# SDR ZZDA2008035

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 20, 2008
- Submitted: January 21, 2008
- Operation: Air carrier
- Aircraft: [N965AT](https://openairdocs.org/aircraft/N965AT), registered now
- Make and model: Boeing 717-200
- Registry model: [Boeing 717-200](https://openairdocs.org/model/boeing-717-200) (OpenAirDocs)
- Aircraft serial: 55026
- System (JASC): [3810 · Potable Water System](https://openairdocs.org/jasc/3810)
- Part: Line
- Condition: Leaking
- Location: Galley
- Stage of operation: CR
- How discovered: O
- Nature of condition: K, B
- Precautionary procedure: B
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/ZZDA2008035

## Discrepancy

SMOKE AND ACID SMELL IN COCKPIT.  PUFF AND ELECTRICAL SMELL GALLEY AREA IE COFFEE POTS REPORTED BY A FLIGHT ATTENDANT.  FOUND WATER LEAK IN GALLEY DRIPPING ON NR 3 COFFEEMAKER CONNECTOR CAUSING A SHORT AND SMALL AMOUNT OF SMOKE.  REPLACED WATER SUPPLY LINE.  REF M/M 38-10.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.