# Airbus All Operators Transmission A340-27A4181

Copy: No revision named ("U.S. DOT/FAA - Service Information - 1"), 7 pages: PDF https://openairdocs.org/files/sha256/bd/8b/bd8ba17f65a427434037430dce4636f3a555ba48257183a8e565faaca2c341a9; text https://openairdocs.org/service-documents/airbus/aot-a340-27a4181/file/bd8ba17f65a4.md. Rights: © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2012-0995; AD 2012-25-10 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Airbus](https://openairdocs.org/service-documents/airbus.md)
- Type: Other document (All Operators Transmission)
- Number: A340-27A4181
- Page: https://openairdocs.org/service-documents/airbus/aot-a340-27a4181

## ADs that cite it (2) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2014-15-09](https://openairdocs.org/ad/2014-15-09.md), effective Sep 5, 2014: No revision named
- [AD 2012-25-10](https://openairdocs.org/ad/2012-25-10.md), effective Jan 31, 2013: No revision named

Also cited in [2 proposed ADs](https://openairdocs.org/service-documents/airbus/aot-a340-27a4181/proposed.md).

## Text (7 pages)

Rights: © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2012-0995; AD 2012-25-10 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. This text is OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1 (OCR)

ALL OPERATORS TELEX - ALL OPERATORS TELEX
SUBJECT: ATA 27 - SPOILER SERVO CONTROLS - LOSS OF THE HYDRAULIC LOCKING
FUNCTION
OUR REF: AOT A340-27A4181 dated 04 January 2012
1. AIRCRAFT AFFECTED
All A340-200 and A340-300 in-service aircraft fitted with MZ-type Spoiler
Servo Controls (SSC), Part Number (PN) MZ4339390-12 or PN MZ4306000-12.
2. REFERENCED DOCUMENTATION
- Ref.1: Liebherr Component Maintenance Manual (CMM) 27-64-52 Figure 4
Item 210 - Blocking Valve
- Ref.2: Liebherr CMM 27-64-52 Figure 4 Item 140 - Maintenance operator
Mechanism
- Ret.3: Liebherr CMM 27-64-52 Figure 4 Item 190 - Seal
- Ref.4: Airbus Service Bulletin (SB) A340-27-4115 - Flight Controls -
Spoiler - Introduce operator mechanism cover
EASA Airworthiness Directive (AD)  2008-0160 - Flight Controls -
Spoiler Servo Control Maintenance Cover - Identification / Modification
- Ref. 6: FAA AD 2009-18-20
- Ref.7: Aircraft Maintenance Manual (AMM) Task 27-64-00-710-802 -
Operational Test of the Hydraulic Locking Function on the Spoiler Servo
- Ref.8: AMM 27-64-52 PB 401 - Servo Control - Spoiler 2,3,4,5,6 - Removal
/ Installation
- Ref. 9: AMM 27-64-51 PB 401 - Servo Control - Spoiler 1 - Removal /
Installation
- Ref. 10: Master Minimum Equipment List (MMEL) item 29-09-01 - HYD G(B) (Y)
ELEC PUMP FAULT Alert,  dated 16 December 2011
- Ref. 11: MMEL item 29-20-04 - Yellow Auxiliary Hydraulic power
(Electrical Pump), dated 16 December 2011
- Ret. 12: Airbus Reporting Sheet RS-SEEL6-2011-686000
- Ref.13: Liebherr-Aerospace Information Notice reference AER/CS/1107-13
- Ref.14: Airbus Technical Follow Up (TFU) 27.64.00.013 - Spoiler SC MZ
type - Loss Of Hydraulic Locking Function
3. REASON
3.1. FACTS
Two operators have reported several spoilers not remaining in the retracted
position after manual  depressurization of the corresponding hydraulic
circuit during test flights.
Subsequent checks on ground confirmed that, for each affected spoiler
surface:
- The spoiler was fitted with one MZ-type SSC (PN MZ4339390-12 or PN
MZ4306000-12)
- The maintenance operator mechanism of the SSC was confirmed in the
'o' (operation) position (hydraulic locking function operative).
Nevertheless, the spoiler surface could be manually extended.
3.2. SYSTEM DESCRIPTION
Page 1

### Page 2 (OCR)

Each aircraft is fitted with six pairs of spoilers, identified from
position 1 (inboard) to 6 (outboard).
Each SSC is  controlled by a single flight control computer and supplied by
one hydraulic circuit:
- Positions 1(13C1/13CS2) and 5 (17CS1/17C2) supplied by Green (G)
circuit.
- Positions 2 (14cs1/14CS2) and 3 (15CS1/15CS2) supplied by Blue (B)
Circsitions 4 (16CS1/16CS2) and 6 (18CS1/18CS2) supplied by Yellow (Y)  circuit.
SSCs installed in position 1 are not interchangeable with the remaining 2
to 6 ssc positions since the length of the stroke is different.
the are at harack ice dunction ation revents the extension of the spoiler  whose purpose is to ensure
- If the depressurization occurs when the spoiler is retracted, the SSC
remains locked in position.
If the depressurization occurs when the spoiler is  extended, the
blocking valve allows the retraction under aerodynamic loads.
In addition to the blocking valve ref.1, the ssc is fitted with a
maintenance operator mechanism ref.2, which allows the de-activation of the
locking function for maintenance purposes.
During normal operation, the maintenance operator mechanism is set to the
'o' (Operation) position, and the hydraulic locking function is operative.
when the maintenance operator mechanism is set to the 'M' (Maintenance)
position, the hydraulic locking function is de-activated, and the spoiler
can be manually extended for maintenance purposes.
3.3. INVESTIGATIONS
3.3.1 SHOP FINDINGS
The investigation of the affected SSCs at Liebherr revealed that the loss
of the hydraulic locking  function was due to an internal leakage caused by
a sheared seal ref.3. This seal is installed at the left end of the
blocking valve ref.1.
3.3.2 PREVIOUS MODIFICATION
From 2008 to 2010, all MZ-type SSCs were modified to the current PN
MZ4539390-12 (position 1)  and PN MZ4306000-12 (position 2 to 6) as per
ref.4 Airbus SB. This modification was mandated by ref.5 and ref. 6 ADs.
3.3.3 SUSPECTED ROOT CAUSE
Most MZ-type SSCs were modified on-wing. During this on-wing modification,
che rer.¿ maintenance operator mechanism was removed,  allowing a possible
untimely migration of the ref.1 blocking valve out of its groove.
It is suspected that this untimely migration is the root cause for the
sheared ref. 3 seal events.
3.4. CONSEQUENCES
Page 2

### Page 3 (OCR)

As long  as the corresponding hydraulic circuit is pressurized, this failure
as no impact on the operation of the spoilers.
in case of loss of the hydraulic locking function, the sSC is
o longer able to remain in the retracted position in the event of a
depressurization of the related hydraulic circuit. Therefore, the spoiler
surface would extend up to the zero-hinge moment position, which mainly
depends on the aircraft speed and on the Flap/Slat configuration.
This failure mode (internal leakage)  cannot be detected by the flight
control computers monitoring,  and will remain as hidden until the
ssociated hydraulic system is depressurized in flight. Should an untimely
deflection in flight occur,  this is announced to the crew via the ECAM
varning F/CTL SPLR FAULT and the F/CTL Page on the System Display.
functional repliesure he testificate fail ki
3.5. AIM
The aim of this AOT is to confirm the reliable functioning of the MZ-type
sSCs currently installed on aircraft by means of a one-time test as per the
new ref. 7 AMM task.
It is anticipated that this AOT will be rendered mandatory by an EASA AD.
4. REQUIRED ACTION
4.1. PLANNING AND MANPOWER
The following corrective plan needs to be performed, as per paragraph 4.2,
on all in-service affected aircraft:
- Within 90 days from receipt of this AOT:
* Identification of the concerned aircraft
* Test of the MZ-type SSC(s)
- In case of findings:
Corrective actions to be accomplished before further flight on the
SSCs related to the Blue hydraulic  * Corrective actions to be accomplished within 24 months on the SSCs  : circuit
related to the Yellow and Green hydraulic systems
- Reporting within 30 days after accomplishment of the corrective
actions
Spare units are not affected by the requirements of this AOT,  because the
hydraulic locking function is tested after any shop repair prior to EASA
Form 1 issuance.
consequen This Aot is only applicable to Mz-type ssc(s) already installed on  in-service aircraft at the time of issuance of this AOT
- Aircraft which are not fitted with any MZ-type SSC are not affected
by this AOT
The application of this AOT requires:
- Five man-hours and one hour elapsed time for the application of the
Page 3

### Page 4 (OCR)

ref.7 AMM task
- Additional three man-hours per SSC replacement.
4.2. DESCRIPTION
4.2.1. IDENTIFICATION/TEST OF AFFECTED AIRCRAFT
within 90 days from receipt of this AOT:
1. Identify all aircraft fitted with at least one MZ-type SC. Note that:
- pN Mz 4339390-12 is installed in positions 1 onlY.
- PN MZ 4306000-12 is installed in positions 2 to 6.
The two following procedures are approved for the identification:
- Use the data from operator approved records.
- Read the data by visual inspection on aircraft.
on aircraft which are not fitted with any Mz-type ssc, no further action
is required by this AOT.
L.At each position fitted with a MZ-type SSC, pertorm the test of the
hydraulic  locking function as per ref.7 AMM.
4.2.2 CORRECTIVE ACTIONS
1.On Blue hydraulic circuit, tor MZ-type SSC in position 2 and 3 (14CSI,
14CS2, 15CS1, 15CS2) :
- If the test is successful: No further action is required
- If the test fails: BEFORE FURTHER FLIGHT,  interchange with a
successfully tested unit from another circuit or replace with a spare
part the faulty SSC(s), as per ref.8 AMM.
2.on Green hydraulic circuit, for Mz-type SSC in position 1 and 5 (13Cs1,
13CS2, 17CS1, 17CS2) :
- If the test is successful: No further action is required
- If the test fails, or if an unsuccessfully tested sSC is installed in
position 5 after interchange with Blue circuit: within 24 months from
AOT receipt, replace the faulty SSC(s) with a spare part as per ref.8
or ref.9 AMM.
3.on Yellow hydraulic circuit, for MZ-type SSC in position 4 and 6 (16CS1,
16CS2, 18CS1, 18CS2) :
- If the test is successful: No further action is required
- If the test fails,  or if an  unsuccessfully tested ssc is installed
after interchange with Blue circuit:
replace the faulty ssC(s) with
and ref. 11 MMEL.
* Once all the faulty MZ-type SSC(s) are removed from the Yellow
hydraulic circuit:
Page 4

### Page 5 (OCR)

- Dispatch capability with the Y EMP inoperative is restored
as per ret.10 and ret.11 MMEL
- Report the retrofit completion as per paragraph 4.2.3
CAUTION: In order to prevent the installation of faulty units on non-
affected aircraft, only the interchange between positions of the same
aircraft is acceptable.
ADVICE: Due to spare restriction (refer to 4.3):
- It is acceptable to interchange with a unit successfully tested from
nother circuit of the same airplane,  or to replace with a spare part
che faulty SSC(s) identified in positions 2 and 3 (14CS1, 14CS2, 15CS1,
15CS2) .
acceptable to install or to keep installed unsuccessfully tested
SC(s) in positioN 24339390-12 without hydraulic locking capability  This approach allows:
per aircraft.
* up to six sSCs PN MZ4306000-12 without hydraulic locking capability
per aircraft.
4.2.3 DATA REPORTING
For all aircraft fitted with at least one M-type ssC, within 30 days after
accomplishment of the test as per paragraph 4.2.1, report the test results
to the Airbus contact given in paragraph 7 by means of the Reporting sheet
Step 2
all aircraft fitted with at least one unsuccessfully tested ssc on the
Yellow hydraulic  Sc(s) of the Yellow circuit as per paragraph 4.2.4'7 by means of Reporting  circuit, within 30 days after replacement of the faulty
report the retrofit
completion to the Airbus contact given in paragraph
Sheet ref. 12.
4.3. MATERIAL - TOOLING
No specific tooling is required for the inspection:
Concerning  Liebherr-Aerospace is currently facing a difficult
supply chain situation on SSC PN 1386x and 1387x -current production
standard- due to the  fire damage suffered by Liebherr-Aerospace
manufacturing plant in Brazil (ref.13).
Airbus and Liebherr-Aerospace will increase the spares stock, planned to
reach 60 units by June 2012. Nevertheless, the current number of available
spares remains insufficient to provide advanced spare parts to all
operators prior to application of this AOT.
ConsequentlY'+han six SScs PN MZ4306000-12 are found  spare units will be supplied on AOG basis to operators if and
only if more  faulty on the same
aircraft and no spares are available at the operator's warehouse.
Spare units have been positioned in Singapore,  Europe and the USA in order
to reduce the delivery lead-time. AOG orders should be addressed to:
Region: Europe, Africa, Middle East
Llebherr-Aerospace Lindenberg GmbH (LLI)
Phone: +49 8381 46 4868
Page 5

### Page 6 (OCR)

e-mail: spares.lli@liebherr.com
24 Hrs/7 Days Spares AOG Hotline: +49 171 852 7304
Region: Americas
Liebherr-Aerospace Saline, Inc (LSL)
Phone: +1 734 944 6378
e-mail: keith.turczyn@liebherr.com
24 Hrs/7 Days Spares AOG Hotline: +1 313 580 7262
Region: Asia-Pacific
Liebherr-Aerospace Singapore Pte. Ltd. (LSI)
Phone: +65 6265 2305
e-mail: charles.loke@liebherr.com
24 Hrs/7 Days Spares AOG Hotline: +65 9625 1607
According to the feedback as per paragraph 4.2.3,  Airbus and Liebherr-
Aerospace will establish a replacement plan of the faulty SSCs fitted on
Green and Yellow hydraulic circuits.
The hurt the tu car and time of the faulty cs) in shop repair.  loan units will be used to cover the spare
Process will  be monitored by Airbus and planned in accordance with
operators' situation and availability.
5. FURTHER ACTION
Follow-up of this AOT will be ensured by means of ref.14 TFU that will be
issued by the end of January, 2012.
6. AOT APPROVAL
The technical content of this AOT has been approved under EASA Design
Organization Approval EASA.21J.031.
The content of this AOT is expected to be rendered mandatory by the
Airworthiness Authorities.
7. REPORTING / ACKNOWLEDGEMENT
Operators are requested to acknowledge receipt of this AOT within 48 hours
after receipt to:
MIle Laetitia BONNET,  SEEL
Phone number: +33 (0)5 67 19 24 40
Fax number:  +33 (0)5 61 93 32 73
E-mail: laetitia.bonnet@airbus.com
This acknowledgement can be made through the Airbus RCSR office when
available.
Questions about the technical content of this AOT, and inspection results,
with or without findings,  are to be sent to Airbus Customer Services,
Engineering and Technical Support, attention of:
Mr. Daniel LOPEZ FERNANDEL'0? 04 52  SEEL6
Phone number: +33 (0)5 61
Fax number:  +33 (0) 5 61 93 32 73
E-mail:  daniel. lopez-fernandez@airbus.com
Page 6

### Page 7 (OCR)

Best Regards,
P. GOURDON
VICE PRESIDENT A330/A340 PROGRAMME
CUSTOMER SERVICES DIRECTORATE
organization ned to be added to the distribution, please advise your  or if other people in your
Airbus customer services contact accordingly.
AOT's attachments (if any) can be downloaded from Airbusworld via AirN@v /
Engineering.
Page 7

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.