# SDR YENA2026100500927

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 3, 2026
- Submitted: October 6, 2026
- Operation: Air carrier
- Aircraft: [N3138J](https://openairdocs.org/aircraft/N3138J), registered now
- Make and model: Airbus BD-500-1A11
- Registry model: [Airbus BD-500-1A11](https://openairdocs.org/model/airbus-canada-lp-bd-500-1a11) (OpenAirDocs)
- Aircraft serial: 55222
- Aircraft time: 8,441 hours, 3,842 cycles
- System (JASC): [3010 · Airfoil Anti/De-ice System](https://openairdocs.org/jasc/3010)
- Part: Anti-Ice Valve
- Condition: Faulted
- Stage of operation: CR
- How discovered: V
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/YENA2026100500927

## Discrepancy

FLT 2895, BOS-PUJ-RTF. REF. DEFECT  4559648 ITEM 1 RIGHT WING ANTIICE VALVE REQ'D OPS CHECK AND ENG HIGH POWER RUN.; PERFORMED OPS CHECK & HIGH POWER RUN IAW AMP 30-12-01 ALL OPS NORMAL AT THIS TIME A/C IS OK FOR SERVICE .

---