# Airbus All Operators Transmission A25N027-23

Copy: Revision 1 ("AOT_A25N027-23_Rev1"), 9 pages: PDF https://openairdocs.org/files/sha256/ef/b7/efb7b674a91ef4d3b8b5fda6cee27c25aec40c426100ab2b72f0c1b893e16347; text https://openairdocs.org/service-documents/airbus/aot-a25n027-23/file/efb7b674a91e.md. Rights: © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2024-2025, the docket of AD 2024-23-09. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Airbus](https://openairdocs.org/service-documents/airbus.md)
- Type: Other document (All Operators Transmission)
- Number: A25N027-23
- Latest revision known: A25N027-23, Revision 1, dated February 26, 2024 (OpenAirDocs)
- Page: https://openairdocs.org/service-documents/airbus/aot-a25n027-23

## Text (9 pages)

Rights: © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2024-2025, the docket of AD 2024-23-09. Not covered by OpenAirDocs’ CC0 dedication. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A25N027-23 Rev 01 Page 1 of 9 Date: 26-FEB-2024
C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
SUBJECT: ATA 25 – Door 3 Escape slide and Offwing slide inflation reservoirs orifice fitting inspection
AIRCRAFT TYPE:  A321-200NX
OUR REF.: A25N027-23 Rev 01 dated 26-Feb-2024
OUR PREVIOUS REF.: A25N027-23 Rev 00 dated 16-Jan-2024
EFFECTIVITY DATE: 19-Jan-2024
0. REASON FOR REVISION
The reasons for the revision 01 of this AOT A25N027-23 are :
- to inform about EASA AD 2024-0048 release,
- to clarify the aircraft type applicability, 
- to enable the removal of the reservoir unit for rectification purpose off-wing, 
- to inform about the extension of the affected SN list within the revision 01 of Safran VSB Ref. 2 and 
Ref. 3, leading to additional work if the AOT instructions have been completed with the previous 
revision.
The revised paragraphs are indicated between ***BEG. REV*** and ***END REV***. 
1. AIRCRAFT AFFECTED
***BEG. REV***
This AOT is applicable on All A321NX aircraft (i.e. NEO / ST8), namely :
A321-251NX, 
A321-252NX, 
A321-253NX, 
A321-271NX, 
A321-272NX, 
equipped with Door 3 & Offwing Evacuation Systems inflation reservoirs Part Numbers (PN), listed 
below:
the Door 3 Evacuation Systems inflation reservoir PN 70197-101 with affected SN listed in Ref. 
2.
the Offwing Evacuation Systems inflation reservoirs PNs 70200-101, -102, -103, -104 with 
affected SN listed in Ref. 3.
For aircraft that have Airbus MOD 161964 and 161796 embodied in production, the inspection as 
required in the paragraph 5.4. INSPECTION does not need to be accomplished for affected parts 
installed on door 3 FIN 7693MM and 7694MM. 
The above PNs are installed on the following locations:
Location PN FIN
A321NX, LH Emergency exit door 3 slide reservoir, Overhead storage 
compartment (OHSC)
70197-101 7693MM
A321NX, RH Emergency exit door 3 slide reservoir, OHSC 70197-101 7694MM
A321NX, LH offwing slide reservoir, cargo compartment 70200-101 7683MM

### Page 2

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A25N027-23 Rev 01 Page 2 of 9 Date: 26-FEB-2024
C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
A321NX, RH offwing slide reservoir, cargo compartment 70200-102 7684MM
A321NX, LH offwing slide reservoir, OHSC 70200-103 7685MM
A321NX, RH offwing slide reservoir, OHSC 70200-104 7686MM
***END REV***
2. REFERENCED DOCUMENTATION
2.1 APPENDIX
Not applicable.
2.2 REFERENCES
***BEG. REV***
Ref. 1: EASA AD 2024-0048 - ATA 25 - Equipment/Furnishings - Escape Slide and Offwing Slide 
Inflation Reservoir Venting Holes - Inspection / Replacement
Ref. 2: SAFRAN VSB A321 005-25-45 Rev 01 “Inspection/Replacement of Contaminated Orifice Fitting 
P/N M3SP-303-004-E” for Door 3 Evacuation Systems manufactured by Air Cruisers
Ref. 3: SAFRAN VSB A321 005-25-46 Rev 01 “Inspection/Replacement of Contaminated Orifice Fitting 
P/N M3SP-303-004-E” for Offwing Evacuation Systems manufactured by Air Cruisers
Ref. 4: AMM task 25-62-49-000-001-A - Removal of the Door 3 Escape-Slide Inflation Reservoir
Ref. 5: AMM task 25-62-46-000-001-A - Removal of the Inflation Reservoir for the Offwing Escape Slide
Ref. 6: AMM task 25-62-00-481-001 - Special Precautions before You Do Work on 
the Offwing/Emergency-Exit-Door Escape-Slide Systems
Ref. 7: AMM task 25-62-00-081-001 - Special Precautions after You Do Work on the 
Offwing/Emergency-Exit-Door Escape-Slide Systems
Ref. 8: AMM task 25-62-49-400-001-A - Installation of the Door 3 Escape-Slide Inflation Reservoir
Ref. 9: AMM task 25-62-46-400-001-A - Installation of the Inflation Reservoir for the Offwing Escape 
Slide
Ref. 10: ISI article Ref. 25.62.00054
3. REASON
This AOT is issued to advise the A321NX operators about a quality escape detected on A321NX Door 
3 & Offwing inflation reservoirs’ venting holes [a torque strip indicator (material “Dykem”) has been 
applied on the orifice fitting] and to request the rectification of the inflation reservoir regulator valve.
All slide reservoirs installed (affected slide PN and FIN are mentioned in this AOT, paragraph 1. 
AIRCRAFT AFFECTED, for affected SN refer to Ref. 2 and Ref. 3) on aircraft are concerned by this 
AOT.

### Page 3

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A25N027-23 Rev 01 Page 3 of 9 Date: 26-FEB-2024
C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
All spare parts (for affected SN refer to Ref. 2 and Ref. 3) shall be inspected in accordance with Ref. 2 
and Ref. 3 instructions prior installation on aircraft.
***END REV***
3.1 FACTS
The orifice fitting in the pneumatic system, P/N M3SP-303-004-E, is a redundant feature to vent an 
accumulation of pressure from a potential leak of inflation gas from the outlet of the inflation regulator 
valve.
A torque strip indicator (material “Dykem”) has been applied on the orifice fitting.
This may lead to an unintended deployment of the evacuation slide in flight.
A number of systems with a clogged orifice fitting are suspected having been shipped from the supplier 
factory.
3.2 HISTORY/BACKGROUND
*** BEG. REV***
The evacuation systems, installed on A321NX Emergency exit Door 3 and Offwing door, is fitted with 
venting features which ensure redundancy to vent gas leakage accumulation as seen in below Figures 
1 and 3:
the packed slide system is incorporating a check valve,
the reservoir regulator valve outlet port is fitted with an orifice fitting.
   
Figure 1: Example of the location of the orifice fitting on the reservoir

### Page 4

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A25N027-23 Rev 01 Page 4 of 9 Date: 26-FEB-2024
C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
***END REV***
3.3 ROOT CAUSE
A torque strip indicator (Material “Dykem”) has been applied on the orifice fitting as described in Figure 
2.
This torque strip indicator may clog the venting hole. 
Figure 2: Example of the orifice fitting on the reservoir with strip indicator applied
3.4 INVESTIGATION 
Investigation in supplier’s production has revealed such a clogged orifice fitting.
3.5 CONSEQUENCES
As per Figure 3 below, if gas leakage accumulates from the reservoir regulator valve, whilst there is no 
capability of venting the gas, there is a risk of slide enclosure door panel release and soft cover opening 
during flight.
Indeed, if the slide pneumatic piping system is unexpectedly pressurized, there is a risk of activation of 
both the enclosure ball locks and locking lacing cover actuator.
Nevertheless, gas leakage accumulation will not trigger the activation of the reservoir and therefore the 
inflation of the slide inflatable assy.

### Page 5

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A25N027-23 Rev 01 Page 5 of 9 Date: 26-FEB-2024
C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
 
Figure 3 : Slide Pneumatic System design
4. OBJECTIVES OF THIS AOT
This AOT recommends checking whether the Torque strip clogs the orifice fitting. 
*** BEG. REV***
In the case the “Dykem” marking is not present as per Figure 1, no rectification action is required.
*** END REV***
In the case the “Dykem” marking is present as per Figure 2, the orifice fitting shall be removed and 
replaced.
5. MAINTENANCE PROCEDURE
NOTE: This AOT is classified mandatory or expected to be classified mandatory by an Airworthiness 
Directive (AD). If the instructions of this AOT are marked as Required for Compliance (RC), the operator 
must follow the instructions as indicated. These instructions are introduced by “in accordance with”.
NOTE: The instructions of this AOT include procedures given in other documents or in other sections 
of the AOT. If the instructions of this AOT are NOT marked as Required for Compliance (RC), the 
operator can use an alternative procedure accepted by his/her local authority. These instructions are 
introduced by “refer to”.
NOTE: When this AOT gives the access or close-up instructions with no return to service tests, the 
operator can adapt these instructions to add flexibility to the maintenance operations. The technical 
intent of this AOT must comply with the set parameters.
5.1 PLANNING – (RC)
*** BEG. REV***
Airbus recommends to perform the inspection of the reservoir of the affected slides in accordance with 
Ref. 2 and Ref. 3 installed on aircraft within the next 04 months after 19-Jan-2024 (effective date of the 
AOT initial issue).
5.2 MANPOWER

### Page 6

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A25N027-23 Rev 01 Page 6 of 9 Date: 26-FEB-2024
C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
Referring to Ref. 2 and Ref. 3, inspection of systems, including aircraft preparation and time to gain 
access, will take approximately 0.25 hour for each affected unit, and the accomplishment of Ref. 2 or 
Ref. 3 will take approximately 0.25 hour for each affected unit.
NOTE: When launching this inspection, it is recommended to make sure that sufficient time is available 
before the next flight, to perform the corrective action in case of finding.
5.3 ACCESS
Refer to AMM tasks Ref. 4 for Door 3 Escape slide reservoir and Ref. 5 for Offwing slide reservoir.
Put the ACCESS PLATFORM 2M (6 FT) in position below the aft cargo-compartment door.
5.4.INSPECTION – (RC)
To perform this AOT, the operators are required to identify the potentially affected inflation reservoirs in 
accordance with Ref. 2 and Ref. 3: 
- using applicable maintenance records, 
AND/OR 
- by visual inspection of the inflation reservoirs installed on aircraft, 
AND/OR 
- using spare stock listing/records.
For the identified reservoirs, the operators are required to inspect the orifice fitting for the presence of 
"Dykem" marking applied to the top surface (example of “Dykem” application shown in Figure 2). 
5.5 FINDINGS – (RC)
On the identified reservoir units : 
If “Dykem” marking is present on the orifice fitting, apply the rectification instructions provided 
within paragraph 5.6 INSTRUCTIONS – (RC). 
If “Dykem” marking is not present, no rectification is required and the marking identification 
instructions are to be accomplished in accordance with Ref. 2 or Ref. 3.
5.6 INSTRUCTIONS – (RC)
A. Spare parts rectification
(1) For Door 3 Evacuation Systems : Remove and discard the marked orifice fitting. Install new orifice 
fitting P/N M3SP-303-004-E with a dedicated socket wrench in accordance with Ref. 2.
Installation torque of new fitting is detailed in Ref. 2. for A321NX Door 3 Evacuation Systems inflation 
reservoirs PN 70197-101.
(2) For Offwing Evacuation Systems : Remove and discard the marked orifice fitting. Install new orifice 
fitting P/N M3SP-303-004-E with a dedicated socket wrench in accordance with Ref. 3.

### Page 7

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A25N027-23 Rev 01 Page 7 of 9 Date: 26-FEB-2024
C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
Installation torque of new fitting is detailed in Ref. 3. for A321NX Offwing Evacuation Systems inflation 
reservoirs PNs 70200-101, -102, -103, -104.
(3) Ensure that the green dot and black marking identification is done on the identified reservoir unit in 
accordance with Ref. 2 or Ref. 3.
B. On-wing rectification of A321NX Door 3 Evacuation Systems inflation reservoirs
***END REV***
WARNING:
MAKE SURE THAT THE LOCK PIN IS CORRECTLY INSTALLED IN THE REGULATOR VALVE 
ASSEMBLY OF THE INFLATION RESERVOIR. THIS SAFETIES ALL COMPONENTS OF THE 
INFLATION SYSTEM IN OPERATION AND PREVENTS ACCIDENTAL:
DISCHARGE OF THE INFLATION RESERVOIR
DEPLOYMENT OF THE ESCAPE SLIDE
WHICH CAN CAUSE INJURY AND/OR DAMAGE.
WARNING:
MAKE SURE THAT YOU TURN THE REGULATOR ASSEMBLY IN A CLOCKWISE DIRECTION 
OR IN THE DIRECTION OF THE BLACK MARK. WHEN YOU TURN THE REGULATOR 
ASSEMBLY IN THIS DIRECTION, THE VALVE CLOSES.
IF YOU DO NOT OBEY THIS INSTRUCTION, YOU WILL START AN UNWANTED DEPLOYMENT 
SEQUENCE.
THIS CAN CAUSE INJURY TO PERSONNEL AND DAMAGE TO EQUIPMENT.
*** BEG. REV***
(1) Do the special precautions before you work on the escape slide system(s) in accordance with Ref. 
6.
CAUTION:
ESCAPE-SLIDE INFLATION RESERVOIR MAY DISCHARGE IF LOCK PIN IS NOT INSTALLED.
- Ensure the lock pin assembly is installed in the regulator valve assembly of the inflation reservoir.
(2) Remove and discard the marked orifice fitting. Install new orifice fitting P/N M3SP-303-004-E with a 
dedicated socket wrench in accordance with Ref. 2.
Installation torque of new fitting is detailed in Ref. 2. for A321NX Door 3 Evacuation Systems inflation 
reservoirs PN 70197-101.
NOTE : The new orifice fitting can be installed on the affected reservoir either on-wing or after removal 
from the aircraft in accordance with Ref. 4. 
The replacement by a serviceable part is also an acceptable means of compliance to the AOT 
instructions.
(3) Ensure that the green dot and black marking identification is done on the identified reservoir unit in 
accordance with Ref. 2.
(4) Do the special precautions after you worked on the escape slide system(s) in accordance with Ref. 
7.
CAUTION:

### Page 8

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A25N027-23 Rev 01 Page 8 of 9 Date: 26-FEB-2024
C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
MAKE SURE THAT THE LOCK PIN IS REMOVED FROM THE REGULATOR VALVE ASSEMBLY 
OF THE INFLATION RESERVOIR. IF IT IS NOT REMOVED, IT CAN PREVENT THE INFLATION 
OF THE ESCAPE SLIDE/RAFT.
- Ensure the lock pin assembly is removed from the regulator valve assembly of the reservoir and 
installed in the pocket.
(5) Remove the safety clip(s) and tag(s) if installed, close the circuit breaker(s) if previously opened and 
do the “5. Close-up” paragraph with reference to Ref. 8.
C. On-wing rectification of A321NX Offwing Evacuation Systems inflation reservoirs
***END REV***
WARNING:
MAKE SURE THAT THE LOCK PIN IS CORRECTLY INSTALLED IN THE REGULATOR VALVE 
ASSEMBLY OF THE INFLATION RESERVOIR. THIS SAFETIES ALL COMPONENTS OF THE 
INFLATION SYSTEM IN OPERATION AND PREVENTS ACCIDENTAL:
DISCHARGE OF THE INFLATION RESERVOIR
DEPLOYMENT OF THE ESCAPE SLIDE
WHICH CAN CAUSE INJURY AND/OR DAMAGE.
WARNING:
MAKE SURE THAT YOU TURN THE REGULATOR ASSEMBLY IN A CLOCKWISE DIRECTION 
OR IN THE DIRECTION OF THE BLACK MARK. WHEN YOU TURN THE REGULATOR 
ASSEMBLY IN THIS DIRECTION, THE VALVE CLOSES.
IF YOU DO NOT OBEY THIS INSTRUCTION, YOU WILL START AN UNWANTED DEPLOYMENT 
SEQUENCE.
THIS CAN CAUSE INJURY TO PERSONNEL AND DAMAGE TO EQUIPMENT.
***BEG. REV***
(1) Do the special precautions before you work on the escape slide system(s) in accordance with Ref. 
6. 
CAUTION:
ESCAPE-SLIDE INFLATION RESERVOIR MAY DISCHARGE IF LOCK PIN IS NOT INSTALLED.
- Ensure the lock pin assembly is installed in the regulator valve assembly of the inflation reservoir.
(2) Remove and discard the marked orifice fitting. Install new orifice fitting P/N M3SP-303-004-E with a 
dedicated socket wrench in accordance with Ref. 3.
Installation torque of new fitting is detailed in Ref. 3. for A321NX Offwing Evacuation Systems inflation 
reservoirs PNs 70200-101, -102, -103, -104.
NOTE : The new orifice fitting can be installed on the affected reservoir either on-wing or after removal 
from the aircraft in accordance with Ref. 5. 
The replacement by a serviceable part is also an acceptable means of compliance to the AOT 
instructions.
(3) Ensure that the green dot and black marking identification is done on the identified reservoir unit in 
accordance with Ref. 3.
(4) Do the special precautions after you worked on the escape slide system(s) in accordance with Ref. 
7.

### Page 9

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A25N027-23 Rev 01 Page 9 of 9 Date: 26-FEB-2024
C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2024. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
CAUTION:
MAKE SURE THAT THE LOCK PIN IS REMOVED FROM THE REGULATOR VALVE ASSEMBLY 
OF THE INFLATION RESERVOIR. IF IT IS NOT REMOVED, IT CAN PREVENT THE INFLATION 
OF THE ESCAPE SLIDE/RAFT.
- Ensure the lock pin assembly is removed from the regulator valve assembly of the reservoir and 
installed in the pocket.
(5) Remove the safety clip(s) and tag(s) if installed, close the circuit breaker(s) if previously opened and 
do the “5. Close-up” paragraph with reference to Ref. 9.
5.7 SPARES AND TOOLING
Refer to Ref. 2 and Ref. 3 for necessary materials and tooling.
6. ADDITIONAL INFORMATION
ISI article Ref. 10 is available for further information.
6.1 FOLLOW-UP PLAN
This AOT has been classified Mandatory by the Ref. 1 released the 16 February 2024. 
The Ref. 1 has to be accomplished within 3 months after the effective date : 01 March 2024.
***END REV***
6.2 IMPACTED DOCUMENTATION
Not applicable.
7. AOT APPROVAL
The technical content of this document is approved under the authority of the DOA ref.EASA.21J.031.
8. REPORTING
Address your AOT embodiment status (with reservoir PN, SN and FIN location) to Airbus Customer 
Services through the generic e-mail address: inspection.results@airbus.com. Refer to the latest 
reporting policy (Ref in the OIT 999.0018/16).
Give the AOT reference in the mail title, as follows: { AOT A25N027-23} Embodiment status
You can address your questions about this AOT to Airbus Customer Services through TechRequest on 
Airbus World, selecting Engineering Domain Section Engineering Support and ATA 25-62 / Topic AOT 
A25N027-23 Escape slide and Offwing slide inflation reservoirs orifice inspection.
Best Regards,
Wolfgang WOHLERS
HEAD OF ENGINEERING AND MAINTENANCE
Jean-Pierre GOMEZ
VICE PRESIDENT A320 PROGRAMME
CUSTOMER SERVICES

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.