# Air Comm Service Bulletin 429-201-1

Copy: Revision NC ("Air Comm Corp SB 429-201-1 Rev NC Released"), 3 pages: PDF https://openairdocs.org/files/sha256/63/c9/63c906d46b5e3a6e42332dfdaea08207d5a21a472adf4721a47c9deb4336206d; text https://openairdocs.org/service-documents/air-comm/sb-429-201-1/file/63c906d46b5e.md. Rights: © Air Comm. Filed by the FAA in regulations.gov docket FAA-2017-0189; AD 2017-05-51 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Air Comm](https://openairdocs.org/service-documents/air-comm.md)
- Type: Service bulletin (Service Bulletin)
- Number: 429-201-1
- Latest revision known: 429-201-1, Revision NC, dated February 17, 2017 (OpenAirDocs)
- Page: https://openairdocs.org/service-documents/air-comm/sb-429-201-1

## ADs that cite it (1) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2017-05-51](https://openairdocs.org/ad/2017-05-51.md), effective Apr 25, 2017: Revision NC

## Text (3 pages)

Rights: © Air Comm. Filed by the FAA in regulations.gov docket FAA-2017-0189; AD 2017-05-51 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1 (OCR)

ACC  Page 1 of 3
Air Comm Corporation  SB 429-201-1
Rev NC
Service Bulletin
Title:  SB 429-201-1 Bell 429 Condenser Fan Motor Mount Fastener Inspection
Date:  February 17, 2017
Applicability:  Bell Helicopter Textron Canada Limited 429 Aircraft equipped with any Air
Comm Corporation 429EC-200 or 429EC-202 Air Conditioning Systems.
Reference:  FAA STC # SR00693DE
Compliance:  Recommended inspection within 20 flight hours.
Revision  Issue Date  Inserted By  Approved by Description of Changes
NC  2/17/17  CRP  L<13  Initial Release
A. Discussion:
During an annual inspection, an operator reported finding the condenser fan motor detached
from the condenser blower assembly and resting on the collective control tube. The condenser
fan motor is secured to the condenser blower assembly by 3 fasteners with thread locker
applied. Evidence suggests that some motor mount fasteners may have had misapplied thread
locker.
B. Procedure:
Follow the procedure listed below:
1. Locate and visually inspect the condenser fan motor securement. Refer to Figure 1 to
identify the three MS27039-1-15 fasteners mounting the condenser motor to the
condenser blower assembly.
2. If the condenser fan motor is not attached to the condenser blower assembly:
a. Report incident to ACC at: Phone 303-440-4075, Fax 303-440-6355, or E-mail
service@aircommcorp.com
b. Inspect surrounding area for damage. Repair and replace as required per Bell
maintenance instructions.
c. f replacement components are available, before next flight, replace condenser
blower assembly per 429EC-200M-1 Instructions for Continued Airworthiness
(ICA). Skip to step 5 of this procedure and log the completion of this service
bulletin.
d. If replacement components are not available, before next flight, DEACTIVATE air-
conditioning system per instructions below.
i. Pull and red collar the air-conditioning COND circuit breaker
ii. Pull and red collar the air-conditioning COMP circuit breaker.
ili. Remove the compressor drive belt per the ICA.
iV. Remove motor and cap and stow wiring harness.
v. Fan blade will be loose but will remain fully retained inside the shroud.
1575 West 124th Avenue, Westminster, CO 80234 • 303-440-4075
4554 Claire Chennault Street, Addison, TX 75001 • 972-407-1234
www.aircommcorp.com • info@aircommcorp.com

### Page 2

Page 2 of 3 
SB 429-201-1 
Rev NC 
1575 West 124th Avenue, Westminster, CO 80234 • 303-440-4075 
4554 Claire Chennault Street, Addison, TX 75001 • 972-407-1234 
  www.aircommcorp.com • info@aircommcorp.com 
 
vi. Make log entry that the air-conditioning system is DEACTIVATED per ACC 
service bulletin SB 429-201-1. 
vii. Skip to step 5 of this procedure and log the completion of this service 
bulletin. 
3. If any MS27039-1-15 fasteners are missing or loose or the condenser fan motor is not 
firmly secure to the condenser blower assembly: 
a. Report the incident to ACC at: Phone 303-440-4075, Fax 303-440-6355, or E-mail 
service@aircommcorp.com 
b. Inspect surrounding area for damage. Repair and replace as required per Bell 
maintenance instructions. 
c. Visually inspect the fan shroud for damage. 
d. Rotate the fan blades by hand and verify clearance between the blades and the 
shroud. 
e. If the fan blades are scraping or rubbing against the shroud or there is visible 
damage to the fan shroud from the blades. 
i. If replacement components are available, before next flight, replace 
condenser blower assembly per 429EC-200M-1 Instructions for Continued 
Airworthiness (ICA). Skip to step 5 of this procedure and log the 
completion of this service bulletin. 
ii. If replacement components are not available, before next flight, 
DEACTIVATE air-conditioning system per instructions below. 
a) Pull and red collar the air-conditioning COND circuit breaker. 
b) Pull and red collar the air-conditioning COMP circuit breaker. 
c) Remove the compressor drive belt per the ICA. 
d) Secure motor per step 4 of this section. 
e) Make log entry that the air-conditioning system is DEACTIVATED 
per ACC service bulletin SB 429-201-1. 
4. Replace missing fasteners and remove and reinstall existing fasteners as follows: 
a. Clean the threads of the fastener of any debris and/or existing thread locker 
residue. 
b. If no thread locker is found on existing fasteners, report incident to ACC at: Phone 
303-440-4075, Fax 303-440-6355, or E-mail service@aircommcorp.com 
c. Apply Loctite 222 to the fastener threads and re-install fastener with 20 to 25 in-lbf 
torque.  
d. Once all fasteners are secure, apply torque stripe to the head of each fastener. 
e. Allow a minimum of 6 hours for Loctite to cure prior to aircraft flight operations. 
5. Make log entry that this service bulletin SB 429-201-1 has been performed.

### Page 3

Page 3 of 3 
SB 429-201-1 
Rev NC 
1575 West 124th Avenue, Westminster, CO 80234 • 303-440-4075 
4554 Claire Chennault Street, Addison, TX 75001 • 972-407-1234 
  www.aircommcorp.com • info@aircommcorp.com 
 
 
Figure 1 
 
C. Approval: 
This bulletin is based on previously FAA-approved data. 
 
D. Weight & Balance: 
Changes to weight & balance as a result of this service bulletin has been determined to be 
negligible. 
 
 
 
 
 
Three MS27039-1-15 
fasteners with 
NAS1149F0332P washers

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.