# Airbus All Operators Telex A340-25A5191

Copy: No revision named ("U.S. DOT/FAA - Service Information"), 5 pages: PDF https://openairdocs.org/files/sha256/5f/e7/5fe7d712399048914b4e12ae279aa760d805976be3845ad8ecb6317f84c86083; text https://openairdocs.org/service-documents/airbus/aot-a340-25a5191/file/5fe7d7123990.md. Rights: © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2012-0295; AD 2012-06-12 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Airbus](https://openairdocs.org/service-documents/airbus.md)
- Type: Other document (All Operators Telex)
- Number: A340-25A5191
- Page: https://openairdocs.org/service-documents/airbus/aot-a340-25a5191

## ADs that cite it (1) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2012-06-12](https://openairdocs.org/ad/2012-06-12.md), effective Apr 16, 2012: No revision named

## Text (5 pages)

Rights: © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2012-0295; AD 2012-06-12 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

ALL OPERATORS TELEX – ALL OPERATORS TELEX
SUBJECT: ATA 25 OFF-WING RAMP SLIDE SOFT COVER CLOSURE AND VENT VALVE
ACTIVATION INSPECTION
OUR REF: AOT A340-25A5191 dated 18 JAN 2011
1. AIRCRAFT AFFECTED
ALL A340-600 FROM MSN 371 TO MSN 1122 INCLUDED.
2. REFERENCED DOCUMENTATION
2.1 AMM 25-62-43-000-801 Removal of the Offwing Escape-Slide
2.2 AMM 25-62-43-400-801 Installation of the Offwing Escape-Slide
2.3 AMM FIGURE 25-62-43-991-00100 / SHEET 2/2 Escape-Slide Assembly
2.4 AMM 25-62-46-000-801 Removal of the Inflation Reservoir
2.5 AMM 25-62-46-400-801 Installation of the Inflation Reservoir
2.6 AMM FIGURE 25-62-46-991-00100 / SHEET 2/2 Inflation Reservoir Assembly
2.7 GOODRICH ALERT SERVICE BULLETIN 4A3931-25A400 revision 1
2.8 AIRBUS TECHNICAL FOLLOW-UP TFU 25.60.00.012
3. REASONS
3.1 FACTS
An A340-600 operator has reported the in-flight loss of the blow-out panel and the inflatable assembly
from an off-wing ramp-slide.
Investigation has not completely identified the root cause of the event.
However, the investigation has revealed the two main indicators of a potential slide loss, which are the
packboard soft covers not fully closed and the vent valve not activated.
3.2 CONSEQUENCES
In flight, the air contained in the inflatable assembly could increase in volume due to changes in air
pressure. As a result, pack growth could occur and apply loads on the packboard soft covers and the
blow-out panel attachment hardware.
A vent valve is used to balance pressure inside the inflatable with the ambient air pressure, and de-
activation of this vent valve could lead to pack growth. Analysis indicates that non activation of the
vent valve, followed by soft cover opening, could cause the packboard blow-out panel to separate
from the slide enclosure. The ramp slide might be pulled from its compartment by the aerodynamic
loads, which in turn could cause damage to the aircraft fuselage.
3.3 AIM
The aim of this AOT is to specify a one-time inspection of the soft cover condition and check of the
vent valve function on each off-wing ramp slide. If the soft covers are observed open or if the slide

### Page 2

release pin is not fully engaged and not correctly secured with safety tie, or if the vent valve
activation check is not successful, the ramp slide must be removed from the aircraft and restored.
4. SHORT-TERM ACTION
4.1 PLANNING AND MANPOWER
4.1.1 ACCOMPLISHMENT TIMESCALE
This one-time inspection as per paragraph 4.2 must be performed no later than 3 months from receipt
of this AOT.
For off-wing ramp slide spares, operators are requested to perform this one-time inspection as per
Goodrich Alert Service Bulletin 4A3931-25A400 revision 1 paragraph 3 "Accomplishment Instructions"
before installation on aircraft.
4.1.2 MANPOWER
As per Goodrich Alert Service Bulletin 4A3931-25A400 revision 1, the inspection of the off-wing ramp
slide can be either done on aircraft or in the workshop.
On-aircraft inspection :
Total man-hours per aircraft: 3 man-hours
Total man-hours per ramp slide: 1.5 man-hours
In-workshop inspection :
Total man-hours per ramp slide: 0.5 man-hour
(off-wing ramp slide removal is not considered)
Man-hours may vary depending upon the equipment unit conditions noted during the inspection.
4.2 DESCRIPTION
If the inspection is performed in the workshop, proceed as per instructions provided in the Goodrich
Alert Service Bulletin 4A3931-25A400 revision 1.
If the inspection is performed on the aircraft, proceed as follows :
WARNING: FOLLOW ALL WARNING AND CAUTION NOTES AND PROCEDURES IN THE
APPLICABLE AIRBUS AMM 25-62-43 PB401 WHEN PERFORMING THE
FOLLOWING WORK PROCEDURES.
4.2.1 Make sure that the emergency control-handle is set to the disarmed position and that the safety
pin is installed according to AMM task 25-62-43-000-801.
4.2.2 Put a warning notice in position to tell persons not to arm the door.
4.2.3 Put an access platform, 5 m (16 ft) – Adjustable in position adjacent to the applicable escape
ramp slide on one side of the aircraft.
4.2.4 Safety the applicable Main Landing Gear (MLG) door and flaps according to AMM task 25-62-
43-000-801.
4.2.5 Put a warning notice in position to tell persons not to operate the MLG doors or flaps.

### Page 3

4.2.6 Get access to the avionics compartment. Then open, safety and tag this (these) circuit
breaker(s):

PANELDESIGNATIONFINLOCATION
721VU SRPSU NORM 1NG N14
FOR FIN 7932MX (PRESSURE BOTTLE LH)
722VU CIDS; DEU B L FWD NORM    613RH A03
743VU CIDS DEU B L ESS 1415RH A95
FOR FIN 7933MX (PRESSURE BOTTLE RH)
722VU CIDS; DEU B R FWD NORM    614RH A04
743VU CIDS DEU B R ESS 1416RH A96
4.2.7 Put an access platform, 3 m (10 ft) – Adjustable in position in the wheel well to get access to
the inflation reservoir.
4.2.8 In the belly fairing, gain access to the off-wing reservoir assembly.
4.2.9 Install the safety pin in the regulator valve assembly of the inflation reservoir.
4.2.10 Disconnect the pressure hose connection from the inflation reservoir and put a blanking plug
on the disconnected line end according to AMM task 25-62-46-000-801.
4.2.11 Perform the inspection as per Goodrich Alert Service Bulletin 4A3931-25A400 revision 1
paragraph "Accomplishment Instructions" steps 3.A.(1) to 3.A.(8).
4.2.12 Record findings from paragraphs 4.2.11 on the survey sheet attached to the Goodrich Alert
Service Bulletin 4A3931-25A400 revision 1.
4.2.13 If an adverse finding is noted from paragraph 4.2.11, remove the off-wing ramp slide at fault
and install a serviceable ramp slide prior to the next flight, according to AMM task 25-62-43-400-801.
NOTE: Any adverse condition(s) present on the slide unit can be rectified per Goodrich Alert
Service Bulletin 4A3931-25A400 revision 1, paragraph 3.H.
4.2.14 Remove the blanking plug from the disconnected line end. Connect the pressure hose
connection to the inflation reservoir according to AMM task 25-62-46-400-801.
4.2.15 Move the access platform to the other side of the aircraft and repeat the steps 4.2.1 to 4.2.14.
4.2.16 Put the Aircraft back to its Initial Configuration according to AMM task 25-62-43-400-801.
4.2.17 Make sure the safety pin is removed from the regulator valve assembly of the inflation
reservoirs.
4.2.18 Get access to the avionics compartment. Then remove the safety clip(s) and the tag(s) and
close this(these) circuit breaker(s): 1NG, 613RH, 1415RH, 614RH and 1416RH.
4.2.19 Remove the warning notices.
4.2.20 Remove the ground support and maintenance equipment, the special and standard tools and
all other items.

### Page 4

4.3 MATERIAL-TOOLING
- Access Platform, 5 m (16 ft) – Adjustable
- Access Platform, 3 m (10 ft) – Adjustable
- Refer to Airbus AMM tasks 25-62-43-000-801 and 25-62-46-400-801
- Refer to Goodrich Alert Service Bulletin 4A3931-25A400 revision 1.
5. FURTHER ACTION
The associated Goodrich Packing Instructions have been revised to introduce the vent valve
activation check procedure to ensure correct vent valve functioning after off-wing ramp slide packing
completion.
The Technical Follow-Up TFU 25.60.00.012 will provide operators with investigation results and
associated solution status.
Inspection findings reported to Airbus will allow Airbus and Goodrich to review and further determine
the root cause of this issue.
6. AOT APPROVAL
The technical content of this AOT has been approved under EASA Design Organisation Approval
EASA.21J.031.
It is anticipated that this AOT will be rendered mandatory by issuance of an EASA Airworthiness
Directive.
7. RECORDING/ACKNOWLEDGMENT
Operators are requested to acknowledge receipt of this AOT to:
Mrs. V. HOLDEN, SEE
E-mail: valerie.holden@airbus.com
Fax number +33 (0)5 61 93 44 25
Within 48 hours after receipt. This acknowledgement can be made through the Airbus RCSR office
when available.
This acknowledgement can be made through the Airbus RCSR office when available.
Operators are requested to report inspection findings to:
Mr. M. ALAHYANE, SEEC2
Phone: +33 (0)5 67 19 73 12
Fax number +33 (0)5 61 93 44 25
E-mail: mohamed.alahyane@airbus.com
Philippe GOURDON
VICE PRESIDENT A330/A340 PROGRAMME
CUSTOMER SERVICES DIRECTORATE

### Page 5

If you receive this message via e-mail/internet, we draw your attention to the fact that it may be
monitored and/or intercepted. Further, whilst Airbus has taken reasonable measures to ensure the
integrity of this message and its contents, no warranty, whether express or implied is given that the
contents hereof conform to the original. In case of any doubt, please, retrieve this document from
your SITA address or AirbusWorld or request that it be retransmitted by fax or telex.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.