNED WITH BLEED 2 OFF.  BLEED 1 TURNED OFF IAW QRH.  BLEED 2 MESSAGE WAS INTERMITTENT THOUGH ALL BLEEDS WERE OFF.  QRH ISOLATION STEPS LED TO ACFT BEING UNPRESSURIZED.  DURING TROUBLESHOOTING FOUND CONNECTOR P2146 WITH A BROKEN PIN.  R & R CONNECTOR P2146 (CH1) IAW CMM 26-14-53.  OP'S CHECK GOOD. PERFORMED LEAK CHK AT RT BLEED LINES.  NO LEAKS NOTED OR FAULTS NOTED DURING HIGH POWER RUN.

---