# Airbus All Operators Transmission A25N019-19

Copy: No revision named ("AOT A25N019-19"), 6 pages: PDF https://openairdocs.org/files/sha256/c0/65/c065d2fbfaf93814a960fb0914077f1366457c58931145bdbb1fbf3866c8b285; text https://openairdocs.org/service-documents/airbus/aot-a25n019-19/file/c065d2fbfaf9.md. Rights: © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2019-1080, the docket of AD 2020-01-17. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Airbus](https://openairdocs.org/service-documents/airbus.md)
- Type: Other document (All Operators Transmission)
- Number: A25N019-19
- Page: https://openairdocs.org/service-documents/airbus/aot-a25n019-19

## Text (6 pages)

Rights: © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2019-1080, the docket of AD 2020-01-17. Not covered by OpenAirDocs’ CC0 dedication. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

CUSTOMER SERVICES DIRECTORATE
2 ROND POINT EMILE DEWOITINE
31700 BLAGNAC FRANCE
TELEPHONE + 33 (0)5 61 93 33 33
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A25N019-19 Rev 00 Page 1 of 6 Date: 23-DEC-2019
© AIRBUS S.A.S. 2019. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
SUBJECT: ATA 25 – Slide raft and Escape slide reservoir pressure check
AIRCRAFT TYPE: A318,A319,A320,A321
OUR REF.: A25N019-19 Rev 00 dated 23-DEC-2019
1. AIRCRAFT AFFECTED
All A320 family aircraft equipped with slide raft and escape slide Part Numbers (PN), listed below, except 
the aircraft with inflation reservoir connected to CABIN INTERCOMMUNICATION DATA SYSTEM 
(CIDS).
PN details:
The Rupture Disc Assembly, PN B14268-1, installed on inflation valves, on the slide manufactured from 
April 2017 to March 2019 (included) installed on:
Slide PN: D30664-513, -515, -609, -709, and -711
Slide PN: D30665-513, -515, 609, and -709
The Rupture Disc Assembly, PN B14268-1, installed on inflation valves, on the slide manufactured from 
May 2017 to September 2018 (included) installed on:
Slide PN: D31516-717, -719, and -721
Slide PN: D31517-717, -715, and -721
The Rupture Disc Assembly, PN B14268-1, installed on inflation valves, on the reservoir manufactured 
from May 2017 to June 2018 (included) installed on:
Reservoir PN: 61639-203
The Rupture Disc Assembly, PN B14268-1, installed on inflation valves, on the reservoir manufactured 
from March 2018 to May 2018 (included) installed on:
Reservoir PN: 70197-101
The Rupture Disc Assembly, PN B14268-1, installed on inflation valves, on the reservoir manufactured 
from February 2018 to June 2018 (included) installed on:
Reservoir PN: 70200-101, -102, -103, -104
The above PNs are installed on the following locations:
Location PN
Slide Raft, FWD door D30664-515, -609, -709, and -711
Wide Slide, FWD door D30664-513
Slide Raft, AFT door D30665-515, 609, and -709
Wide Slide, AFT door D30665-513,
Slide, FWD door D31516-717, -719, and -721
Slide, AFT door D31517-717, -715, and -721
Reservoir, door 2 and 3, A321 CEO/NEO 61639-203
Reservoir, door 3 LH/RH, A321 NEO ACF 70197-101
Reservoir, offwing slide, LH A321 NEO ACF, cargo compartment 70200-101
Reservoir, offwing slide, RH A321 NEO ACF, cargo compartment 70200-102
Reservoir, offwing slide, LH A321 NEO ACF, Overhead storage 
compartment (OHSC)
70200-103
Reservoir, offwing slide, RH A321 NEO ACF, OHSC 70200-104

### Page 2

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A25N019-19 Rev 00 Page 2 of 6 Date: 23-DEC-2019
© AIRBUS S.A.S. 2019. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
Locations of the slides, to be visually inspected at repetitive interval as per this AOT:
Aircraft Standard Door 1 Door 2 Door 3 Door 4
ST1: A320 X X
ST2: A321 X X X X
ST3: A319 X X
ST4: A318 X X
ST5: A320 NEO X X
ST6: A321 NEO X X X X
ST7: A319 NEO X X
ST8: A321 NEO ACF X X X
2. REFERENCED DOCUMENTATION
2.1 APPENDIX
- MODs list introducing inflation reservoir connected to CIDS. Ref: MODs list.xlsx
- Ref: AOT Flow Chart
2.2 REFERENCES
Ref. 1: AMM Task ref 25-62-00-210-001-A - Check Door and Offwing Escape Slide/Raft Inflation 
Reservoir Pressure
Ref. 2: AMM ref 25-62-44-04 CONF 00 - Slide - Escape, FWD AND AFT - Removal/Installation
Ref. 3: AMM ref 25-62-46-04 CONF 00 - Reservoir - Inflation, Offwing Escape Slide- 
Removal/Installation 
Ref. 4: AMM ref 25-62-49-04 CONF 00 - Reservoir - Inflation, Door 2/3 - Removal/Installation
Ref. 5: MPD Task ref 256241-01-1- Door Escape Slide- Check Door/Emergency Exit/Off wing Escape 
Slide/Raft Inflation Reservoir Pressure
Ref. 6: MMEL 25-62-01 Cabin Door Slide or Slide Raft
Ref. 7: MMEL 25-62-02 Cabin Overwing Exit Slide
Ref. 8: CCOM 14-030 EMERGENCY CABIN EVACUATION
3. REASON
This AOT is issued to inform the A320 family operators about possible findings of pressure depletion on 
emergency slide and to request repetitive pressure checks of the slide reservoir.
All slide reservoirs installed (affected slide PN are mentioned in this AOT, section 1. AIRCRAFT 
AFFECTED>>> PN details) on aircraft are concerned by this AOT.

### Page 3

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A25N019-19 Rev 00 Page 3 of 6 Date: 23-DEC-2019
© AIRBUS S.A.S. 2019. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
3.1 FACTS
The rupture disc assembly is part of a safety feature installed in the slide pressure reservoir valve, which 
is activated in high pressure conditions and releases gas to prevent the reservoir from being damaged 
under high pressure conditions. The burst disc has a pre-defined value at which it is activated (approx. 
4200 - 5000 psig at 160° F).
One instance of loud bang on aircraft from the field was reported and was confirmed resulting from the 
activation of the rupture disc fitted on the slide reservoir.
In the reported case, the inspection team found the slide reservoir pressure indicating “Zero” pressure. 
Investigation has shown that the rupture disc assemblies manufactured between April 2017 and March 
2019 could potentially be activated below their designed activation pressure of 4200 – 5000 psig at 160°F.
There is a MPD Ref. 5 to check the slide reservoir pressure every 12 months or 1000 FC.
Figure1: Example of the location of Rupture Disc on reservoir
3.2 CONSEQUENCES
The failure of the rupture disc will result in a sudden loss of the reservoir pressure and the slide will remain 
unusable. Slide with depleted gas reservoir will not function in case of emergency as per CCOM Ref. 8.
3.3 AIM
The aim of this AOT is to recommend repetitive visual inspections of the reservoir pressure of the slide, 
installed on the aircraft, pending the replacement of the affected rupture disc has been performed, when 
VSB is available.
4. SHORT TERM ACTION
All the A320 family operators having slide raft or escape slide (except for the offwing emergency exit door) 
not connected to CIDS for pressure monitoring in Flight Attendant Panel (FAP) are recommended to 
perform repetitive visual inspections of reservoir pressure in accordance with AMM Ref. 1.
The interval of the repetitive check is 50 days or 100 Flight Cycles (FC), whichever occurs first.

### Page 4

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A25N019-19 Rev 00 Page 4 of 6 Date: 23-DEC-2019
© AIRBUS S.A.S. 2019. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
NOTE: This AOT is expected to be classified mandatory by an equipment Airworthiness Directive (AD) 
with the VSB from Safran to replace the rupture disc. The accomplishment instructions marked as 
Required for Compliance (RC) must be done to comply with the AD. “RC” is indicating these paragraphs 
accordingly. 
NOTE: The accomplishment instructions of this AOT include procedures given in other documents or in 
other sections of the AOT. When the words ’refer to’ are used and the operator has a procedure accepted 
by the local authority he belongs to, the accepted alternative procedure can be used. When the words ’in 
accordance with’ are used then the given procedure must be followed.
NOTE: The access and close-up instructions, not comprising return to service tests, in this AOT do not 
constitute or affect the technical intent of the AOT. Operators can therefore, as deemed necessary, omit 
or add access and/or close-up steps to add flexibility to their maintenance operations as long as the
technical intent of the AOT is met within the set parameters.
4.1 PLANNING AND MANPOWER
4.1.1 RC - ACCOMPLISHMENT TIMESCALE
Airbus recommends to perform repetitive visual inspections of reservoir pressure of all the slides (not 
connected to CIDS for pressure monitoring in FAP) installed on the aircraft after the 50 days or 100 FC, 
whichever occurs first for all affected aircraft, from the date of issuance of this AOT.
Repetitive inspection: Each 50 days or 100 FC, whichever occurs first.
4.1.2 MANPOWER
The estimated time to perform inspection on one slide is 0.10 M/H
4.2 DESCRIPTION
To perform this AOT, the AMM Ref. 1 should be applied on the slide installed on the aircraft (affected 
slide PN are mentioned in this AOT, section 1. AIRCRAFT AFFECTED>>> PN details) at the location 
listed below:
Standard Door 1 Door 2 Door 3 Door 4
ST1: A320 X X
ST2: A321 X X X X
ST3: A319 X X
ST4: A318 X X
ST5: A320 NEO X X
ST6: A321 NEO X X X X
ST7: A319 NEO X X
ST8: A321 NEO ACF X X X
For the offwing emergency exit door, the slide inflation reservoir is connected to CIDS and the low 
pressure warning is displayed on the FAP. Hence, no repetitive visual check is required. In case of slide 
reservoir low pressure indication on the FAP, a removal and installation of the reservoir in accordance 
with AMM Ref. 3 is required.
Refer to AOT flow chart for inspection/action to be carried out as per this AOT.

### Page 5

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A25N019-19 Rev 00 Page 5 of 6 Date: 23-DEC-2019
© AIRBUS S.A.S. 2019. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
4.2.1 ACCESS
As per AMM Ref 1.
4.2.2 RC – INSPECTION REQUIREMENTS
Visual inspection in accordance with AMM Ref. 1, as per applicability of the MSN.
4.2.3 RC - FINDINGS
In case of slide reservoir pressure not found in line with AMM Ref. 1, either apply MMEL Ref. 6 or MMEL 
Ref. 7 or replace the slide or reservoir prior next flight as per:
AMM Ref. 2 or
AMM Ref. 3 or
AMM Ref. 4,
depending on the door slide location.
In case of low pressure indication on the FAP, the cabin crew is required to inform the maintenance 
crew to check the affected slide reservoir pressure as per AMM Ref. 1 and to take the appropriate action 
as per findings.
However, this AOT will still be applicable on the replaced slide, if the new slide is still equipped with the 
affected rupture disc (i.e. VSB not applied).
4.3 SPARE AND TOOLING
Not Applicable
5. FURTHER INFORMATION
5.1 FOLLOW-UP PLAN
An EASA AD is anticipated. The AOT will be revised, when the VSB and VSIL will be issued.
5.2 IMPACTED DOCUMENTATION
Not Applicable
6. AOT APPROVAL
The technical content of this document is approved under the authority of DOA nr. EASA.21J.031.
7. REPORTING
Questions about this AOT are to be addressed to Airbus Customer Services through TechRequest on 
Airbus World, selecting Engineering Domain, Section Engineering Support and ATA 25-62/ Topic AOT 
A25N019-19 Slide raft and Escape slide reservoir pressure check
As per latest reporting policy (Ref to OIT 999.0018/16), inspection results (with or without findings) are to 
be addressed to Airbus Customer Services through the generic e-mail address:  
inspection.results@airbus.com.
Best Regards,

### Page 6

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A25N019-19 Rev 00 Page 6 of 6 Date: 23-DEC-2019
© AIRBUS S.A.S. 2019. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
Christian FREMONT
VICE PRESIDENT ENGINEERING SUPPORT
CUSTOMER SERVICES
Jean-Pierre GOMEZ
VICE PRESIDENT A320  PROGRAMME
CUSTOMER SERVICES

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.