# Airbus All Operators Transmission A35N006-14

## Copies (2)

Copies the FAA filed in AD dockets on regulations.gov, newest revision first. A newer revision may exist.

- No revision named ("AOT-A35N006-14"), 4 pages: PDF https://openairdocs.org/files/sha256/19/f0/19f0bd4098efd7dddeb7aca696206fadb45bb14df1232d97ac0483f2ddf1b70f; text https://openairdocs.org/service-documents/airbus/aot-a35n006-14/file/19f0bd4098ef.md. Rights: © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2015-3989; AD 2016-16-02 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- No revision named ("AOT-A35N006-14-Appendix1"), 1 page: PDF https://openairdocs.org/files/sha256/1d/5f/1d5f3c82ffdc82ff5837fdca17531504294929fdf52235df702103d7f4a73e4b; text https://openairdocs.org/service-documents/airbus/aot-a35n006-14/file/1d5f3c82ffdc.md. Rights: © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2015-3989; AD 2016-16-02 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Airbus](https://openairdocs.org/service-documents/airbus.md)
- Type: Other document (All Operators Transmission)
- Number: A35N006-14
- Page: https://openairdocs.org/service-documents/airbus/aot-a35n006-14

## ADs that cite it (2) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2016-16-02](https://openairdocs.org/ad/2016-16-02.md), effective Sep 16, 2016: No revision named
- [AD 2016-10-13](https://openairdocs.org/ad/2016-10-13.md), effective Jun 30, 2016: No revision named

Also cited in [2 proposed ADs](https://openairdocs.org/service-documents/airbus/aot-a35n006-14/proposed.md).

## Text (4 pages)

No revision named, the newest copy. Rights: © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2015-3989; AD 2016-16-02 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

CUSTOMER SERVICES DIRECTORATE 
1 ROND POINT MAURICE BELLONTE 
31707 BLAGNAC CEDEX FRANCE 
TELEPHONE + 33 (0)5 61 93 33 33 
 
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A35N006-14 Rev 00 Page 1 of 4 Date: 10-DEC-2014  
© AIRBUS S.A.S. 2014. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT 
 
 
SUBJECT: ATA  35 – CHEMICAL OXYGEN GENERATORS EARLY REPLACEMENT 
 
 
AIRCRAFT TYPE:  A318,A319,A320,A321 
 
 
OUR REF.:  A35N006-14 Rev 00 dated 10-DEC-2014. 
 
 
1. AIRCRAFT AFFECTED 
 
All A318, A319, A320, A321 equipped with 15 & 22 minutes chemical oxygen generators PN 117042-XX 
manufactured in 2000 and 2001 by B/E Aerospace. 
 
Oxygen generators PN details: 
117042-02 (15 min – 2 masks) 
117042-03 (15 min – 3 masks)  
117042-04 (15 min – 4 masks) 
117042-22 (22 min – 2 masks) 
117042-23 (22 min – 3 masks) 
117042-24 (22 min – 4 masks) 
 
 
2. REFERENCED DOCUMENTATION 
 
B/E Aerospace SIL D1019-01 
B/E Aerospace VSB 117042-35-001 
 
2.1 APPENDIX 
 
Appendix A: Generator activation template 
 
2.2 REFERENCES 
 
Ref 1: MPD task 352142-01-1 - Discard chemical oxygen generators 
Ref 2: AMM task 35-21-00-920-001-A - Discard oxygen generators 
Ref 3: AMM task 35-21-41 PB 401 - Container - emergency oxygen - removal/installation 
 
 
3. REASON 
 
This AOT is issued to inform the affected operators of identified and still under investigation premature 
ageing on chemical oxygen generator PN 117042-XX manufactured by B/E Aerospace. Some operators 
reported that some generators manufactured in 1999, 2000 and 2001 failed to activate. Given the 
number of failed units reported, all the generators dated 1999, 2000 and 2001 shall be removed from 
the field. 
 
 As required by MPD task  “Ref 1”, the generators manufactured in 1999 must be discarded 
before end of 2014.  Therefore, this population is considered as being already covered by 
existing MPD task and is not considered within this AOT. 
 The management of generators manufactured in 2000 and 2001 is described in § 3.3.

### Page 2

ALERT OPERATORS TRANSMISSION - AOT
 
AOT ref: A35N006-14 Rev 00 Page 2 of 4 Date: 10-DEC-2014  
© AIRBUS S.A.S. 2014. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT 
 
 
3.1 FACTS 
 
The MPD task “Ref 1” requires the replacement of chemical oxygen generators every 15 years.  
 
During this replacement, it is normally required to initiate the chemical reaction of the removed 
generators for proper disposal. B/E Aerospace SIL D1019-01 is the document which provides 
instructions for the activation and the disposal of a removed generator.  
 
On each chemical oxygen generato r, there is an indicator which changes colo ur with heat, indicating 
that the reaction producing oxygen took place. Some operators reported that when they tried to activate 
generators manufactured in 1999, 2000 and 2001 after removal from the oxygen contain ers, some of 
them failed to activate. The affected generators PN are 117042 -XX (either 15 min or 22 min oxygen 
duration). 
 
3.2 CONSEQUENCES 
 
Chemical generators manufactured in 1999, 2000 and 2001 may fail to activate and may not deliver 
oxygen.  
 
3.3 AIM 
 
 This AOT requires the replacement of all oxygen generators manufactured in 2000, in priority. 
Airbus assume that these generators are installed on Aircraft delivered the same year or early 
2001. 
 This AOT requires that the generators dated 2001 be replaced after generators dated 2000 are 
replaced. However, to limit operational disturbance, when inspecting an aircraft suspected to 
have generators dated 2000, it is requested to remove any generator dated 2001 that is found. 
 
For information, the generator manufacturing date is written on the generator label and on the 
oxygen container test lever sticker. 
 
Note: based on feedback on operators practices, spare parts manufactured in 2000 & 2001 may 
have only been fitted on aircraft manufactured in 1988 or before. Nevertheless, operators must 
ensure that any spare generator dated 2000 or 2001, potentially fitted on their fleet, is removed in 
the same time constraints as mentioned in paragraph 4.1.1. 
 
- For 1 5 min generators (PN 117042-0X), replacement generators manufactured in Lübeck, 
Germany by B/E Aerospace will be delivered with a kit in order to adapt the generator inside the 
container. Instructions for this replacement are given in  the AMM task “Ref 3” and in the B/E 
Aerospace VSB 117042-35-001. 
 
- For 22 min generators (PN 117042 -2X), fully interchangeable container s manufactured in 
Lübeck, Germany by B/E Aerospace will be delivered. Alternatively, r eplacement generators 
manufactured in Lenexa, US can also be ordered. They will fit directly in the current 
containers and will not need any adaptation such as the 15 min ones. The 22 min genera tor 
PN remains the same. Instructions for this replacement are given in the AMM task “Ref 2 and 
3”. 
 
If an operator has generators PN 117042 -XX in stock, and manufactured after 2001, they may be 
used as well.

### Page 3

ALERT OPERATORS TRANSMISSION - AOT
 
AOT ref: A35N006-14 Rev 00 Page 3 of 4 Date: 10-DEC-2014  
© AIRBUS S.A.S. 2014. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT 
 
 
After the replacement, this AOT requires to activate all the removed generators (as per instructions on 
SIL D1019-01) and requires to record for each generator the PN, the date of manufacture, the lot code 
and whether or not the chemical reaction worked properly. The template to record the activation results 
is provided in the appendix A of this AOT. This feedback from the operators is necessary for supporting 
the on-going investigation, will allow to determine the extent of this issue and will help to define further 
continued airworthiness actions. 
 
Please refer to paragraph “7. REPORTING” to submit your feedback. 
 
 
4. SHORT TERM ACTION 
 
4.1 PLANNING AND MANPOWER 
 
4.1.1 ACCOMPLISHMENT TIMESCALE 
 
Replacement of all oxygen generators PN 117042 -XX manufactured in 2000 must be done  as far as 
possible in advance of the MPD requirements and in any case not later than Jun e 2015, whichever 
occurs first. 
 
Replacement of all oxygen generators PN 117042 -XX manufactured in 2001 must be done as far as 
possible in advance of the MPD requirements and in any case not later than December 2015 whichever 
occurs first. 
 
4.2 DESCRIPTION 
 
For 15 min generators (PN 117042-0X), please refer to  AMM task “Ref 3” and  B/E Aerospace VSB 
117042-35-001 providing instructions for disassembly, assembly and testing.  
For 22 min generators (PN 117042-2X), please refer to the AMM task “Ref 2 and 3”. 
 
If an ope rator has generators PN 117042 -XX in stock, and manufactured after 2001, they may be 
used as well. 
 
This AOT is the subject of an AIRBUS monitored retrof it campaign, which will be detailed in a Retrofit 
Information Letter (RIL).  
For the organisation of this retrofit, you are kindly requested to contact AIRBUS retrofit management 
department: 
AIRBUS CUSTOMER SERVICES DIRECTORATE 
1 Rond-Point Maurice Bellonte 
31707 BLAGNAC CEDEX 
France 
Tel: (33) 5 67 19 06 22 
E-mail: monitored.retrofit@airbus.com 
Fax: (33) 5 61 93 27 45

### Page 4

ALERT OPERATORS TRANSMISSION - AOT
 
AOT ref: A35N006-14 Rev 00 Page 4 of 4 Date: 10-DEC-2014  
© AIRBUS S.A.S. 2014. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT 
 
 
5. FURTHER INFORMATION 
 
5.1 FOLLOW-UP PLAN 
 
Airbus have currently not received any failure report on generators manufactured in 2002 and after. 
However, in order to investigate further this potential premature ageing, a sampling test on generators 
manufactured in 2002 and 2003 will be performed. The results of this sampling will allow Airbus and B/E 
Aerospace to adjust the retrofit and the sampling actions on these units if necessary. 
 
5.2 IMPACTED DOCUMENTATION 
 
As explained in paragraph 3.3, the 15 min replacement generators will be delivered with a kit in order to 
adapt the new generator inside the container as described in VSB 117042-35-001. This adaptation will 
lead to a container PN change. The post-MOD container is two way interchangeable with the pre-MOD 
one. The IPC will be updated accordingly. 
 
 
6. AOT APPROVAL 
 
The technical content of this document is approved under the authority of DOA nr. EASA.21J.031.  
 
 
7. REPORTING 
The results of generator activation and questions about this AOT and are to be sent to Airbus Customer 
Services engineering as soon as possible, after the AOT application, to the attention of: 
 
Florent FARBOS 
Engineer 
Emergency & Cabin Systems, Galleys & Lav’s  
Customer Services Engineering - SEEC2 
Phone: +33 (0)5 82 05 51 06 
Fax: +33 (0)5 61 93 44 25 
Mailto:florent.farbos@airbus.com 
AIRBUS S.A.S. 
1 rond-point Maurice Bellonte 
31707 Blagnac Cedex 
France 
 
Best Regards, 
 
 
Jean-Luc MOUYSSET 
VICE PRESIDENT ENGINEERING SUPPORT 
CUSTOMER SERVICES 
Gilles DE CEVINS 
VICE PRESIDENT A320 PROGRAMME 
CUSTOMER SERVICES

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.