# SDR YENA201702130070

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 13, 2017
- Submitted: February 16, 2017
- Operation: Air carrier
- Aircraft: N353JB
- Make and model: Emb ERJ 190-100 IGW
- Registry model: [EMB ERJ 190-100 IGW](https://openairdocs.org/model/embraer-erj-190-100-igw) (OpenAirDocs)
- Aircraft serial: 19000576
- Aircraft time: 12,919 hours, 8,512 cycles
- System (JASC): [2910 · Hydraulic System, Main](https://openairdocs.org/jasc/2910)
- Part: Bleed Valve
- Part number: 2327H030
- Part serial: 3620
- Condition: Failed
- Location: Hydraulic Sys
- Part time: 7,257 hours, 4,863 cycles
- Stage of operation: CR
- How discovered: O
- Nature of condition: K, J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/YENA201702130070

## Discrepancy

FT 1170, MCO-RIC, RETURN TO FIELD. ENROUTE, CREW REPORTED SYSTEM 2 HYDRAULICS INDICATED LOW QUANTITY ON EICAS, QUANTITY DROPPED TO 0; FOUND NR 2 HYD SYS FOUND RESERVOIR ECOLOGY BOTTLE OVERFLOWING. R&R HYD SYS RESERVOIR RELIEF/BLEED/SAMPLE VALVE IAW AMM 29-11-10. LEAK WAS RESOLVED. OPS CHECK PASSED.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.