Copy: No revision named ("A35N020-23 Rev 00"), 6 pages: PDF https://openairdocs.org/files/sha256/4c/bb/4cbbd328d419af5a659b16e477a2deb6350bddeb031d6c16531a7c44626e84b1; text https://openairdocs.org/service-documents/airbus/aot-a35n020-23/file/4cbbd328d419.md. Rights: © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2024-0471, the docket of AD 2024-26-05. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Airbus](https://openairdocs.org/service-documents/airbus.md)
- Type: Other document (All Operators Transmission)
- Number: A35N020-23
- Page: https://openairdocs.org/service-documents/airbus/aot-a35n020-23

## ADs that cite it (1) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2024-26-05](https://openairdocs.org/ad/2024-26-05.md), effective Mar 11, 2025: No revision named

## Text (6 pages)

Rights: © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2024-0471, the docket of AD 2024-26-05. Not covered by OpenAirDocs’ CC0 dedication. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

CUSTOMER SERVICES DIRECTORATE
2 ROND POINT EMILE DEWOITINE
31700 BLAGNAC FRANCE
TELEPHONE + 33 (0)5 61 93 33 33
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A35N020-23 Rev 00 Page 1 of 6 Date: 10-OCT-2023
C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2023. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
SUBJECT: ATA 35 – Chemical oxygen generator replacement
AIRCRAFT TYPE: A318, A319, A320, A321
OUR REF.: A35N020-23 Rev 00 dated 10-OCT-2023
EFFECTIVITY DATE: 10-OCT-2023 
1. AIRCRAFT AFFECTED
All A320 Family aircraft, equipped with 15 minutes or 22 minutes Chemical oxygen containers having Part 
Numbers and Serial Numbers as provided in Reference 1.
2. REFERENCED DOCUMENTATION
2.1 APPENDIX
N/A
2.2 REFERENCES
Reference 1: COLLINS Aerospace SB Ref: XXCXX-35-001 dated 06-OCT-2023 or later revision if 
applicable.
Reference 2: A318/A319/A320/A321 AMM TASK 35-21-42-000-001-A -“Removal of the Emergency 
Oxygen Generators”.
Reference 3: A318/A319/A320/A321 AMM TASK 35-21-42-400-001-A -“Installation of the Emergency 
Oxygen Generators”.
Reference 4: A318/A319/A320/A321 AMM TASK 35-21-41-000-001-A - “Removal of the Emergency 
Oxygen Containers”.
Reference 5: A318/A319/A320/A321 AMM TASK 35-21-41-400-001-A - “Installation of the Emergency 
Oxygen Containers”.
Reference 6: Airbus Retrofit Information Letter (RIL) Ref. X35M23001621 dated 10-OCT-2023 or later 
revision if applicable (associated to TFU 35.21.00014).
Reference 7: Airbus In-Service Information (ISI) article Ref. 35.21.00015
3. REASON
The purpose of this AOT is to advise A320 Family operators of a potential quality escape on a 
component in a limited number of chemical oxygen generators and to request the replacement of the 
affected oxygen generators installed on aircraft and in airline spare stock.
3.1 FACTS

### Page 2

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A35N020-23 Rev 00 Page 2 of 6 Date: 10-OCT-2023
C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2023. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
Airbus informs the operators that a quality escape on Chemical oxygen generators was identified 
recently on a limited number of units manufactured in 2010 having PN E63320-00, PN E63340-00 and 
PN E63440-00 which could lead to no oxygen delivery from the affected units.
For the list of affected oxygen container Part Numbers (NHA) please refer to Reference 1.
3.2 HISTORY/BACKGROUND
Several instances of chemical oxygen generators failing to activate have been reported in service or 
during maintenance activity.
3.3 ROOT CAUSE
The root cause is due to poor reactivity of the start powder used inside the oxygen generator.
After pulling the mask lanyard, the pin release allows the spring-loaded firing pin to hit the primer cap. The 
primer cap ignites the start powder which in turn ignites the ignition plate and then the chlorate core (for 
oxygen production).
In case the start powder is not reactive enough the ignition chain is stopped and oxygen is not produced 
by the chemical generator.
3.4 INVESTIGATION
Root cause investigation is still ongoing in order to explain why some batches of start powder produced 
in 2010 have shown this low reaction.
There is no test or procedure which can identify a generator with non-reactive start powder, it is only 
identifiable at oxygen generator activation. This failure is considered as a dormant failure potentially 
affecting a batch of 1063 generators having PN E63320-00, PN E63340-00 and PN E63440-00. These 
generators have been installed in a total number of 1055 containers produced in 2010 and mainly used 
on A320 Family aircraft but also on A330/A340 aircraft and only sold as spare containers for A310/A300-
600/AST aircraft.
The generators/containers targeted by this AOT consist in a first batch, which may be complemented 
later on, when the root cause affecting the start powder is fully identified.
3.5 CONSEQUENCES
There is a risk of no oxygen supply on all masks of affected containers in case of activation during a 
cabin decompression event.
4. OBJECTIVES OF THIS AOT
This AOT requires the replacement and return to the manufacturer COLLINS Aerospace - as described 
in Reference 1 - of all potentially affected oxygen generators installed on aircraft or part of spare stock.
5. MAINTENANCE PROCEDURE

### Page 3

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A35N020-23 Rev 00 Page 3 of 6 Date: 10-OCT-2023
C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2023. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
Oxygen generators to be removed and replaced are installed inside the oxygen containers with Part 
Numbers and Serial Numbers as listed in the Reference 1, and in each of the following situations:
-Oxygen container is installed on aircraft.
-Oxygen container is in airline spare stock.
NOTE: This AOT is classified mandatory or expected to be classified mandatory by an Airworthiness 
Directive (AD). If the instructions of this AOT are marked as Required for Compliance (RC), the 
operator must follow the instructions as indicated. These instructions are introduced by “in 
accordance with”.
NOTE: The instructions of this AOT include procedures given in other documents or in other sections 
of the AOT. If the instructions of this AOT are NOT marked as Required for Compliance (RC), the 
operator can use an alternative procedure accepted by his/her local authority. These instructions 
are introduced by “refer to”.
NOTE: When this AOT gives the access or close-up instructions with no return to service tests, the 
operator can adapt these instructions to add flexibility to the maintenance operations. The technical 
intent of this AOT must comply with the set parameters.
5.1 PLANNING – (RC)
Perform the removal and replacement of all potentially affected oxygen generators in accordance with 
document Reference 1 at next convenient opportunity, but no later than 3 months from AOT effectivity 
date.
While this AOT also requires to return the affected oxygen generators removed from aircraft or from 
stock to COLLINS Aerospace in accordance with Reference 1 and Reference 6, this action does not 
fall inside the 3 months effectivity date of this AOT, but should still be performed at the earliest 
convenience in order to support COLLINS Aerospace investigation.
5.2 MANPOWER
The estimated time to perform this replacement is 1.5 MH per oxygen container (0.5 for Removal + 0.25 
for generator replacement + 0.75 for Installation).
5.3 ACCESS
For oxygen generators installed on aircraft, several locations may exist (cabin, lavatory, galley, door area, 
other areas). Therefore, it is required to obtain information about access for each cabin configuration and 
for each different location/FIN as detailed inside maintenance task Reference 4.
5.4 INSPECTION – (RC)
To perform this AOT the operators are required to identify the potentially affected oxygen 
containers/generators in accordance with Reference 1:
-using applicable maintenance records,
AND/OR
-by visual inspection of the oxygen container/generator installed on aircraft*,
AND/OR
-using spare stock listing/records,

### Page 4

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A35N020-23 Rev 00 Page 4 of 6 Date: 10-OCT-2023
C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2023. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
AND/OR
-by direct visual inspection of existing spare stock.
*Note: As further detailed in the document Reference 1 it is possible, on wing, to quickly see if the 
generator Date of Manufacturing is - or is not - 2010 by reading the sticker which is easily accessible 
on each container door Test Button.
5.5 FINDINGS – (RC)
The identified affected oxygen generators must be removed and replaced - at aircraft level or in shop - by 
unaffected parts and must be removed from stock.
Further detail on this is provided by the document Reference 1.
5.6 INSTRUCTIONS – (RC)
Remove/Install the affected oxygen container installed on aircraft in accordance with Reference 4 and 
Reference 5. 
Remove and replace the affected oxygen generator installed inside the container in accordance with 
Reference 1, Reference 2 and Reference 3. 
Once replaced by an unaffected oxygen generator with same PN in accordance with Reference 1, 
report to Airbus (refer to paragraph 8. of this AOT) and return the affected oxygen generators removed 
from aircraft or from stock to COLLINS Aerospace in accordance with Reference 1 and Reference 6.
DO NOT activate the generator (it must be shipped not activated, but secured with safety pin, for the 
purpose of the investigation).
The operators shall later ensure that any oxygen generator installed on aircraft is not part of the affected 
batch as shown in the document Reference 1.
5.7 SPARES AND TOOLING
Removal/Installation of the oxygen container installed on aircraft - refer to Reference 4 and Reference 
5 - may require:
-CAP – BLANKING (No specific)
-ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20 (No specific)
-PIN – REALEASE (No specific)
-SAFETY CLIP - CIRCUIT BREAKER (No specific)
-STEPLADDER 1.0 M (3.3 FT) (No specific)
-WARNING NOTICE(S) (No specific)
-98A25207503000 PULLEY ASSEMBLY - SEALING CORD or equivalent
-995000-00 TOOL-MANUAL RELEASE (or 995000 or E60100-00 or equivalent)
Replacement of the oxygen generator installed inside the oxygen container - refer to Reference 1, 
Reference 2 and Reference 3 - may require:
-GLOVES - COTTON, LINT-FREE, CLEAN (No specific)
-SAFETY CLIP - CIRCUIT BREAKER (No specific)
-WARNING NOTICE(S) (No specific)
-PLIERS – END-CUTTING (No specific)
-PLIERS 178 MM (7 IN.) - GRIP (No specific)
-995000-00 TOOL-MANUAL RELEASE (or 995000 or E60100-00 or equivalent)
-995022 INSERTION TOOL-PIN, OXYGEN GENERATOR

### Page 5

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A35N020-23 Rev 00 Page 5 of 6 Date: 10-OCT-2023
C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2023. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
-Torque wrench: range to between 0.034 and 0.12 m.daN (3.01 and 10.62 lbf.in) (No specific)
-Torque wrench: range to between 0.034 and 0.045 m.daN (3.01 and 3.98 lbf.in) (No specific)
-Torque wrench: range to between 0.09 and 0.11 m.daN (7.96 and 9.73 lbf.in) (No specific)
-Torque wrench: range to between 0.1 and 0.12 m.daN (8.85 and 10.62 lbf.in) (No specific)
-PLIERS E71516-00 (from B/E Aerospace as per Reference 1)
The oxygen generator with the same Part Number has to be ordered from COLLINS Aerospace in 
accordance with Reference 1 and Reference 6.
Additionally, when replacing the oxygen generator, it may be found that the oxygen masks do not meet 
CMM criteria and need replacement. Because of this we may recommend that a sufficient quantity of 
oxygen masks be ordered in advance to secure the containers retrofit. Due to differences in masks 
models and characteristics (interchangeabilities, hose and lanyard length, pull flag) the correct mask 
Part Numbers for each container configuration shall be obtained in the applicable CMM from COLLINS 
Aerospace.
6. ADDITIONAL INFORMATION
6.1 FOLLOW-UP PLAN
In case of additional findings, the Reference 1 list of PN and SN may be updated, for that reason, 
operators may want to keep their records for later when they initially check for aircraft configuration in 
the frame of this AOT.
Additional information about this AOT is available in Reference 7.
6.2 IMPACTED DOCUMENTATION
N/A
7. AOT APPROVAL
The technical content of this document is approved under the authority of the DOA ref. EASA.21J.031.
8. REPORTING
Address your inspection results (with or without findings) to Airbus Customer Services through the generic 
e-mail address. Refer to the latest reporting policy (Ref in the OIT 999.0018/16). 
Give the AOT reference in the mail title, as follows: {A35N020-23} Inspection Result
You can address your questions about this AOT to Airbus Customer Services through TechRequest 
on Airbus World, selecting Engineering Domain, Engineering Support Section and ATA 35-20/Topic 
Chemical oxygen generator replacement.
Best Regards,
Ahmed CHABBOUH
IN-SERVICE ENGINEERING SENIOR 
DIRECTOR 
Jean-Pierre GOMEZ
VICE PRESIDENT A320 PROGRAMME
CUSTOMER SERVICES

### Page 6

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A35N020-23 Rev 00 Page 6 of 6 Date: 10-OCT-2023
C80_AOT_FM1104649_v8.0 © AIRBUS S.A.S. 2023. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
CUSTOMER CARE CENTRE

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.