Copy: No revision named ("SB B500-252061"), 40 pages: PDF https://openairdocs.org/files/sha256/55/c5/55c524d831c17b5def4a9e602b6a38ed514cf36018d71e9c6be82c0468e93ea5; text https://openairdocs.org/service-documents/airbus-canada/b500-252061/file/55c524d831c1.md. Rights: © Airbus Canada Limited Partnership. Filed by the FAA in regulations.gov docket FAA-2025-2547, the docket of AD 2026-07-04. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Airbus Canada](https://openairdocs.org/service-documents/airbus-canada.md)
- Type: Service bulletin (Service Bulletin)
- Number: B500-252061
- Page: https://openairdocs.org/service-documents/airbus-canada/b500-252061

## Text (40 pages)

Rights: © Airbus Canada Limited Partnership. Filed by the FAA in regulations.gov docket FAA-2025-2547, the docket of AD 2026-07-04. Not covered by OpenAirDocs’ CC0 dedication. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

BD500-252061
 
Inspection of the Overhead Storage
Compartment (OHSC) Tie-Rod Assemblies -
Accomplishment instruction
BD500-252061
Issue No. 001.00
Copyright © Airbus Canada Limited Partnership
All rights reserved. No part of this work may be reproduced or copied in any form or by any means without written permission of Airbus
Canada Limited Partnership.
The Airbus and A220 logos are registered trademarks of Airbus Canada Limited Partnership.
The information, technical data and the designs disclosed herein are the exclusive property of Airbus Canada Limited Partnership or contain
proprietary rights of others and are not to be used or disclosed to others without the written consent of Airbus Canada Limited Partnership. The
recipient of this document, by its retention and use, agrees to hold in confidence the technical data and designs contained herein. The foregoing
shall not apply to persons having proprietary rights to such information, technical data or such designs to the extent that such rights exist.
Publication No.:
Manufacturer:
Airbus Canada Limited Partnership
Customer Services
13100 Henri-Fabre Blvd.
Mirabel, Quebec J7H 3C6
  Page  1
2025/02/20

### Page 2

Intentionally left blank
  Page  2
2025/02/20

### Page 3

BD500-252061
Equipment/Furnishings - Passenger/Operating Crew
Compartment - Inspection of the Overhead Storage
Compartment (OHSC) Tie-Rod Assemblies - Service Bulletin
References
Table 1 References
Data Module/Technical Publication Title
BD500-A-J25-20-61-01AAA-933A-A Inspection of the Overhead Storage Compartment
(OHSC) Tie-Rod Assemblies - Accomplishment
instruction
Service Bulletin
Common information
THIS SERVICE BULLETIN IS SENT TO EACH OPERATOR. IF THE OPERATOR HAS
LEASED AIRCRAFT, SEND THE SERVICE BULLETIN TO THE LESSEE. IF THE OPERATOR
HAS SOLD AIRCRAFT OR TRANSFERRED SPARES IN THE LAST SIX MONTHS, SEND
THIS SERVICE BULLETIN TO THE NEW OWNER, UNLESS CONFIRMATION WAS
RECEIVED THAT AIRBUS HAS INCLUDED THE NEW OPERATOR ON THE DISTRIBUTION
LIST.
Management information
Compliance category: Mandatory (Service bulletin must be accomplished)
Task category: Inspection and repair
Original issue date: 2025-02-20
Impact list
None
Accomplishment limits
Time compliance: Basic limit
Remarks:
Refer to the Compliance section of the Planning Information section.
Replacement service bulletin
None
Revision information
Initial issue
See applicability on the first page of the DM
BD500-A-J25-20-61-00AAA-930A-A (001)
BD500-A-J25-20-61-00AAA-930A-A (001)
 2025-02-20 Page  3

### Page 4

BD500-252061
Summary
Applicability
BD-500-1A10, Aircraft 50010 thru 50018, 50020 thru 50061, and 50063 thru 50065
BD-500-1A11, Aircraft 55003 thru 55016 and 55018 thru 55172
Reason
It is possible that the Overhead Storage Compartment (OHSC) tie-rod assemblies were installed
without the threads of the clevis correctly engaged in the turnbuckle of one end of the tie
rod assemblies. This can have an unwanted effect on the integrity of the OHSCs during an
emergency landing.
Description
The aircraft is put in standard configuration for maintenance. Some ceiling panels are removed.
An inspection of the tie rod assembly of each OHSC is done. If necessary, the tie rod
assembly is disconnected from the structure, adjusted, and installed to the structure again.
Some ceiling panels are installed.
Concurrent requirements
None
Manpower
It will take an estimated 11.5 h to complete this service bulletin.
Material information
Refer to the different data modules that are given as references in this service bulletin.
Planning information
Applicability
Aircraft affected:
AIRCRAFT MODEL SERVICE AIRCRAFT SERIAL
NUMBER
PRODUCTION AIRCRAFT
SERIAL NUMBERS
BD-500-1A10 50010 thru 50018, 50020 thru
50061, and 50063 thru 50065
There is no production
effectivity.
BD-500-1A11 55003 thru 55016 and 55018
thru 55172
There is no production
effectivity.
Note
The instructions in this service bulletin are only applicable to the systems and parts
installed at the time of delivery of the aircraft or as changed by Airbus Service Bulletins.
Before you do this service bulletin, examine all Supplemental Type Certificates (STCs),
Supplemental Type Approvals (STAs), or equivalent action changes to make sure that you
can complete this service bulletin.
See applicability on the first page of the DM
BD500-A-J25-20-61-00AAA-930A-A (001)
BD500-A-J25-20-61-00AAA-930A-A (001)
 2025-02-20 Page  4

### Page 5

BD500-252061
Reason
Problem and effect
It is possible that the OHSC tie-rod assemblies were installed without the threads of the clevis
correctly engaged in the turnbuckle of one end of the tie rod assemblies. This can have an
unwanted effect on the integrity of the OHSCs during an emergency landing.
Objective/Solution
This service bulletin gives the procedure to do an inspection, and if necessary, an adjustment
of the tie rod assemblies to make sure that the threads of the clevis are correctly engaged in
the turnbuckle. This will prevent an unwanted effect on the integrity of the OHSCs during an
emergency landing.
Description
The aircraft is put in standard configuration for maintenance. Some ceiling panels are removed.
An inspection of the tie rod assembly of each OHSC is done. If necessary, the tie rod
assembly is disconnected from the structure, adjusted, and installed to the structure again.
Some ceiling panels are installed.
Compliance
Mandatory Service Bulletin
Airbus recommends that this service bulletin be done no later than 4 years from the release
date of this service bulletin, unless otherwise directed by the airworthiness authority of the
operator.
Note
If it is not possible to complete all the instructions in this service bulletin because of
the configuration of the aircraft, speak with a CRC representative at 1 866 A220 CRC
(1-866-222-0272) or 1-450-476-7676 or e-mail at a220crc@airbus.com for analysis and to
get an approved disposition to complete this service bulletin.
Note
This service bulletin does not affect Airworthiness Limitations Items (ALIs) or Damage
Tolerance Inspections (DTIs).
Concurrent requirements
None
Approval
The technical content of this service bulletin has been approved under the authority of the
TCCA Design Approval Organization No: DAO #19-Q-02.
Manpower
The man-hours given below are estimates for direct labor done by an experienced crew on an
aircraft prepared for maintenance.
These estimates do not include the time necessary for:
‐ Administrative functions such as planning, liaising, familiarization, and report writing.
‐ Non-productive elapsed time such as rest time, having meals, and crew shift changes.
See applicability on the first page of the DM
BD500-A-J25-20-61-00AAA-930A-A (001)
BD500-A-J25-20-61-00AAA-930A-A (001)
 2025-02-20 Page  5

### Page 6

BD500-252061
‐ Elapsed time such as for paint to dry, sealant to cure, and fuel tank venting.
‐ Preparation for modification (unless specified in the Accomplishment Instructions) such as
cleaning and getting parts, tools, consumables, and ground equipment.
‐ Quality assurance inspections, troubleshooting and/or correction of discrepancies found
when a task is done.
‐ All other activities that are not considered by Airbus as directly related to the
accomplishment of this procedure.
It will take an estimated 11.5 h to complete this service bulletin. The man-hours are divided as
shown in the table that follows:
TASK MAN-HOURS
Job Set-Up 1.0 h
Procedure 8.0 h
Test 0 h
Job Close-Up 2.5 h
Weight and balance
Not changed
Electrical load data
Not changed
Referenced documentation
Refer to the SB Introduction document BD500-000000 for definition or explanation of service
bulletin content.
For Airbus reference only: Restriction and/or Special Instruction (RSI) C-500-000-25-0075,
Revision C
For Airbus reference only: PCR 63239
Documentation affected
1 Maintenance Publications
None
2 Operational Publications
None
Industry support information
This service bulletin is part of an AIRBUS monitored retrofit campaign. For detailed information,
please refer to Retrofit Information Letter (RIL) S25M24001589. To organize this retrofit, please
contact AIRBUS retrofit management department at: a220monitored.retrofit@airbus.com.
See applicability on the first page of the DM
BD500-A-J25-20-61-00AAA-930A-A (001)
BD500-A-J25-20-61-00AAA-930A-A (001)
 2025-02-20 Page  6

### Page 7

BD500-252061
Material information
Refer to the different data modules that are given as references in this service bulletin.
Accomplishment instructions
BD500-A-J25-20-61-01AAA-933A-A
Additional information
None
See applicability on the first page of the DM
BD500-A-J25-20-61-00AAA-930A-A (001)
BD500-A-J25-20-61-00AAA-930A-A (001)
End of data module
 2025-02-20 Page  7

### Page 8

BD500-252061
Intentionally left blank
See applicability on the first page of the DM
BD500-A-J25-20-61-00AAA-930A-A (001)
BD500-A-J25-20-61-00AAA-930A-A (001)
 2025-02-20 Page  8

### Page 9

BD500-252061
Inspection of the Overhead Storage Compartment
(OHSC) Tie-Rod Assemblies - Accomplishment instruction
References
Table 1 References
Data Module/Technical Publication Title
BD500-A-J12-00-00-01AAA-398A-A Standard configuration for maintenance - Aircraft system
configuration
BD500-A-J25-29-03-01AAA-520A-A Passenger compartment ceiling panel - Remove
procedure
BD500-A-J25-29-03-01AAA-720A-A Passenger compartment ceiling panel - Install procedure
BD500-A-J25-29-03-04AAA-520A-A Forward right ceiling panel - Remove procedure
BD500-A-J25-29-03-04AAA-720A-A Forward right ceiling panel - Install procedure
BD500-A-J25-29-03-04ACA-520A-A Forward right ceiling panel - Remove procedure
BD500-A-J25-29-03-04ACA-720A-A Forward right ceiling panel - Install procedure
BD500-A-J25-29-03-05AAA-520A-A Forward left ceiling panel - Remove procedure
BD500-A-J25-29-03-05AAA-720A-A Forward left ceiling panel - Install procedure
BD500-A-J25-29-03-05ACA-520A-A Forward left ceiling panel - Remove procedure
BD500-A-J25-29-03-05ACA-720A-A Forward left ceiling panel - Install procedure
BD500-A-J25-29-03-06AAA-520A-A Aft right ceiling panel - Remove procedure
BD500-A-J25-29-03-06AAA-720A-A Aft right ceiling panel - Install procedure
BD500-A-J25-29-03-07AAA-520A-A Aft left ceiling panel - Remove procedure
BD500-A-J25-29-03-07AAA-720A-A Aft left ceiling panel - Install procedure
BD500-A-J25-29-03-08AAA-520A-A Ceiling panel - Transition Z3 and Z4 - Remove
procedure
BD500-A-J25-29-03-08AAA-720A-A Ceiling panel - Transition Z3 and Z4 - Install procedure
BD500-A-J25-29-03-09AAA-520A-A Ceiling panel - Remove procedure
BD500-A-J25-29-03-09AAA-720A-A Ceiling panel - Install procedure
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  9

### Page 10

BD500-252061
Preliminary requirements
Required conditions
Table 2  Required conditions
Action/Condition Data Module/Technical publication
None
Support equipment
Table 3  Support equipment
Name Identification/Reference Quantity Remark
None
Consumables, materials, and expendables
Table 4  Consumables, materials, and expendables
Name Identification/Reference Quantity Remark
None
Spares
Table 5  Spares
Name Identification/Reference Quantity Remark
None
Safety conditions
None
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  10

### Page 11

BD500-252061
Procedure
1 General information
Note
This service bulletin is classified as Mandatory or expected to be Mandatory by
an Airworthiness Directive (AD). The Procedure section of the Accomplishment
Instructions is Required for Compliance (RC) and must be done to comply with
the AD. The Job set-up and Job close-up sections, with the exception of the
return-to-service tests, are recommended and can be deviated from, done as part
of other actions, or done with accepted methods different from those given in the
service bulletin, as long as the RC section can be done and the aircraft can be
put back into a serviceable condition.
2 Job set-up
Note
The steps in the Job set-up section of this service bulletin are recommended
steps. The steps give a recommendation to get access to the work area. This
recommendation is to give a safe work area and to minimize possible damage to
surrounding aircraft parts. Alternative steps can be used at the discretion of the
operator.
2.1 Make sure that the aircraft is in standard configuration for maintenance (refer to
AMP BD500-A-J12-00-00-01AAA-398A-A).
Applicability: 50010-50018, 55010-55015, 55020-55021, 55023, 55025, 55027, 55029-55030, 55032-55033,
55036, 55040, 55044-55046, 55110
2.2 Remove the access panels that follow:
PANEL NAME REFERENCE
223CLC Ceiling panel AMP BD500-A-
J25-29-03-05ACA-520A-A
224CRC Ceiling panel AMP BD500-A-
J25-29-03-04ACA-520A-A
Applicability: 55003-55009, 55016, 55018-55019, 55022, 55024, 55026, 55028, 55031, 55034-55035,
55037-55039, 55041-55043, 55049
2.3 Remove the access panels that follow:
PANEL NAME REFERENCE
223CLC Ceiling panel AMP BD500-A-
J25-29-03-05AAA-520A-A
224CRC Ceiling panel AMP BD500-A-
J25-29-03-04AAA-520A-A
Applicability: 50010-50018, 55003-55016, 55018-55046, 55049, 55110
2.4 Remove the access panels that follow:
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  11

### Page 12

BD500-252061
PANEL NAME REFERENCE
233ALC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
234ARC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
233BLC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
234BRC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
233CLC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
234CRC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
233DLC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
234DRC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
233ELC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
234ERC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
233FLC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
234FRC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
243ALC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
244ARC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
Applicability: 55003-55016, 55018-55046, 55049, 55110
2.5 Remove the access panels that follow:
PANEL NAME REFERENCE
233GLC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
234GRC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  12

### Page 13

BD500-252061
PANEL NAME REFERENCE
233HLC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
234HRC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
Applicability: 50010-50018, 55003-55009, 55016, 55034, 55038-55039, 55041-55043
2.6 Remove the access panel that follows:
PANEL NAME REFERENCE
245ALC Ceiling panel AMP BD500-A-
J25-29-03-07AAA-520A-A
Applicability: 50010-50018, 55003-55016, 55020-55021, 55023, 55025, 55027, 55029-55030, 55032-55034,
55036, 55038-55046, 55110
2.7 Remove the access panel that follows:
PANEL NAME REFERENCE
246ARC Ceiling panel AMP BD500-A-
J25-29-03-06AAA-520A-A
Applicability: 50020-50061, 50063-50065, 55047-55048, 55050-55109, 55111-55172
2.8 Remove the access panels that follow:
PANEL NAME REFERENCE
223CCC Ceiling panel AMP BD500-A-
J25-29-03-08AAA-520A-A
233ACC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
233BCC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
233CCC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
233DCC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
233ECC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
233FCC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
243ACC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
Applicability: 55047-55048, 55050-55109, 55111-55172
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  13

### Page 14

BD500-252061
2.9 Remove the access panels that follow:
PANEL NAME REFERENCE
233GCC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
233HCC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-520A-A
Applicability: 55050-55055, 55064, 55067, 55071, 55076, 55078-55079, 55082-55083, 55086, 55088,
55090, 55092-55095, 55097-55100, 55102-55105, 55108-55109, 55111-55115, 55117-55124, 55126-55129,
55131-55134, 55137-55141, 55143-55144, 55146-55152, 55154-55169, 55171-55172
2.10 Remove the access panel that follows:
PANEL NAME REFERENCE
245ACC Ceiling panel AMP BD500-A-
J25-29-03-09AAA-520A-A
3 Procedure
Note
This procedure is applicable to the left and the right sides. The procedure that
follows is written for the left side. The differences are given.
3.1 If it is not possible to complete all the instructions in this service bulletin
because of the configuration of the aircraft, speak with a CRC representative
at 1 866 A220 CRC (1-866-222-0272) or 1-450-476-7676 or e-mail at
a220crc@airbus.com for analysis and to get an approved disposition to complete
this service bulletin.
3.2 Between FR22 and FR26, do an inspection of the tie rod (1) of the forward
left Overhead Storage Compartment (OHSC) to make sure that the clevis is
sufficiently engaged in the turnbuckle as follows:
Refer to Fig. 1.
3.2.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.2.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
3.2.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.2.2 If the clevis is engaged incorrectly, do the steps that follow:
3.2.2.1 Measure and record the length of the tie rod (1).
3.2.2.2 Disengage the clip from the tie rod (1).
3.2.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.2.2.4 Adjust both ends of the tie rod (1) so that:
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  14

### Page 15

BD500-252061
‐ The tie rod is the same length as the recorded value
in Step 3.2.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.2.2.5 Install the pin through the tie rod (1) and the fitting.
3.2.2.6 Turn the pin and the clip to the tie rod (1).
3.2.2.7 Engage the clip to the tie rod (1).
3.3 Between FR22 and FR26, do an inspection of the tie rod (1) of the forward
right OHSC to make sure that the clevis is sufficiently engaged in the turnbuckle
as follows:
Refer to Fig. 1.
3.3.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.3.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
3.3.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.3.2 If the clevis is engaged incorrectly, do the steps that follow:
3.3.2.1 Measure and record the length of the tie rod (1).
3.3.2.2 Disengage the clip from the tie rod (1).
3.3.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.3.2.4 Adjust both ends of the tie rod (1) so that:
‐ The tie rod is the same length as the recorded value
in Step 3.3.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.3.2.5 Install the pin through the tie rod (1) and the fitting.
3.3.2.6 Turn the pin and the clip to the tie rod (1).
3.3.2.7 Engage the clip to the tie rod (1).
Applicability: 50010-50018, 50020-50061, 50063-50065
3.4 Between FR26 and FR34, do an inspection of the tie rod (1) of the middle
OHSC to make sure that the clevis is sufficiently engaged in the turnbuckle as
follows:
Refer to Fig. 1.
3.4.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.4.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  15

### Page 16

BD500-252061
3.4.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.4.2 If the clevis is engaged incorrectly, do the steps that follow:
3.4.2.1 Measure and record the length of the tie rod (1).
3.4.2.2 Disengage the clip from the tie rod (1).
3.4.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.4.2.4 Adjust both ends of the tie rod (1) so that:
‐ The tie rod is the same length as the recorded value
in Step 3.4.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.4.2.5 Install the pin through the tie rod (1) and the fitting.
3.4.2.6 Turn the pin and the clip to the tie rod (1).
3.4.2.7 Engage the clip to the tie rod (1).
Applicability: 50010-50018, 50020-50061, 50063-50065
3.5 Between FR35 and FR39, do an inspection of the tie rod (1) of the middle
OHSC to make sure that the clevis is sufficiently engaged in the turnbuckle as
follows:
Refer to Fig. 1.
3.5.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.5.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
3.5.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.5.2 If the clevis is engaged incorrectly, do the steps that follow:
3.5.2.1 Measure and record the length of the tie rod (1).
3.5.2.2 Disengage the clip from the tie rod (1).
3.5.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.5.2.4 Adjust both ends of the tie rod (1) so that:
‐ The tie rod is the same length as the recorded value
in Step 3.5.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.5.2.5 Install the pin through the tie rod (1) and the fitting.
3.5.2.6 Turn the pin and the clip to the tie rod (1).
3.5.2.7 Engage the clip to the tie rod (1).
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  16

### Page 17

BD500-252061
Applicability: 50010-50018, 50020-50061, 50063-50065
3.6 Between FR40 and FR46, do an inspection of the tie rod (1) of the middle
OHSC to make sure that the clevis is sufficiently engaged in the turnbuckle as
follows:
Refer to Fig. 1.
3.6.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.6.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
3.6.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.6.2 If the clevis is engaged incorrectly, do the steps that follow:
3.6.2.1 Measure and record the length of the tie rod (1).
3.6.2.2 Disengage the clip from the tie rod (1).
3.6.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.6.2.4 Adjust both ends of the tie rod (1) so that:
‐ The tie rod is the same length as the recorded value
in Step 3.6.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.6.2.5 Install the pin through the tie rod (1) and the fitting.
3.6.2.6 Turn the pin and the clip to the tie rod (1).
3.6.2.7 Engage the clip to the tie rod (1).
Applicability: 50010-50018, 50020-50061, 50063-50065
3.7 Between FR47 and FR51, do an inspection of the tie rod (1) of the middle
OHSC to make sure that the clevis is sufficiently engaged in the turnbuckle as
follows:
Refer to Fig. 1.
3.7.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.7.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
3.7.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.7.2 If the clevis is engaged incorrectly, do the steps that follow:
3.7.2.1 Measure and record the length of the tie rod (1).
3.7.2.2 Disengage the clip from the tie rod (1).
3.7.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.7.2.4 Adjust both ends of the tie rod (1) so that:
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  17

### Page 18

BD500-252061
‐ The tie rod is the same length as the recorded value
in Step 3.7.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.7.2.5 Install the pin through the tie rod (1) and the fitting.
3.7.2.6 Turn the pin and the clip to the tie rod (1).
3.7.2.7 Engage the clip to the tie rod (1).
Applicability: 50010-50018, 50020-50061, 50063-50065
3.8 Between FR52 and FR56, do an inspection of the tie rod (1) of the middle
OHSC to make sure that the clevis is sufficiently engaged in the turnbuckle as
follows:
Refer to Fig. 1.
3.8.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.8.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
3.8.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.8.2 If the clevis is engaged incorrectly, do the steps that follow:
3.8.2.1 Measure and record the length of the tie rod (1).
3.8.2.2 Disengage the clip from the tie rod (1).
3.8.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.8.2.4 Adjust both ends of the tie rod (1) so that:
‐ The tie rod is the same length as the recorded value
in Step 3.8.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.8.2.5 Install the pin through the tie rod (1) and the fitting.
3.8.2.6 Turn the pin and the clip to the tie rod (1).
3.8.2.7 Engage the clip to the tie rod (1).
Applicability: 50010-50018, 50020-50061, 50063-50065
3.9 Between FR57 and FR65, do an inspection of the tie rod (1) of the middle
OHSC to make sure that the clevis is sufficiently engaged in the turnbuckle as
follows:
Refer to Fig. 1.
3.9.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.9.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  18

### Page 19

BD500-252061
3.9.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.9.2 If the clevis is engaged incorrectly, do the steps that follow:
3.9.2.1 Measure and record the length of the tie rod (1).
3.9.2.2 Disengage the clip from the tie rod (1).
3.9.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.9.2.4 Adjust both ends of the tie rod (1) so that:
‐ The tie rod is the same length as the recorded value
in Step 3.9.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.9.2.5 Install the pin through the tie rod (1) and the fitting.
3.9.2.6 Turn the pin and the clip to the tie rod (1).
3.9.2.7 Engage the clip to the tie rod (1).
Applicability: 50010-50018, 50020-50061, 50063-50065
3.10 Between FR67 and FR70, do an inspection of the tie rod (1) of the middle
OHSC to make sure that the clevis is sufficiently engaged in the turnbuckle as
follows:
Refer to Fig. 1.
3.10.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.10.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
3.10.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.10.2 If the clevis is engaged incorrectly, do the steps that follow:
3.10.2.1 Measure and record the length of the tie rod (1).
3.10.2.2 Disengage the clip from the tie rod (1).
3.10.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.10.2.4 Adjust both ends of the tie rod (1) so that:
‐ The tie rod is the same length as the recorded value
in Step 3.10.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.10.2.5 Install the pin through the tie rod (1) and the fitting.
3.10.2.6 Turn the pin and the clip to the tie rod (1).
3.10.2.7 Engage the clip to the tie rod (1).
Applicability: 55003-55016, 55018-55172
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  19

### Page 20

BD500-252061
3.11 Between FR26 and FR30A, do an inspection of the tie rod (1) of the middle
OHSC to make sure that the clevis is sufficiently engaged in the turnbuckle as
follows:
Refer to Fig. 1.
3.11.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.11.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
3.11.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.11.2 If the clevis is engaged incorrectly, do the steps that follow:
3.11.2.1 Measure and record the length of the tie rod (1).
3.11.2.2 Disengage the clip from the tie rod (1).
3.11.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.11.2.4 Adjust both ends of the tie rod (1) so that:
‐ The tie rod is the same length as the recorded value
in Step 3.11.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.11.2.5 Install the pin through the tie rod (1) and the fitting.
3.11.2.6 Turn the pin and the clip to the tie rod (1).
3.11.2.7 Engage the clip to the tie rod (1).
Applicability: 55003-55016, 55018-55172
3.12 Between FR31 and FR34, do an inspection of the tie rod (1) of the middle
OHSC to make sure that the clevis is sufficiently engaged in the turnbuckle as
follows:
Refer to Fig. 1.
3.12.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.12.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
3.12.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.12.2 If the clevis is engaged incorrectly, do the steps that follow:
3.12.2.1 Measure and record the length of the tie rod (1).
3.12.2.2 Disengage the clip from the tie rod (1).
3.12.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.12.2.4 Adjust both ends of the tie rod (1) so that:
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  20

### Page 21

BD500-252061
‐ The tie rod is the same length as the recorded value
in Step 3.12.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.12.2.5 Install the pin through the tie rod (1) and the fitting.
3.12.2.6 Turn the pin and the clip to the tie rod (1).
3.12.2.7 Engage the clip to the tie rod (1).
Applicability: 55003-55016, 55018-55172
3.13 Between FR35 and FR39, do an inspection of the tie rod (1) of the middle
OHSC to make sure that the clevis is sufficiently engaged in the turnbuckle as
follows:
Refer to Fig. 1.
3.13.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.13.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
3.13.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.13.2 If the clevis is engaged incorrectly, do the steps that follow:
3.13.2.1 Measure and record the length of the tie rod (1).
3.13.2.2 Disengage the clip from the tie rod (1).
3.13.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.13.2.4 Adjust both ends of the tie rod (1) so that:
‐ The tie rod is the same length as the recorded value
in Step 3.13.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.13.2.5 Install the pin through the tie rod (1) and the fitting.
3.13.2.6 Turn the pin and the clip to the tie rod (1).
3.13.2.7 Engage the clip to the tie rod (1).
Applicability: 55003-55016, 55018-55172
3.14 Between FR40 and FR46, do an inspection of the tie rod (1) of the middle
OHSC to make sure that the clevis is sufficiently engaged in the turnbuckle as
follows:
Refer to Fig. 1.
3.14.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.14.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  21

### Page 22

BD500-252061
3.14.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.14.2 If the clevis is engaged incorrectly, do the steps that follow:
3.14.2.1 Measure and record the length of the tie rod (1).
3.14.2.2 Disengage the clip from the tie rod (1).
3.14.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.14.2.4 Adjust both ends of the tie rod (1) so that:
‐ The tie rod is the same length as the recorded value
in Step 3.14.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.14.2.5 Install the pin through the tie rod (1) and the fitting.
3.14.2.6 Turn the pin and the clip to the tie rod (1).
3.14.2.7 Engage the clip to the tie rod (1).
Applicability: 55003-55016, 55018-55172
3.15 Between FR47 and FR51, do an inspection of the tie rod (1) of the middle
OHSC to make sure that the clevis is sufficiently engaged in the turnbuckle as
follows:
Refer to Fig. 1.
3.15.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.15.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
3.15.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.15.2 If the clevis is engaged incorrectly, do the steps that follow:
3.15.2.1 Measure and record the length of the tie rod (1).
3.15.2.2 Disengage the clip from the tie rod (1).
3.15.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.15.2.4 Adjust both ends of the tie rod (1) so that:
‐ The tie rod is the same length as the recorded value
in Step 3.15.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.15.2.5 Install the pin through the tie rod (1) and the fitting.
3.15.2.6 Turn the pin and the clip to the tie rod (1).
3.15.2.7 Engage the clip to the tie rod (1).
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  22

### Page 23

BD500-252061
Applicability: 55003-55016, 55018-55172
3.16 Between FR52 and FR56, do an inspection of the tie rod (1) of the middle
OHSC to make sure that the clevis is sufficiently engaged in the turnbuckle as
follows:
Refer to Fig. 1.
3.16.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.16.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
3.16.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.16.2 If the clevis is engaged incorrectly, do the steps that follow:
3.16.2.1 Measure and record the length of the tie rod (1).
3.16.2.2 Disengage the clip from the tie rod (1).
3.16.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.16.2.4 Adjust both ends of the tie rod (1) so that:
‐ The tie rod is the same length as the recorded value
in Step 3.16.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.16.2.5 Install the pin through the tie rod (1) and the fitting.
3.16.2.6 Turn the pin and the clip to the tie rod (1).
3.16.2.7 Engage the clip to the tie rod (1).
Applicability: 55003-55016, 55018-55172
3.17 Between FR57 and FR59, do an inspection of the tie rod (1) of the middle
OHSC to make sure that the clevis is sufficiently engaged in the turnbuckle as
follows:
Refer to Fig. 1.
3.17.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.17.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
3.17.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.17.2 If the clevis is engaged incorrectly, do the steps that follow:
3.17.2.1 Measure and record the length of the tie rod (1).
3.17.2.2 Disengage the clip from the tie rod (1).
3.17.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.17.2.4 Adjust both ends of the tie rod (1) so that:
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  23

### Page 24

BD500-252061
‐ The tie rod is the same length as the recorded value
in Step 3.17.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.17.2.5 Install the pin through the tie rod (1) and the fitting.
3.17.2.6 Turn the pin and the clip to the tie rod (1).
3.17.2.7 Engage the clip to the tie rod (1).
Applicability: 55003-55016, 55018-55172
3.18 Between FR60 and FR65, do an inspection of the tie rod (1) of the middle
OHSC to make sure that the clevis is sufficiently engaged in the turnbuckle as
follows:
Refer to Fig. 1.
3.18.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.18.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
3.18.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.18.2 If the clevis is engaged incorrectly, do the steps that follow:
3.18.2.1 Measure and record the length of the tie rod (1).
3.18.2.2 Disengage the clip from the tie rod (1).
3.18.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.18.2.4 Adjust both ends of the tie rod (1) so that:
‐ The tie rod is the same length as the recorded value
in Step 3.18.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.18.2.5 Install the pin through the tie rod (1) and the fitting.
3.18.2.6 Turn the pin and the clip to the tie rod (1).
3.18.2.7 Engage the clip to the tie rod (1).
Applicability: 55003-55016, 55018-55172
3.19 Between FR67 and FR70, do an inspection of the tie rod (1) of the middle
OHSC to make sure that the clevis is sufficiently engaged in the turnbuckle as
follows:
Refer to Fig. 1.
3.19.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.19.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  24

### Page 25

BD500-252061
3.19.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.19.2 If the clevis is engaged incorrectly, do the steps that follow:
3.19.2.1 Measure and record the length of the tie rod (1).
3.19.2.2 Disengage the clip from the tie rod (1).
3.19.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.19.2.4 Adjust both ends of the tie rod (1) so that:
‐ The tie rod is the same length as the recorded value
in Step 3.19.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.19.2.5 Install the pin through the tie rod (1) and the fitting.
3.19.2.6 Turn the pin and the clip to the tie rod (1).
3.19.2.7 Engage the clip to the tie rod (1).
Applicability: 50010-50018, 55003-55009, 55016, 55034, 55038-55039, 55041-55043, 55050-55055, 55064,
55067, 55071, 55076, 55078-55079, 55082-55083, 55086, 55088, 55090, 55092-55095, 55097-55100,
55102-55105, 55108-55109, 55111-55115, 55117-55124, 55126-55129, 55131-55134, 55137-55141,
55143-55144, 55146-55152, 55154-55167, 55169, 55171-55172
3.20 Between FR71 and FR74, do an inspection of the tie rod (1) of the aft left
OHSC to make sure that the clevis is sufficiently engaged in the turnbuckle as
follows:
Refer to Fig. 1.
3.20.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.20.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
3.20.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.20.2 If the clevis is engaged incorrectly, do the steps that follow:
3.20.2.1 Measure and record the length of the tie rod (1).
3.20.2.2 Disengage the clip from the tie rod (1).
3.20.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.20.2.4 Adjust both ends of the tie rod (1) so that:
‐ The tie rod is the same length as the recorded value
in Step 3.20.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.20.2.5 Install the pin through the tie rod (1) and the fitting.
3.20.2.6 Turn the pin and the clip to the tie rod (1).
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  25

### Page 26

BD500-252061
3.20.2.7 Engage the clip to the tie rod (1).
Applicability: 50010-50018, 55003-55016, 55020-55021, 55023, 55025, 55027, 55029-55030, 55032-55034,
55036, 55038-55046, 55050-55055, 55064, 55067, 55071, 55076, 55078-55079, 55082-55083, 55086,
55088, 55090, 55092-55095, 55097-55100, 55102-55105, 55108-55115, 55117-55124, 55126-55129,
55131-55134, 55137-55141, 55143-55144, 55146-55152, 55154-55169, 55171-55172
3.21 Between FR71 and FR74, do an inspection of the tie rod (1) of the aft right
OHSC to make sure that the clevis is sufficiently engaged in the turnbuckle as
follows:
Refer to Fig. 1.
3.21.1 Put a pin with a diameter that is less than 0.062 in. (1.57 mm) in the
inspection hole of the tie rod (1).
3.21.1.1 If the pin does not go through the tie rod, the clevis is
engaged correctly.
3.21.1.2 If the pin goes through the tie rod, the clevis is engaged
incorrectly.
3.21.2 If the clevis is engaged incorrectly, do the steps that follow:
3.21.2.1 Measure and record the length of the tie rod (1).
3.21.2.2 Disengage the clip from the tie rod (1).
3.21.2.3 Pull the pin and disconnect the tie rod (1) from the fitting.
3.21.2.4 Adjust both ends of the tie rod (1) so that:
‐ The tie rod is the same length as the recorded value
in Step 3.21.2.1.
‐ A pin with a diameter that is less than 0.062 in.
(1.57 mm) put in the inspection hole of the tie rod (1)
does not go through the tie rod.
3.21.2.5 Install the pin through the tie rod (1) and the fitting.
3.21.2.6 Turn the pin and the clip to the tie rod (1).
3.21.2.7 Engage the clip to the tie rod (1).
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  26

### Page 27

BD500-252061
NOTE
Aircraft 50010-50018
ICN-BD500-A-J252061-F-3AB48-81285-A-001-01
Fig. 1 OHSC Tie Rod - Inspection
- (Sheet 1 of 9)
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  27

### Page 28

BD500-252061
NOTE
Aircraft 50020-50061, 50063-50065
ICN-BD500-A-J252061-F-3AB48-81286-A-001-01
Fig. 1 OHSC Tie Rod - Inspection
- (Sheet 2 of 9)
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  28

### Page 29

BD500-252061
NOTE
Aircraft 55003-55009, 55016, 55034, 55038-55039,
55041-55043, 55050-55055, 55064, 55067, 55071,
55076, 55078-55079, 55082-55083, 55086, 55088,
55090, 55092-55095, 55097-55100, 55102-55105,
55108-55109, 55111-55115, 55117-55124, 55126-55129,
55131-55134, 55137-55141, 55143-55144, 55146-55152,
55154-55167, 55169, 55171-55172
ICN-BD500-A-J252061-F-3AB48-81287-A-001-01
Fig. 1 OHSC Tie Rod - Inspection
- (Sheet 3 of 9)
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  29

### Page 30

BD500-252061
NOTE
Aircraft 55018-55019, 55022, 55024, 55026, 55028,
55031, 55035, 55037, 55047-55049, 55056-55063,
55065-55066, 55068-55070, 55072-55075, 55077,
55080-55081, 55084-55085, 55087, 55089, 55091,
55096, 55101, 55106-55107, 55116, 55125, 55130,
55135-55136, 55142, 55145, 55153, 55170
ICN-BD500-A-J252061-F-3AB48-81288-A-001-01
Fig. 1 OHSC Tie Rod - Inspection
- (Sheet 4 of 9)
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  30

### Page 31

BD500-252061
NOTE
Aircraft 55010-55015, 55020-55021, 55023,
55025, 55027, 55029-55030, 55032-55033,
55036, 55040, 55044-55046, 55110, 55168
ICN-BD500-A-J252061-F-3AB48-81289-A-001-01
Fig. 1 OHSC Tie Rod - Inspection
- (Sheet 5 of 9)
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  31

### Page 32

BD500-252061
FORWARD LEFT OHSC
TYPICAL INSTALLATION FR22 TO FR26
FORWARD RIGHT OHSC
TYPICAL INSTALLATION FR22 TO FR26
ICN-BD500-A-J252061-F-3AB48-81290-A-001-01
Fig. 1 OHSC Tie Rod - Inspection
- (Sheet 6 of 9)
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  32

### Page 33

BD500-252061
MIDDLE OHSC
TYPICAL INSTALLATION FR26 TO FR70
AFT LEFT OHSC
TYPICAL INSTALLATION FR71 TO FR74
ICN-BD500-A-J252061-F-3AB48-81291-A-001-01
Fig. 1 OHSC Tie Rod - Inspection
- (Sheet 7 of 9)
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  33

### Page 34

BD500-252061
AFT RIGHT OHSC
TYPICAL INSTALLATION FR71 TO FR74
ICN-BD500-A-J252061-F-3AB48-81292-A-001-01
Fig. 1 OHSC Tie Rod - Inspection
- (Sheet 8 of 9)
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  34

### Page 35

BD500-252061
LEGEND
TIE ROD
TYPICAL INSTALLATION
1. Tie rod
1
CLIP
PIN
INSPECTION
HOLE
ICN-BD500-A-J252061-F-3AB48-81293-A-001-01
Fig. 1 OHSC Tie Rod - Inspection
- (Sheet 9 of 9)
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  35

### Page 36

BD500-252061
4 Job close-up
Note
The steps in the Job close-up section of this service bulletin, except for the
return-to-service tests, are recommended steps. The steps give a recommendation
to install components removed during the Job set-up. This recommendation is
to make sure that the aircraft is safe and ready to return to service. Alternative
steps can be used at the discretion of the operator.
4.1 Remove all tools, equipment, and unwanted materials from the work area.
Applicability: 50010-50018, 55010-55015, 55020-55021, 55023, 55025, 55027, 55029-55030, 55032-55033,
55036, 55040, 55044-55046, 55110
4.2 Install the access panels that follow:
PANEL NAME REFERENCE
223CLC Ceiling panel AMP BD500-A-
J25-29-03-05ACA-720A-A
224CRC Ceiling panel AMP BD500-A-
J25-29-03-04ACA-720A-A
Applicability: 55003-55009, 55016, 55018-55019, 55022, 55024, 55026, 55028, 55031, 55034-55035,
55037-55039, 55041-55043, 55049
4.3 Install the access panels that follow:
PANEL NAME REFERENCE
223CLC Ceiling panel AMP BD500-A-
J25-29-03-05AAA-720A-A
224CRC Ceiling panel AMP BD500-A-
J25-29-03-04AAA-720A-A
Applicability: 50010-50018, 55003-55016, 55018-55046, 55049, 55110
4.4 Install the access panels that follow:
PANEL NAME REFERENCE
233ALC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
234ARC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
233BLC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
234BRC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
233CLC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  36

### Page 37

BD500-252061
PANEL NAME REFERENCE
234CRC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
233DLC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
234DRC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
233ELC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
234ERC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
233FLC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
234FRC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
243ALC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
244ARC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
Applicability: 55003-55016, 55018-55046, 55049, 55110
4.5 Install the access panels that follow:
PANEL NAME REFERENCE
233GLC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
234GRC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
233HLC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
234HRC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
Applicability: 50010-50018, 55003-55009, 55016, 55034, 55038-55039, 55041-55043
4.6 Install the access panel that follows:
PANEL NAME REFERENCE
245ALC Ceiling panel AMP BD500-A-
J25-29-03-07AAA-720A-A
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  37

### Page 38

BD500-252061
Applicability: 50010-50018, 55003-55016, 55020-55021, 55023, 55025, 55027, 55029-55030, 55032-55034,
55036, 55038-55046, 55110
4.7 Install the access panel that follows:
PANEL NAME REFERENCE
246ARC Ceiling panel AMP BD500-A-
J25-29-03-06AAA-720A-A
Applicability: 50020-50061, 50063-50065, 55047-55048, 55050-55109, 55111-55172
4.8 Install the access panels that follow:
PANEL NAME REFERENCE
223CCC Ceiling panel AMP BD500-A-
J25-29-03-08AAA-720A-A
233ACC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
233BCC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
233CCC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
233DCC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
233ECC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
233FCC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
243ACC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
Applicability: 55047-55048, 55050-55109, 55111-55172
4.9 Install the access panels that follow:
PANEL NAME REFERENCE
233GCC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
233HCC Ceiling panel AMP BD500-A-
J25-29-03-01AAA-720A-A
Applicability: 55050-55055, 55064, 55067, 55071, 55076, 55078-55079, 55082-55083, 55086, 55088,
55090, 55092-55095, 55097-55100, 55102-55105, 55108-55109, 55111-55115, 55117-55124, 55126-55129,
55131-55134, 55137-55141, 55143-55144, 55146-55152, 55154-55169, 55171-55172
4.10 Install the access panel that follows:
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  38

### Page 39

BD500-252061
PANEL NAME REFERENCE
245ACC Ceiling panel AMP BD500-A-
J25-29-03-09AAA-720A-A
5 Administrative
When this service bulletin is completed, record in the applicable aircraft records that
you have completed this service bulletin.
Requirements after job completion
Required conditions
Table 6  Required conditions
Action/Condition Data Module/Technical publication
None
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
End of data module
 2025-02-20 Page  39

### Page 40

BD500-252061
Intentionally left blank
See applicability on the first page of the DM
BD500-A-J25-20-61-01AAA-933A-A (001)
BD500-A-J25-20-61-01AAA-933A-A (001)
 2025-02-20 Page  40

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.