# Airbus Alert Operators Transmission A35L007-14

## Copies (2)

Copies the FAA filed in AD dockets on regulations.gov, newest revision first. A newer revision may exist.

- Revision 01 ("Airbus"), 6 pages: PDF https://openairdocs.org/files/sha256/8d/4a/8d4a000f5d7c809078f0d0f255a98d7a08c4495af2bab3e12bab6baf6d002830; text https://openairdocs.org/service-documents/airbus/aot-a35l007-14/file/8d4a000f5d7c.md. Rights: © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2015-3149; AD 2016-03-07 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Revision 01 ("FAA-2015-3149_AOT_A35L007-14_-_Appendix_A_-_Generator_activation_template"), 1 page: PDF https://openairdocs.org/files/sha256/6a/25/6a257fa9ba8876f14477c1a5e26a452fde4e28b9fba72a724fc3c4c7232bb901; text https://openairdocs.org/service-documents/airbus/aot-a35l007-14/file/6a257fa9ba88.md. Rights: © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2015-3149; AD 2016-03-07 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Airbus](https://openairdocs.org/service-documents/airbus.md)
- Type: Other document (Alert Operators Transmission)
- Number: A35L007-14
- Latest revision known: A35L007-14, Revision 01, dated June 17, 2015 (OpenAirDocs)
- Page: https://openairdocs.org/service-documents/airbus/aot-a35l007-14

## ADs that cite it (1) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2016-03-07](https://openairdocs.org/ad/2016-03-07.md), effective Apr 13, 2016: Revision 01

Also cited in [1 proposed AD](https://openairdocs.org/service-documents/airbus/aot-a35l007-14/proposed.md).

## Text (6 pages)

Revision 01, the newest copy. Rights: © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2015-3149; AD 2016-03-07 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

CUSTOMER SERVICES DIRECTORATE 
1 ROND POINT MAURICE BELLONTE 
31707 BLAGNAC CEDEX FRANCE 
TELEPHONE + 33 (0)5 61 93 33 33 
 
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A35L007-14 Rev 01 Page 1 of 6 Date: 17-JUN-2015  
© AIRBUS S.A.S. 2014. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT 
 
 
SUBJECT: ATA  35 –  CHEMICAL OXYGEN GENERATORS EARLY REPLACEMENT 
  
 
AIRCRAFT TYPE:  A330,A340,A340-500,A340-600 
 
 
OUR REF.:  A35L007-14 Rev 01 dated 17-JUN-2015. 
 
OUR PREV. REF.:  A35L007-14 Rev 00 dated 18-DEC-2014  
 
 
0. REASON FOR REVISION 
 
Sampling and activation tests on oxygen generators manufactured between 1999 and 2004 have been 
performed since the publication of the revision 0 of this AOT. Several generators failed to activate during 
this sampling campaign. Hence, the revision of this AOT is considered to remove any generator older 
than 10 years since date of manufacture. 
The revised paragraphs are indicated between **BEG. REV** and **END REV**. 
 
1. AIRCRAFT AFFECTED 
 
**BEG. REV** 
All A330, A340, A340-500, A340-600 equipped with 15 & 22 minutes chemical oxygen generators older 
than 10 years since date of manufacture (PN 117042-xx). 
**END REV** 
 
Oxygen generators PN details: 
 
117042-02 (15 min – 2 masks) 
117042-03 (15 min – 3 masks)  
117042-04 (15 min – 4 masks) 
117042-22 (22 min – 2 masks) 
117042-23 (22 min – 3 masks) 
117042-24 (22 min – 4 masks) 
 
2. REFERENCED DOCUMENTATION 
 
**BEG. REV** 
EASA AD 2014-0277 (Revision 0 of this AOT was mandated by this AD) 
B/E Aerospace SIL D1019-01 
B/E Aerospace VSB 117042-35-001 
RIL LR35M14028324 Rev01 
**END REV** 
 
2.1 APPENDIX 
 
Appendix A: Emergency Oxygen Generators - Reporting sheet

### Page 2

ALERT OPERATORS TRANSMISSION - AOT
 
AOT ref: A35L007-14 Rev 01 Page 2 of 6 Date: 17-JUN-2015 
© AIRBUS S.A.S. 2014. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT 
 
2.2 REFERENCES 
 
**BEG. REV** 
Ref. 1: MPD tasks 352001-08-1 & 352142-01-1 - Discard chemical oxygen generators 
Ref. 2: MRBR task 35.20.01  - Discard chemical oxygen generators 
Ref. 3: AMM task 35-21-42-920-802-A - Discard CRR Chemical Oxygen Generators  
Ref. 4: AMM task 35-21-42-920-801-A - Discard Chemical Oxygen Generators 
Ref. 5: AMM task 35-21-44 PB 401 - container - emergency oxygen, chemical (crew rest) - 
removal/installation 
Ref. 6: AMM task 35-21-41 PB 401 - container - emergency oxygen, chemical - removal/installation 
**END REV** 
 
3. REASON 
 
**BEG. REV** 
This AOT is issued to inform the affected operators of identified and still investigated premature ageing 
of chemical oxygen generator PN 117042 -XX manufactured by B/E Aerospace. Some operators 
reported that some generators manufactured betwe en 1999 and 2004 failed to activate during 
maintenance activity. Based on initial analysis, all the generators older than 10 years since date of 
manufacture shall be removed from the field. 
 
 As required by MPD and MRBR tasks “Ref. 1 and Ref. 2”, the generators manufactured in 1999 
must be discarded before end of 2014. Therefore, this population is considered as being 
already covered by existing MPD/MRBR task and is not considered within this AOT. 
 The management of generators manufactured in 2000 and 2001 is described in the revision 0 of 
this AOT and is restated in § 3.3. 
 The management of generators manufactured after 2001 and older than 10 years since date of 
manufacture is described in this AOT revision 01 and is described in § 3.3. 
**END REV** 
 
3.1 FACTS 
 
**BEG. REV** 
The MPD and MRBR tasks “Ref. 1 and Ref. 2” require the replacement of chemical oxygen generators 
every 15 years.  
 
During this replacement, it is normally required to initiate the chemical reaction of the removed 
generators for proper dispos al. B/E Aerospace SIL D1019 -01 is the document which provides 
instructions for the activation and the disposal of a removed generator.  
 
On each chemical oxygen generator, there is an indicator which changes colour with heat, indicating 
that the reaction producing oxygen took place. Some operators reported that when they tried to activate 
generators manufactured between 1999 and 2004 after removal from the oxygen containers, some of 
them failed to activate. The affected generators PN are 117042 -XX (either 1 5 min or 22 min oxygen 
duration).   
**END REV** 
 
3.2 CONSEQUENCES 
 
**BEG. REV** 
Chemical generators older than 10 years since date of manufacture may fail to activate and may not 
deliver oxygen when needed.  
**END REV**

### Page 3

ALERT OPERATORS TRANSMISSION - AOT
 
AOT ref: A35L007-14 Rev 01 Page 3 of 6 Date: 17-JUN-2015 
© AIRBUS S.A.S. 2014. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT 
 
3.3 AIM 
 
Restatement of the requirements of AOT revision 0: 
 
 This AOT requires the replacement of all oxygen generators manufactured in 2000, in priority. 
Airbus assume that these generators are installed on Aircraft delivered the same year or early 
2001.  
 This AOT requires that the generators dated 2001 be replaced after generators dated 2000 are 
replaced. However, to limit operational disturbance, when inspecting an aircraft suspected to 
have generators dated 2000, it is requested to remove any generator dated 2001 that is found. 
 
**BEG. REV** 
New requirements of this AOT revision 01: 
 
 This AOT requires that the generators older than 10 years since date of manufacture be 
replaced. The compliance time is given in the paragraph 4.1.1 – Accomplishment timescale. 
 
For information, the ge nerator manufacturing date is written on the generator label and on the 
oxygen container test lever sticker.  
 
Note: Regarding spare parts, each Operator must ensure that any spare generator older than 10 
years since date of manufacture, which has been installed on Aircraft, is removed in the same time 
constraints as mentioned in paragraph 4.1.1.   
 
- For 15 min generators (PN 117042-0X), replacement generators PN E633X0-00 manufactured 
in Lübeck , Germany by B/E Aerospace will be delivered with a kit in order to adapt the 
generator inside the container. Instructions for this replacement are given in AMM tasks “Ref. 3, 
4, 5 and 6” and in the B/E Aerospace VSB 117042-35-001.  
 
- For 22 min generators (PN 117042-2X), fully interchangeable containers manufactured in 
Lübeck, Germany by B/E Aerospace will be delivered. Unlike the previous AOT version, 
replacement generators (same PN) manufactured in Lenexa cannot be ordered due to 
limited production capability. Instructions for this replacement are given in AMM task “Ref.5 
and 6”. 
 
If an operator has generators PN 117042-XX in stock, and less than 10 years old, they may be used 
as well. 
 
Note: The oxygen generator P/N 117042-XX is installed on the following containers:  
Type I container P/Ns: G1L/RXXX-XX; W1L/RXXX-XX; E1L/RXXX-XX  
Type II container P/Ns: G2F/NXXX-XX; E2F/NXXX-XX  
Type III container P/Ns: G3NXXX-XX; W3NXXX-XX; E3NXXX-XX   
In addition, the oxygen generator PN 117042-XX can also be fitted on containers A1, AA, AB, AH, AJ-
series (initially fitted with generator PN 117019-XX) and on containers AE, AF-series (initially fitted with 
generator PN 117028-XX). If a generator PN 117042-XX is found installed on one of these container 
series, new generators PN 117019-XX and PN 117028-XX can be delivered by B/E Aerospace. 
 
Airbus highly recommend Operators not to wait until the due date before ordering the new generators. 
This recommendation is especially valid when ordering full containers due to the longer manufacturing 
time. 
**END REV** 
 
After their replacement, this AOT requires to activate all the removed generators (as per instructions of 
vendor SIL D1019-01) and requires to record for each generator the PN, the date of manufacture, the lot

### Page 4

ALERT OPERATORS TRANSMISSION - AOT
 
AOT ref: A35L007-14 Rev 01 Page 4 of 6 Date: 17-JUN-2015 
© AIRBUS S.A.S. 2014. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT 
 
code and whether or not the chemical reaction worked properly. The template to report the activation 
results is provided in the appendix A of this AOT. This feedback from the operators is necessary for 
supporting the on-going investigation, it will allow to determine the extent of this issue and it will help to 
define if further actions for continued airworthiness are necessary. 
 
Please refer to paragraph “7. REPORTING” to submit your feedback. 
 
 
4. SHORT TERM ACTION 
 
4.1 PLANNING AND MANPOWER 
 
4.1.1 ACCOMPLISHMENT TIMESCALE 
 
Replacement of all oxygen generators PN 117042-XX manufactured in 2000 must be done as far as 
possible in advance of the MPD/MRBR requirements and in any case not later than June 2015, 
whichever occurs first. 
 
Replacement of all oxygen generators PN 117042 -XX manufactured in 2001 m ust be done as far as 
possible in advance of the MPD/MRBR requirements and in any case not later than December 2015 
whichever occurs first. 
**BEG. REV** 
New requirements of this AOT revision 01: 
Replacement of all oxygen generators PN 117042-XX must be done before exceeding 10 years since 
date of manufacture or within the compliance time specified in Table 1, whichever occurs later.  
Table 1 - Replacement of Passenger Oxygen Generators 
Year of manufacture 
Compliance Time 
(starting from the publication date of 
this AOT) 
2002 Within 12 months 
2003 Within 16 months 
2004 Within 20 months 
2005 Within 24 months 
2006 Within 28 months 
2007 Within 32 months 
2008 Within 36 months 
 
For generators manufactured after 2008, they will have to be replaced before being older than 10 years 
since date of manufacture. 
**END REV**

### Page 5

ALERT OPERATORS TRANSMISSION - AOT
 
AOT ref: A35L007-14 Rev 01 Page 5 of 6 Date: 17-JUN-2015 
© AIRBUS S.A.S. 2014. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT 
 
4.2 DESCRIPTION 
 
For 15 min generators (PN 117042-0X), please refer to AMM tasks “Ref. 3, 4, 5 and 6” and to B/E 
Aerospace VSB 117042-35-001 providing instructions for disassembly, assembly and testing.  
 
**BEG. REV** 
For 22 min generators (PN 117042-2X), please refer to the AMM task “Ref. 5 and 6”. 
 
If an operator has generators PN 117042 -XX in stock, and less than 10 years old, they may be used 
as well. 
 
This AOT is the subject of an A IRBUS monitored retrofit campaign, which will be detailed in a Retrofit 
Information Letter (RIL LR35M14028324 Rev01). 
**END REV**  
For the organisation of this retrofit, you are kindly requested to contact AIRBUS retrofit management 
department: 
 
AIRBUS CUSTOMER SERVICES DIRECTORATE 
1 Rond-Point Maurice Bellonte 
31707 BLAGNAC CEDEX 
France 
Tel: (33) 5 67 19 06 22 
E-mail: monitored.retrofit@airbus.com 
Fax: (33) 5 61 93 27 45 
 
5. FURTHER INFORMATION 
 
5.1 FOLLOW-UP PLAN 
 
**BEG. REV** 
Airbus have currently not received any failure report on generators less than 10 years old. However, in 
order to investigate further this potential premature ageing, a sampling test on these generators will be 
performed. The results of this sampling will allow Airbus and B/E Aerospace to adjust the retrofit and the 
sampling actions on these units if necessary. 
**END REV** 
 
5.2 IMPACTED DOCUMENTATION 
 
As explained in paragraph 3.3, the 15 min replacement generators will be delivered with a kit in order to 
adapt the new generator inside the container as described in VSB 117042-35-001. This adaptation 
leads to a container PN change. The post-MOD container is two way interchangeable with the pre-MOD 
one. The IPC will be updated accordingly. 
 
6. AOT APPROVAL 
 
The technical content of this document is approved under the authority of DOA nr. EASA.21J.031.  
It is anticipated that this AOT will be mandated by the issuance of an EASA Airworthiness Directive.

### Page 6

ALERT OPERATORS TRANSMISSION - AOT
 
AOT ref: A35L007-14 Rev 01 Page 6 of 6 Date: 17-JUN-2015 
© AIRBUS S.A.S. 2014. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT 
 
7. REPORTING 
**BEG. REV** 
The results of generator activation and questions about this AOT are to be sent to Airbus Customer 
Services engineering as soon as possible, after the AOT application, through TechRequest on Airbus 
World, selecting Engineering Domain and ATA 35-20. 
**END REV** 
 
 
Best Regards, 
 
 
Jean-Luc MOUYSSET 
VICE PRESIDENT ENGINEERING SUPPORT 
CUSTOMER SERVICES 
Sabine KLAUKE  
VICE PRESIDENT A330/A340 PROGRAMME 
CUSTOMER SERVICES

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.