### Page 1

Airbus Amber
CUSTOMER SERVICES DIRECTORATE
2 ROND POINT EMILE DEWOITINE
31700 BLAGNAC FRANCE
TELEPHONE + 33 (0)5 61 93 33 33
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 1 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
SUBJECT: ATA 32 – Main Landing Gear Door Actuator quality issue during manufacturing
AIRCRAFT TYPE: A318, A319, A320, A321
OUR REF.: A32N033-24 Rev 00 dated 29-OCT-2024
EFFECTIVITY DATE: 08 Nov 2024
1. AIRCRAFT AFFECTED
A/C type Serie
A318 A318-100
A319 A319-100
A319 A319-100N
A320 A320-200
A320 A320-200N
A321 A321-100
A321 A321-200
A321 A321-200N
A321 A321-200NX
Aircraft MSN (Manufacturer Serial Number) after 11545 are not affected by this AOT if and only if the MLG 
Door Actuators have never been replaced since aircraft delivery.
2. REFERENCED DOCUMENTATION
2.1 APPENDIX
Appendix 1: LIST OF SUSPECTED MLG DOOR ACTUATOR P/N 114122015 SERIAL NUMBERS.
Appendix 2: MLG Door Actuator inspection measurement figure.
Appendix 3: MLG Door Actuator Reporting sheet.
Appendix 4: Repair procedure - MLG Door Actuator replacement and hydraulic lines flushing.
2.2 REFERENCES
- Reference 1: CMM 32-31-35 COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS 
LIST MLG DOOR ACTUATOR
- Reference 2: SB A320-32-1407 LANDING GEAR - NORMAL EXTENSION AND RETRACTION – 
MODIFY THE MLG DOOR ACTUATOR DAMPING MECHANISM
- Reference 3: MOD 153655 LANDING GEAR - NORMAL EXTENSION AND RETRACTION - MODIFY 
THE MLG DOOR ACTUATOR DAMPING MECHANISM
- Reference 4: AMM task 32-31-35-000-001-A - Removal of the MLG Door Actuating-Cylinder.
- Reference 5: AMM task 32-31-35-400-001-A - Installation of the MLG Door Actuating-Cylinder.

### Page 2

Airbus Amber
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 2 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
- Reference 6: Airbus Retrofit Information Letter (RIL) Ref. SA32M24002217 rev 00 or any later revision 
if applicable (associated to ISI 32.31.00101).
- Reference 7: AMM TASK 32-12-00-010-001-A Open the Main Gear Doors for Access.
- Reference 8: AMM TASK 32-12-00-410-001-A Close the Main Gear Doors after Access.
3. REASON
The purpose of this AOT is to inform A320 Family operators of recent cases of Main Landing Gear (MLG) 
Door Actuator Part Number (P/N) 114122015 internal damage. It requests A320 Family operators to check 
the MLG Door Actuator Serial Numbers (S/N) fitted on their aircraft and perform a weekly on wing 
inspection of the suspected units listed in appendix 1 pending replacement of the suspected parts.
3.1 FACTS
3 aircraft fitted with MLG Door Actuator P/N 114122015 were reported having experienced issues with 
the opening of the MLG door during maintenance operations. Operators reported either the inability to 
install the door actuator maintenance lock sleeve due to a reduced rod extension or a jamming of the MLG 
Door during opening with Ground Door Opening system.
3.2 HISTORY/BACKGROUND
The MLG Door Actuator includes a damping device at the end of the stroke that provides progressive 
damping during extension. This damping device is composed of a damping ring (item 2-140 of CMM 32-
31-35) held in place by a threaded locking ring (item 2-135 of CMM 32-31-35). In addition to the thread, 
this locking ring is locked in place by a deforming (peening) process on the piston rod.

### Page 3

Airbus Amber
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 3 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
3.3 ROOT CAUSE
The shop inspection of the 3 failed MLG Door Actuators P/N 114122015 showed the threaded locking 
ring unscrewed and the piston damping ring and adjacent part damaged (see example of the damage on 
the following picture). 
As a result of the locking ring being unscrewed, the damping ring and the adjacent part became detached 
and damaged during actuator operation.
3.4 INVESTIGATION
Laboratory investigation of the 3 failed MLG Door Actuators P/N 114122015 showed that the threaded 
locking ring had not been deformed (not peened) as required by the assembly process (reference 1 - 
paragraph Assembly - 2. Procedure - C.8.h).
An in-depth quality investigation performed by AIRBUS and the Original Equipment Manufacturer 
(TRIUMPH) has determined that the piston assembly was not assembled correctly.
In the frame of the investigation, a batch of suspected MLG Door Actuator that may not have a deformed 
(not peened) locking ring has been defined in appendix 1.
In addition, a corrective action has been set up by TRIUMPH in order to reinforce their quality check 
process.
NOTE: This quality issue does not question the redesign of the MLG Door Actuator damping mechanism 
introduced by Ref. 2 and Ref. 3.
3.5 CONSEQUENCES
Damage to the internal parts may result in the slow extension of the actuator rod delaying the MLG Door 
operation or stopping just before the end of stroke, preventing the door from reaching the fully open 
position. Ultimately, it may prevent the extension of the Main Landing Gear by the normal system and the 
alternate system (free-fall).
4. OBJECTIVES OF THIS AOT
This AOT request A320 Family operators to check the MLG Door Actuator S/N fitted on their aircraft and 
perform a repetitive on-wing inspection (refer to paragraph 5.6.2) for MLG Door Actuators listed in 
appendix 1. This inspection must be performed weekly until the replacement of suspected door actuators 
(refer to paragraph 5.6.3).

### Page 4

Airbus Amber
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 4 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
5. MAINTENANCE PROCEDURE
NOTE: This AOT is classified mandatory or expected to be classified mandatory by an 
Airworthiness Directive (AD). If the instructions of this AOT are marked as Required for Compliance 
(RC), the operator must follow the instructions as indicated. These instructions are introduced by 
“in accordance with”.
NOTE: The instructions of this AOT include procedures given in other documents or in other 
sections of the AOT. If the instructions of this AOT are NOT marked as Required for Compliance 
(RC), the operator can use an alternative procedure accepted by his/her local authority. These 
instructions are introduced by “refer to”.
NOTE: When this AOT gives the access or close-up instructions with no return to service tests, the 
operator can adapt these instructions to add flexibility to the maintenance operations. The technical 
intent of this AOT must comply with the set parameters.
5.1 PLANNING - (RC)
- Within 2 weeks from the effective date of this AOT, perform a check of the MLG Door Actuators 
S/N fitted on all affected aircraft as per paragraph 5.6.1.
- Within 2 weeks from the effective date of this AOT, perform a repetitive inspection at intervals 
not to exceed 8 calendar days or 5 FC, whichever occurs later, as per paragraph 5.6.2 on 
aircraft fitted with a suspected MLG Door Actuator S/N listed in appendix 1.
- Within 12 months from the effective date of this AOT, replace the suspected MLG Door 
Actuators as per paragraph 5.6.3 with non-suspected MLG Door Actuators.
5.2 MANPOWER
- The estimated time to perform the check of the MLG Door Actuators S/N as per paragraph. 
5.6.1 is 0.5 Man hours.
- The estimated time to perform the weekly on wing inspection of a suspected MLG Door Actuator 
as per paragraph 5.6.2 is 1.5 Man hours.
- The estimated time to perform the replacement of a suspected MLG Door Actuator as per 
terminating action paragraph 5.6.3 is 3 Man hours.
- The estimated time to perform the replacement of a suspected MLG Door Actuator as per 
paragraph 5.6.4 in case of findings during the weekly inspection is 7 Man hours.
5.3 ACCESS
-AMM task 32-12-00-010-001-A - Open the Main Gear Doors for Access.
-AMM task 32-12-00-410-001-A - Close the Main Gear Doors after Access.
5.4 INSPECTION – (RC)
Perform the inspections detailed in paragraph 5.6 INSTRUCTIONS.
5.5 FINDINGS
Refer to the instruction in paragraph 5.6 INSTRUCTIONS.

### Page 5

Airbus Amber
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 5 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
5.6 INSTRUCTIONS 
5.6.1 MLG Door Actuator S/N check - (RC)
1/ Within 2 weeks from the effective date of this AOT, perform a check of the MLG 
Door Actuator P/N and S/N fitted. This can be done by either:
A) Check the Landing Gear records of the affected aircraft to determine 
the LH and the RH MLG Door Actuator Part Number (P/N) and Serial 
Number (S/N) fitted.
Or.
B) As an alternative to the landing gear records check, the P/N and the 
S/N can be checked physically on the nameplate (CMM 32-31-35 item 2-
240) localized on the cylinder middle area (see following picture).
a) Open the MLG Door refer to AMM TASK 32-12-00-010-001-A Open 
the Main Gear Doors for Access.
b) Check the LH and the RH MLG Door Actuator Part Number (P/N) 
and Serial Number (S/N).
c) Close the MLG Door refer to AMM TASK 32-12-00-410-001-A Close 
the Main Gear Doors after Access.
2/ Check if the MLG Door Actuators S/N of the affected aircraft are in the list of 
appendix 1.
-If the LH and the RH MLG Door Actuators S/N of the affected aircraft are 
not listed in the appendix 1 then No further action is necessary by this AOT.
-If one or both of the MLG Door Actuators S/N of the affected aircraft are 
listed in the appendix 1 then go to the step 3.
3/ Check physically if the amendment plate (CMM 32-31-35 item 2-220) of the MLG 
Door Actuator listed in the appendix 1 has the reference “PINSP” scribed (see 
pictures below).

### Page 6

Airbus Amber
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 6 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
-If the LH and the RH MLG Door Actuators S/N fitted on affected aircraft are 
listed in the appendix 1 and the amendment plates are scribed with the 
reference “PINSP” then no further action is necessary by this AOT.
-If one or both MLG Door Actuators S/N fitted on the effected aircraft are listed 
in the appendix 1 and the reference “PINSP” are not scribed on the amendment 
plates report to AIRBUS (refer to paragraph 8. REPORTING) and go to step 4.
Note: Any actuator listed in Appendix 1 with the ref “PINSP” scribed on the 
Amendment plate, is no longer considered suspected. No actions are required for 
actuators listed in appendix 1 with reference “PINSP” scribed on the amendment 
plate.  
4/  Within 2 weeks from the effective date of this AOT, perform a repetitive inspection 
at intervals not to exceed 8 calendar days or 5 FC, whichever occurs later, as per 
paragraph 5.6.2 on the suspected MLG door actuators.
NOTE: Any MLG Door Actuator P/N114122015 is considered suspected if its S/N is 
listed in appendix 1 and there is no reference “PINSP” scribed on the amendment plate.
5/ Replace the suspected MLG Door Actuator as per paragraph 5.6.3 within 12  months 
from the effective date of this AOT.
5.6.2 MLG Door Actuator on wing inspection
Accomplish the following repetitive inspection at intervals not to exceed 8 calendar days or 5 
FC, whichever occurs later, until all suspected MLG Door Actuators fitted on the aircraft have 
been replaced as per paragraph 5.6.3 or 5.6.4.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A 
TASK ON OR NEAR:
-THE FLIGHT CONTROLS
-THE FLIGHT CONTROL SURFACES
-THE LANDING GEAR AND THE RELATED DOORS
-COMPONENTS THAT MOVE.

### Page 7

Airbus Amber
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 7 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN 
CAUSE DAMAGE TO THE EQUIPMENT.
CAUTION:
ALWAYS OBEY THE PRECAUTIONS THAT FOLLOW TO KEEP ELECTRICAL WIRING IN A 
SATISFACTORY CONDITION (ELECTRICALLY AND MECHANICALLY SERVICEABLE). WHEN 
YOU DO MAINTENANCE WORK, REPAIRS OR MODIFICATIONS, ALWAYS KEEP ELECTRICAL 
WIRING, COMPONENTS AND THE WORK AREA AS CLEAN AS POSSIBLE. TO DO THIS: 
- PUT PROTECTION, SUCH AS PLASTIC SHEETING, CLOTHS, ETC; AS NECESSARY ON WIRING 
AND COMPONENTS.
- REGULARLY REMOVE ALL SHAVINGS, UNWANTED MATERIAL AND OTHER 
CONTAMINATION. 
THESE PRECAUTIONS WILL DECREASE THE RISK OF CONTAMINATION AND DAMAGE TO THE 
ELECTRICAL WIRING INSTALLATION. 
IF THERE IS CONTAMINATION, REFER TO ESPM 20-55-00.
5.6.2.1 Job Set-up
 A. Safety Precautions
(1) Make sure that the aircraft is electrically grounded Ref. AMM TASK 12-
34-24-869-002.
(2) As necessary, use the applicable SAFETY BARRIER(S), specified by the 
operator's instructions and your local regulations.
(3) On panel 400VU:
-Make sure that the landing-gear control lever is in the DOWN 
position
-Put WARNING NOTICE(S) in position to tell persons not to operate 
the landing gear.
(4) Put WARNING NOTICE(S) adjacent to the landing gear doors to tell 
persons not to go near the landing gear doors.
B. Aircraft Maintenance Configuration
(1) Make sure that the aircraft electrical circuits are de-energized Ref. AMM 
TASK 24-41-00-862-002.
(2) Make sure the MLG doors are closed Ref. AMM TASK 32-12-00-410-001.
5.6.2.2. Procedure  - (RC)
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE LANDING GEAR DOORS ARE CLEAR.
ACTION RESULT

### Page 8

Airbus Amber
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 8 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
1.Move the applicable ground door-
operating handle to the OPEN position 
Ref. AMM TASK 32-12-00-010-001. Wait 
for 30 seconds.
-The related MLG door moves to the fully 
open position
-The applicable MLG door actuating-
cylinder is vertical.
2.Make sure that the movement of the 
MLG door actuating-cylinder is smooth 
and continuous.
-The movement of the MLG Door 
Actuating cylinder is smooth and 
continuous.
3.Move the MLG door with your hand 
through approximately 30 degrees and 
back to the fully open position.
-The movement of the MLG door 
actuating-cylinder must be smooth and 
continuous. There must be hydraulic 
resistance only.
4.Measure the dimension (DIM A) with 
the MLG door fully opened (appendix 2).
-The dimension (DIM A) must not be less 
than 385 mm (15.16 in.).
6. If the MLG Door Actuator fails any of the above 4 inspections checks, it must be 
replaced before next flight in accordance with repair procedure of paragraph 5.6.4.
7. If nil findings go to paragraph 5.6.2.3. Close up.
5.6.2.3. Close-up
A. Close Access
 (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the MLG doors Ref. AMM TASK 32-12-00-410-001.
B. Removal of Equipment
 (1) Remove the WARNING NOTICE(S).
(2) Remove the SAFETY BARRIER(S).
(3) Remove the ground support and maintenance equipment, the special and 
standard tools and all other items.
5.6.3 Terminating action 
5.6.3.1  Replacement of the suspected MLG door actuators – (RC)
The suspected MLG Door Actuators must be replaced within 12 months from the effective date 
of this AOT by MLG Door Actuators not listed in appendix 1 or listed in appendix 1 with the 
reference “PINSP” scribed on the amendment plate (item 2-220 of CMM 32-31-35).
Do the replacement of the suspected MLG Door Actuators. Refer to reference 4 and 
reference 5.
NOTE: Any MLG Door Actuator is considered suspected if its S/N is listed in appendix 
1 and there is no reference “PINSP” scribed on the amendment plate.

### Page 9

Airbus Amber
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 9 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
After the replacement of all suspected MLG Door actuators fitted on the aircraft, no 
further action is required from this AOT.
5.6.3.2  Report the applicable data 
Record the applicable data of the removed parts on the reporting sheet (appendix 3) 
and send a copy to AIRBUS (see paragraph 8. REPORTING for details).
5.6.3.3  Return of the removed suspected MLG Door Actuators – (RC)
Return the removed suspected MLG Door Actuators with a copy of the reporting sheet 
(appendix 3) to:
AAR Component Repair – Amsterdam
Kruisweg 705,
2132 ND Hoofddorp,
Netherlands
CustomerSupport_ams@aarcorp.com
Refer to Airbus Retrofit Letter SA32M24002217 for further details.
5.6.4 Repair procedure – (RC)
If the suspected MLG door actuator fails the on-wing inspection check detailed in paragraph 5.6.2.2, do 
the repair procedure in accordance with appendix 4 prior to next flight.
Appendix 4 provides the required procedure to flush the potential contamination from the hydraulic 
landing gear extension and retraction lines in addition to the replacement of the MLG Door Actuator.
NOTE: Flushing is required as debris resulting from the internal damping mechanism components 
damage may contaminate the MLG Door Actuator hydraulic lines.
5.7 SPARES AND TOOLING
Airbus launches a monitored retrofit campaign to support the replacement of suspected Main Landing 
Gear Door Actuator S/N of appendix 1. Please refer to the RIL (Retrofit Information Letter) 
SA32M24002217 for further details on the industry support conditions and retrofit organization.
6. ADDITIONAL INFORMATION
6.1 FOLLOW-UP PLAN
It is anticipated that an Airworthiness Directive will be issued by EASA to mandate the content of this 
AOT.
6.2 IMPACTED DOCUMENTATION
This AOT has no impact on the published documentation.
7. AOT APPROVAL
The technical content of this document is approved under the authority of the DOA ref.EASA.21J.031.
8. REPORTING

### Page 10

Airbus Amber
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 10 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
Address one copy of your reporting sheet to Airbus Customer Services through the generic e-mail 
address. Refer to the latest reporting policy (Ref in the OIT 999.0018/16). Give the AOT reference in 
the mail title, as follows: A32N033-24 Inspection Result
For retrofit purpose, please provide your reporting sheet to Airbus Retrofit Services through the e-mail 
address monitored.retrofit@airbus.com
For any technical query, you can address your questions about this AOT to Airbus Customer 
Services through TechRequest on Airbus World, selecting Engineering Domain and ATA 32-
31/Topic AOT A32N033-24.
For any question related to retrofit aspect, you can address your questions about this AOT to 
monitored.retrofit@airbus.com
For any question related to spare and commercial aspect, you can address your questions 
about this AOT to:
Mark Cook | Programme Manager
Actuation Products and Services
49 Parkway, Zone 2, Deeside Industrial Park East, Deeside, CH5 2NS, UK
Mobile: 0044 75123 19461 | mcook@triumphgroup.com
Best Regards,
Ahmed CHABBOUH
Senior Director In-Service 
Engineering
Customer Care Center
Jean Pierre GOMEZ
Vice President A320 Programme 
Customer Services

### Page 11

Airbus Amber
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 11 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
APPENDIX 1 – LIST OF SUSPECTED MLG DOOR ACTUATOR P/N 
114122015 SERIAL NUMBERS
S/N S/N S/N S/N S/N S/N S/N
TA1800947 TA2007746 TA2008445 TA2008604 TA2010060 TA2010915 TA2012030
TA1904781 TA2007747 TA2008446 TA2008605 TA2010061 TA2010916 TA2012031
TA1904786 TA2007748 TA2008447 TA2008606 TA2010402 TA2010917 TA2012032
TA1909576 TA2007749 TA2008448 TA2008821 TA2010404 TA2010918 TA2012033
TA1910476 TA2007750 TA2008449 TA2009605 TA2010409 TA2011192 TA2012034
TA1910478 TA2007751 TA2008450 TA2009609 TA2010410 TA2011193 TA2012035
TA1910479 TA2007752 TA2008451 TA2009613 TA2010411 TA2011194 TA2012036
TA1911188 TA2007756 TA2008452 TA2009614 TA2010412 TA2011195 TA2012037
TA2007016 TA2007757 TA2008453 TA2009615 TA2010413 TA2011196 TA2012038
TA2007017 TA2007758 TA2008454 TA2009616 TA2010414 TA2011197 TA2012039
TA2007018 TA2007759 TA2008455 TA2009621 TA2010415 TA2011198 TA2012040
TA2007019 TA2007835 TA2008456 TA2009622 TA2010416 TA2011199 TA2012041
TA2007020 TA2007836 TA2008457 TA2009623 TA2010417 TA2011200 TA2012042
TA2007021 TA2007837 TA2008458 TA2009624 TA2010418 TA2011201 TA2012320
TA2007022 TA2007838 TA2008459 TA2009625 TA2010419 TA2011202 TA2012321
TA2007023 TA2007839 TA2008460 TA2009626 TA2010420 TA2011203 TA2012322
TA2007024 TA2007840 TA2008461 TA2009627 TA2010829 TA2011648 TA2012323
TA2007028 TA2007841 TA2008462 TA2009628 TA2010830 TA2011649 TA2012324
TA2007029 TA2007842 TA2008463 TA2010026 TA2010831 TA2011650 TA2012325
TA2007030 TA2007843 TA2008464 TA2010027 TA2010832 TA2011651 TA2012326
TA2007031 TA2007844 TA2008465 TA2010028 TA2010834 TA2011656 TA2012327
TA2007032 TA2007845 TA2008587 TA2010029 TA2010835 TA2011657 TA2012593
TA2007033 TA2007846 TA2008591 TA2010030 TA2010836 TA2011658 TA2012594
TA2007034 TA2007847 TA2008592 TA2010031 TA2010837 TA2011659 TA2012595
TA2007035 TA2007848 TA2008593 TA2010032 TA2010838 TA2012019 TA2012596
TA2007736 TA2007849 TA2008594 TA2010033 TA2010839 TA2012020 TA2113745
TA2007737 TA2007850 TA2008595 TA2010035 TA2010840 TA2012021
TA2007738 TA2007851 TA2008596 TA2010036 TA2010841 TA2012022
TA2007739 TA2007852 TA2008597 TA2010037 TA2010842 TA2012023
TA2007740 TA2007853 TA2008598 TA2010050 TA2010843 TA2012024
TA2007741 TA2007854 TA2008599 TA2010051 TA2010844 TA2012025
TA2007742 TA2007855 TA2008600 TA2010052 TA2010911 TA2012026
TA2007743 TA2008442 TA2008601 TA2010053 TA2010912 TA2012027
TA2007744 TA2008443 TA2008602 TA2010058 TA2010913 TA2012028
TA2007745 TA2008444 TA2008603 TA2010059 TA2010914 TA2012029

### Page 12

Airbus Amber
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 12 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
APPENDIX 2 - MLG Door Actuator inspection measurement

### Page 13 (OCR)

Airbus Amber
AIRBUS
ALERT OPERATORS TRANSMISSION - AOT
APPENDIX 3 - MLG Door Actuator reporting sheet
OPERATOR  A/C TYPE  MSN  REGISTRATION
DATE OF INSPECTION  PLACE OF INSPECTION
ACTUATING CYLINDER INFORMATION
PIN  S/N  POSITION ON
AIRCRAFT
DIMENSION 'A'
MEASUREMENT
FLIGHT CYCLES
INSTALLATION  DATE OF  INSTALLATION  SINCE  FLIGHT CYCLES  SINCE NEW
SELECT THE CORRECT ANSWER
ACTUATOR MOVEMENT  SMOOTH  INTERMITTENT  SUDDEN
MORE INFORMATION
AOT ref: A32N033-24 Rev 00  Page 13 of 22  Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0  © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT

### Page 14

Airbus Amber
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 14 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
APPENDIX 4 - Repair procedure - MLG Door Actuator 
replacement and hydraulic lines flushing.
Job Set-up Information
Fixtures, Tools, Test and Support Equipment
REFERENCE QTY DESIGNATION
No specific AR SAFETY BARRIER(S)
No specific AR WARNING NOTICE(S)
No specific AR MLG door actuator safety collars
No specific AR NLG door safety pin
No specific 1 Ground Hydraulic Cart (capable of delivering a 
flow rate of at least 80 litres/minute at 203 
bar).
98D32603000000 4 Flight Ground Simulation Plate
98F32304000000 6 MLG False Target
Components
REFERENCE QTY DESIGNATION
MS21902J6 4 UNION
AE2460010G0360 2 HOSE
MS21914J6 4 CAP
MS24665-153 1 PIN
Work Zones and Access Panels
ZONE/ACCESS ZONE DESCRIPTION
734 MAIN DOOR
744 MAIN DOOR
(1) PREPARATION
WARNING: MAKE SURE THAT YOU OBEY ALL THE WARNINGS AND ALL THE CAUTIONS 
INCLUDED IN THE REFERENCED PROCEDURES.
WARNING: MAKE SURE THERE ARE NO PERSONNEL NEAR THE FREE-FALL MECHANISM 
CABLES BEFORE YOU TURN THE GRAVITY GEAR EXTN HANDLE. INJURY CAN OCCUR IF 
PERSONNEL OR LOOSE CLOTHING BECOME CAUGHT IN THE FREE-FALL MECHANISM. 
WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU 
START A TASK ON OR NEAR:

### Page 15

Airbus Amber
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 15 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
- THE FLIGHT CONTROLS 
- THE FLIGHT CONTROL SURFACES 
- THE LANDING GEAR AND THE RELATED DOORS 
- COMPONENTS THAT MOVE. 
WARNING: OBEY THE HYDRAULIC SAFETY PROCEDURES. 
WARNING: DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO: 
- FLUSH IT AWAY WITH CLEAN WATER 
- GET MEDICAL AID. 
WARNING: OBEY THE WARNINGS AND CAUTIONS IN THE REFERENCED AMM TASKS.
WARNING: MAKE SURE THAT THE CONTROLS AGREE WITH THE POSITION OF THE ITEMS THEY 
OPERATE BEFORE YOU PRESSURIZE A HYDRAULIC SYSTEM. UNWANTED MOVEMENT OF 
HYDRAULICALLY OPERATED ITEMS CAN CAUSE SERIOUS INJURY AND/OR DAMAGE.
CAUTION: ALWAYS OBEY THE PRECAUTIONS THAT FOLLOW TO KEEP ELECTRICAL WIRING IN 
A SATISFACTORY CONDITION (ELECTRICALLY AND MECHANICALLY SERVICEABLE). WHEN 
YOU DO MAINTENANCE WORK, REPAIRS OR MODIFICATIONS, ALWAYS KEEP ELECTRICAL 
WIRING, COMPONENTS AND THE WORK AREA AS CLEAN AS POSSIBLE. TO DO THIS: 
- PUT PROTECTION, SUCH AS PLASTIC SHEETING, CLOTHS, ETC; AS NECESSARY ON WIRING 
AND COMPONENTS. 
- REGULARLY REMOVE ALL SHAVINGS, UNWANTED MATERIAL AND OTHER CONTAMINATION. 
THESE PRECAUTIONS WILL DECREASE THE RISK OF CONTAMINATION AND DAMAGE TO THE 
ELECTRICAL WIRING INSTALLATION. 
IF THERE IS CONTAMINATION, REFER TO ESPM 20-55-00.
(1) Job Set-up
(a) Make sure that the aircraft is electrically grounded, refer to AMM Task 12-34-24-
869-002.
(b) Make sure that the safety barriers are in position.
(c) In the cockpit on the panel 400VU: 
- Make sure that the L/G control-lever 6GA is in the DOWN position 
- Put a WARNING NOTICE(S) in position to tell persons not to operate the landing 
gear.
(d) Put the WARNING NOTICE(S) adjacent to the landing gear doors to tell persons 
not to go near the landing gear doors.
(e) Do the Job Set-up procedures as specified in the Removal of the MLG Door
Actuating Cylinder, refer to AMM Task 32-31-35-000-001.
(2) PROCEDURE
(1) Start to Flush the Contamination from the Landing Gear Extension and Retraction System
(a) Energize the aircraft electrical circuits using external ground power, refer to AMM 
Task 24-41-00-861-002.
(b) Depressurize the Green and Yellow Hydraulic Systems, refer to AMM Task 29-10-
00-864-001 and AMM Task 29-10-00-864-002.

### Page 16

Airbus Amber
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 16 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
(c) Open the Nose Landing Gear (NLG) doors for access, refer to AMM Task 32-22-
00-010-001.
(d) Open the LH and RH Main Landing Gear (MLG) doors for access, refer to AMM 
Task 32-12-00-010-001.
(e) Install the safety devices to all the landing gear doors, refer to AMM Task 32-00-00-
481-002.
(f) Install the safety devices on all the landing gear, refer to AMM Task 32-00-00-481-
001.
(g) Disconnect the PTU isolation coupling, refer to AMM Task 29-23-00-860-001.
(h) Depressurize the Green Hydraulic System reservoir, refer to AMM Task 29-14-00-
614-001.
(i) Do the flight configuration precautions, refer to AMM Task 32-00-00-860-001.
(j) On the weight on wheels proximity sensors 20GA, 21GA, 22GA, 23GA, 24GA and 
25GA install False Target MLG 98F32304000000 (illustration 1).
NOTE: This simulates S/A extended and removes the baulk on the L/G control lever.
(k) On the MLG Door Open proximity sensors 32GA, 33GA, 34GA and 35GA Install: 
98D32603000000 Simulation Plate Flight Ground (illustration 2).
NOTE: This simulates ’MLG Doors not open’, and prevents the L/G Extend and Retract 
commands from being generated.
(l) Check that the LH and RH doors show amber "in transit" on the ECAM WHEEL 
page.
(m) Disconnect the LH MLG door actuator from the swivel joint assembly 2763GM, 
refer to AMM Task 32-31-35-000-001.
(n) Disconnect the RH MLG door actuator from the swivel joint assembly 2764GM, refer 
to AMM Task 32-31-35-000-001.
(o) Install Cap (item 3) MS21914J6 to the RH and the LH MLG Door Actuator 
connections (illustration 3).
(p) Connect together, the door open and door close connections of the swivel joint 
2763GM with 1 Hose (item 2) AE2460010G0360 and 2 Unions (item 1) MS21902J6 
(illustration 3).
(q) Connect together, the door open and door close connections of the swivel joint 
2764GM with 1 Hose (item 2) AE2460010G0360 and 2 Unions (item 1) MS21902J6 
(illustration 3).
(r) Pressurize the Green Hydraulic System reservoir, refer to AMM Task 29-14-00-614-
002.
(s) Connect the ground hydraulic power-cart to the Green Hydraulic System, refer to 
AMM Task 29-10-00-863-001.
(t) Flush the LH and RH MLG Door Open and Close Lines as follows.
        1) In the cockpit, ensure the L/G control lever is in the DOWN position.
2) Set the ground hydraulic power-cart to low flow and pressurize the Green 
Hydraulic System to 150 BAR (2175 PSI), refer to AMM Task 29-10-00-863-
001.

### Page 17

Airbus Amber
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 17 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
3) Move the LH MLG door ground door opening handle to the CLOSED 
position, refer to AMM Task 32-12-00-410-001. 
NOTE: The LH and RH doors stay open.
        4) In the cockpit, move the L/G control lever to the UP position.
5) Pressurize the Green Hydraulic System using the Ground Hydraulic 
PowerCart, refer to AMM Task 29-10-00-863-001
-Flushing of the LH MLG door actuator hydraulic lines will now start
-Adjust the ground hydraulic power-cart to achieve a supply pressure 
of 160 BAR (2321 PSI)
-Continue flushing for 3 minutes
-Stop the flow from the ground hydraulic power-cart.
6) Move the LH MLG door opening handle to the OPEN position, refer to AMM 
Task 32-12-00-010-001.
        7) In the cockpit, move the L/G control lever to the DOWN position.
8) Set the ground hydraulic power-cart to low flow, and pressurize the Green 
Hydraulic System to 150 BAR (2175 PSI), refer to AMM Task 29-10-00-863-
001.
9) Move the RH MLG door ground door opening handle to the CLOSED 
position, refer to AMM Task 32-12-00-410-001. 
NOTE: The LH and RH doors stay open
        10) In the cockpit, move the L/G control lever to the UP position.
11) Pressurize the Green Hydraulic System using the Ground Hydraulic 
PowerCart, refer to AMM Task 29-10-00-863-001
-flushing of the RH MLG door actuator hydraulic lines will now start
-adjust the ground hydraulic power-cart to achieve a supply pressure 
of 160 BAR (2321 PSI)
-continue flushing for 3 minutes
-stop the flow from the ground hydraulic power-cart.
(u) Remove the Flushing Hose and Reconnect the MLG Door Actuator Hydraulic Lines 
as follows.
1) Depressurize the Green Hydraulic System, refer to AMM Task 29-10-00-
864-001. 
NOTE: It takes approximately 15 minutes for the hydraulic pressure in the 
system to fully depressurize.
2) Depressurize the Green Hydraulic System reservoir, refer to AMM Task 29-
14-00-614-001.

### Page 18

Airbus Amber
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 18 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
3) Remove the Hose (item 2) AE2460010G0360 and the 2 unions (item 1) 
MS21902J6 from the LH MLG Door Actuator Swivel Joint 2763GM (illustration 
3).
4) Remove the Hose (item 2) AE2460010G0360 and the 2 unions (item 1) 
MS21902J6 from the LH MLG Door Actuator Swivel Joint 2764GM (illustration 
3).
5) Remove the Caps (item 3) from the LH and the RH Actuator connections.
(2) Replacement of the suspected MLG Door Actuator
(a) Remove and replace the suspected MLG Door Actuator. Refer to AMM task 32-31-
35-000-001-A - Removal of the MLG Door Actuating-Cylinder and AMM task 32-31-35-
400-001-A - Installation of the MLG Door Actuating-Cylinder.
NOTE: Any MLG Door Actuator P/N114122015 is considered suspected if its S/N is 
listed in appendix 1 and there is no reference “PINSP” scribed on the amendment plate.
NOTE: The suspected MLG Door Actuator must be replaced by a MLG Door Actuator 
not listed in appendix 1 of AOT A32N033-24 or listed in appendix 1 of AOT A32N033-
24 with the reference “PINSP” scribed on the amendment plate.
NOTE: The replacement actuator must be mechanically and hydraulically connected. 
However, do not do the test at this time.
(b) Record the applicable data of the removed part on the reporting sheet appendix 3 
and send one copy to AIRBUS (see paragraph REPORTING) and send one copy to 
MRO AAR with the removed part (see paragraph SPARES AND TOOLING for more 
details).
(c) Return the removed suspected MLG Door Actuator to MRO AAR (see paragraph 
SPARES AND TOOLING for more details).
(3) Complete the Flushing Procedure
(a) Install the safety devices on the newly installed MLG door actuator(s), refer to AMM Task 
32-00-00-481-002. 
(b) Pressurize the Green Hydraulic System reservoir, refer to AMM Task 29-14-00-614-002. 
(c) Flush the LH and RH MLG Door Free Fall Extension Lines:
1) Disconnect the MLG vent valve input lever from the pushrod (illustration 4), Remove 
the Pin-Cotter MS24665-153 (item 8), the Nut (item 7), the Bolt (item 4), the Washer 
(item 6) and the Bush (item 5).
2) Manually operate the MLG vent valve to the OPEN position (move the lever in the 
clockwise direction until it reaches its internal stop).
3) Make sure that the safety devices are installed on the MLG door actuators, refer to 
AMM Task 32-00-00-481-002. 
4) Make sure that the Simulation Plates are still fitted to the MLG door open proximity 
sensors 32GA, 33GA, 34GA and 35GA (illustration 2). 
5) In the cockpit, move the L/G control lever to the UP position.

### Page 19

Airbus Amber
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 19 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
6) Make sure that the RH MLG door opening handle is in the CLOSED position and 
that the LH MLG door opening handle is in the OPEN position. 
7) Pressurize the Green Hydraulic System using the Ground Hydraulic Power Cart, 
refer to AMM Task 29-10-00-863-001: 
-Flushing of the LH MLG door actuator free fall hydraulic lines will now start 
-Adjust the ground hydraulic cart to achieve a supply pressure of 160 BAR 
(2321 PSI) 
-Continue flushing for 3 minutes 
-Stop the flow from the ground hydraulic-cart. 
8) Move the RH MLG door opening handle to the OPEN position, refer to AMM Task 
32-12-00-010-001. 
9) In the cockpit, move the L/G control lever to the DOWN position. 
10) Set the ground hydraulic power-cart to low flow and pressurize the Green Hydraulic 
System to 150 BAR (2175 PSI), refer to AMM Task 29-10-00-863-001.
11) Move the LH MLG door ground opening handle to the CLOSED position, refer to 
AMM Task 32-12-00-410-001. 
NOTE: The LH and RH MLG doors stay open. 
12) In the cockpit, move the L/G control lever to the UP position. 
13) Pressurize the Green Hydraulic System using the Ground Hydraulic PowerCart, 
refer to AMM Task 29-10-00-863-001: 
-Flushing of the RH MLG door actuator free fall hydraulic lines will now start 
-Adjust the ground hydraulic cart to achieve a supply pressure of 160 BAR 
(2321 PSI) 
-Continue flushing for 3 minutes 
-Stop the flow from the ground hydraulic-cart. 
14) Depressurize the Green Hydraulic System, refer to AMM Task 29-10-00-864-001.
15) In the cockpit, move the L/G control lever to the DOWN position. 
(d) Restore the Landing Gear Extension/Retraction System. 
1) Move the MLG vent valve lever to the CLOSED position. 
2) Reconnect the MLG vent valve to the pushrod. Install the Bolt (item 4), the Bush 
(item 5), the Washer (item 6) and the Nut (item 7) Retained at removal (illustration 4).
3) Use Pin-Cotter MS24665-153 to Safety the nut Item (item 7) (illustration 4).
4) Move the LH MLG door opening handle to the OPEN position, refer to AMM Task 
32-12-00-010-001. 
5) Remove the Flight Ground Simulation Plates (98D32603000000) from the MLG door 
open proximity switches 32GA, 33GA, 34GA and 35GA (illustration 2). 
(e) Confirm Correct Reconnection of the MLG Free Fall Vent Valve: 
1) Make sure that the aircraft is correctly chocked. 
2) Release the Parking brake, refer to AMM Task 10-11-00-555-015. 
NOTE: The L/G freefall handle contacts the parking brake switch in the ON position.

### Page 20

Airbus Amber
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 20 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
3) In the cockpit, operate the L/G freefall handle. 
- Unstow the handle and operate 3 full turns in a clockwise direction.
4) At the MLG vent valve make sure that: 
- The MLG vent valve lever operates and moves to the OPEN position. 
5) In the cockpit, reset the L/G freefall handle: 
- Operate the handle 3 full turns in an anti-clockwise direction, then return the 
handle to the stowed position. 
6) At the MLG vent valve make sure that: 
- The MLG vent valve lever operates and moves to the CLOSED position. 
7) Check that the rigging holes align on the following Free Fall System equipment, 
Refer to AMM Task 32-00-00-860-003: 
-The three-landing gear uplocks 
-The three-landing gear door uplocks 
-The two landing gear vent valves 
-The landing gear cut - out valve. 
8) Select the parking brake to ON.
(3) TEST
(a) Do the test procedure, refer to AMM Task 32-12-00-710-002. 
(b) Do the preparation for test procedures as specified in the Installation of the MLG Door 
Actuating Cylinder, refer to AMM Task 32-31-35-400-001. 
(c) Do the test procedures as specified in the Installation of the MLG Door Actuating Cylinder, 
refer to AMM Task 32-31-35-400-001.
(4) CLOSE-UP
(a) Do the ’Check of the Filters in the Green Hydraulic System’ procedure, as specified in the 
’Check of the Clogging Indicators of the Hydraulic System Filters (Other than the two Case 
Drain Filters of the Engine-Driven Pumps), refer to AMM Task 29-10-00-210-002. 
(b) Check that the hydraulic fluid level in the Green System hydraulic reservoir is correct, refer 
to AMM Task 29-10-00-200-001. 
(c) Remove the False Targets from the weight on wheels proximity switches 20GA, 21GA, 
22GA, 23GA, 24GA and 25GA (Illustration 1). 
(d) Apply corrosion protection to the connectors of the LH and RH swivel joint assemblies 
(2763GM and 2764GM) and the adjacent areas, refer to AMM Task 51-75-13-916-002. 
(e) Do the Close-Up procedure as specified in AMM Task ’Installation of the MLG Door 
Actuator’, refer to AMM Task 32-31-35-400-001. 
(f) Remove the safety devices from the landing gear, refer to AMM Task 32-00-00-081-001. 
(g) Disconnect the hydraulic power cart and remove away from the aircraft. 
(h) Make sure that the work areas are clean and clear of tools and other items of equipment. 
(i) Put the aircraft back to its initial configuration.

### Page 21 (OCR)

Airbus Amber
AIRBUS
ALERT OPERATORS TRANSMISSION - AOT
2731  MLG EXTENSION
PROXIMITY-SENSOR
| 23GA
[(22GA)
MLG EXTENSION
PROXIMITY-SENSOR
• 21GA
NG EXTENSION
ROXIMITY-SENSOR
25GA
NG EXTENSION
PROXIMITY-SENSOR
NO D
IH SYMMETRICAL
Illustration 1 - MLG Extension Proximity Sensor
SENSOR
33GA
(32GA)  - B
35GA
TARGET  (34GA)
B C
LH SHOWN
RH SYMMETRICAL  TYPICAL
Illustration 2 - MLG Door Open Proximity Sensor
AOT ref: A32N033-24 Rev 00  Page 21 of 22  Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0  © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT

### Page 22

Airbus Amber
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A32N033-24 Rev 00 Page 22 of 22 Date: 29-OCT-2024
C80_AOT_FM1104649_v9.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
Illustration 3 - Flushing of the MLG Door Actuator Pipelines
 
Illustration 4 - MLG Door Actuator Pipelines

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.