# Airbus All Operators Transmission A35W008-14

Copy: No revision named ("FAA-2015-7528_AOT A35W008-14 w appendix A"), 5 pages: PDF https://openairdocs.org/files/sha256/48/d4/48d4b9baf54e693fac892297f875a7b985b00267d1352a94101560098b51995e; text https://openairdocs.org/service-documents/airbus/aot-a35w008-14/file/48d4b9baf54e.md. Rights: © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2015-7528; AD 2016-10-13 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Airbus](https://openairdocs.org/service-documents/airbus.md)
- Type: Other document (All Operators Transmission)
- Number: A35W008-14
- Page: https://openairdocs.org/service-documents/airbus/aot-a35w008-14

## ADs that cite it (1) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2016-10-13](https://openairdocs.org/ad/2016-10-13.md), effective Jun 30, 2016: No revision named

Also cited in [1 proposed AD](https://openairdocs.org/service-documents/airbus/aot-a35w008-14/proposed.md).

## Text (5 pages)

Rights: © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2015-7528; AD 2016-10-13 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

CUSTOMER SERVICES DIRECTORATE
1 ROND POINT MAURICE BELLONTE
31707 BLAGNAC CEDEX FRANCE
TELEPHONE + 33 (0)5 61 93 33 33
ALERT OPERATORS TRANSMISSION - AOT
AOT ref: A35W008-14 Rev 00 Page 1 of 4 Date: 18-DEC-2014
© AIRBUS S.A.S. 2014. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
SUBJECT: ATA  35 –  CHEMICAL OXYGEN GENERATORS EARLY REPLACEMENT
AIRCRAFT TYPE:  A300-600, A310, AST 
OUR REF.:  A35W008-14 Rev 00 dated 18-DEC-2014
1. AIRCRAFT AFFECTED
All A300-600, A300-600-ST, A310 equipped with 15 & 22 minutes chemical oxygen generators PN 
117042-XX manufactured in 2000 and 2001 by B/E Aerospace.
Oxygen generators PN details:
117042-02 (15 min – 2 masks)
117042-03 (15 min – 3 masks) 
117042-04 (15 min – 4 masks)
117042-22 (22 min – 2 masks)
117042-23 (22 min – 3 masks)
117042-24 (22 min – 4 masks)
2. REFERENCED DOCUMENTATION
B/E Aerospace SIL D1019-01
B/E Aerospace VSB 117042-35-001
2.1 APPENDIX
Appendix A: Generator activation template
2.2 REFERENCES
Ref. 1: MPD task 352101-03-1 - Discard and replace chemical oxygen generator in lavatory (for A300-
600)
Ref. 2: MRD task 35.20.00/03 – Lavatory oxygen system – Discard generators (for A300-600-ST)
Ref. 3: MPD task 352113-01-1 - Discard chemical oxygen generators (for A300-600 and A310)
Ref. 4: AMM task 35-21-13 PB 401 – Emergency oxygen generators-Removal/Installation
Ref. 5: AMM task 35-21-11 PB 401 - Emergency oxygen container - Removal/Installation
3. REASON
This AOT is issued to inform the affected operators of identified and still under investigation premature 
ageing on chemical oxygen generator PN 117042-XX manufactured by B/E Aerospace. Some operators 
reported that some generators manufactured in 1999, 2000 and 2001 failed to activate. Given the 
number of failed units reported, all the generators dated 1999, 2000 and 2001 shall be removed from 
the field.
 As required by MPD and MRD tasks “Ref. 1 to 3”, the generators manufactured in 1999 must be 
discarded before end of 2014. Therefore, this population is considered as being already 
covered by existing MPD and MRD tasks and is not considered within this AOT.
 The management of generators manufactured in 2000 and 2001 is described in paragraph 3.3 
3.1 FACTS

### Page 2

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A35W008-14 Rev 00 Page 2 of 4 Date: 18-DEC-2014
© AIRBUS S.A.S. 2014. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
The MPD and MRD tasks “Ref. 1 to 3” require the replacement of chemical oxygen generators every 15 
years. 
During this replacement, it is normally required to initiate the chemical reaction of the removed 
generators for proper disposal. B/E Aerospace SIL D1019-01 is the document which provides 
instructions for the activation and the disposal of a removed generator. 
On each chemical oxygen generator, there is an indicator which changes colour with heat, indicating 
that the reaction producing oxygen took place. Some operators reported that when they tried to activate 
generators manufactured in 1999, 2000 and 2001 after removal from the oxygen containers, some of 
them failed to activate. The affected generators PN are 117042-XX (either 15 min or 22 min oxygen 
duration).  
3.2 CONSEQUENCES
Chemical generators manufactured in 1999, 2000 and 2001 may fail to activate and may not deliver 
oxygen when needed in abnormal and unusual operational circumstances. 
3.3 AIM
 This AOT requires the replacement of all oxygen generators manufactured in 2000, in priority. 
 This AOT requires that the generators dated 2001 be replaced after generators dated 2000 are 
replaced. However, to limit operational disturbance, when inspecting an aircraft suspected to 
have generators dated 2000, it is requested to remove any generator dated 2001 that is found.
For information, the generator manufacturing date is written on the generator label and on the 
oxygen container test lever sticker. 
Note: Based on feedback on operators practices, spare parts manufactured in 2000 & 2001 may 
have only been fitted on aircraft manufactured in 1988 or before. Nevertheless, operators must 
ensure that any spare generator dated 2000 or 2001, potentially fitted on their fleet, is removed in 
the same time constraints as mentioned in paragraph 4.1.1.  
- For 15 min generators (PN 117042-0X), replacement generators manufactured in Lübeck, 
Germany by B/E Aerospace will be delivered with a kit in order to adapt the generator inside the 
container. Instructions for this replacement are given in the AMM task “Ref. 5” and in the B/E 
Aerospace VSB 117042-35-001.
- For 22 min generators (PN 117042-2X), fully interchangeable containers manufactured in 
Lübeck, Germany by B/E Aerospace will be delivered. Alternatively, replacement generators 
manufactured in Lenexa, US can also be ordered. They will fit directly in the current 
containers and will not need any adaptation such as the 15 min ones. The 22 min generator 
PN remains the same. Instructions for this replacement are given in the AMM task “Ref. 4 and 
5”.
If an operator has generators PN 117042-XX in stock, with a manufacturing date of 2005 or later, they 
may be used as well (generators with manufacturing date before 2005 shall not be used).
After the replacement, this AOT requires to activate all the removed generators (as per instructions on 
SIL D1019-01) and requires to record for each generator the PN, the date of manufacture, the lot code 
and whether or not the chemical reaction worked properly (checking the colour indicator). The template 
to record the activation results is provided in the appendix A of this AOT. This feedback from the

### Page 3

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A35W008-14 Rev 00 Page 3 of 4 Date: 18-DEC-2014
© AIRBUS S.A.S. 2014. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
operators is necessary for supporting the on-going investigation, will allow to determine the extent of this 
issue and will help to define further continued airworthiness actions.
Please refer to paragraph “7. REPORTING” to submit your feedback.
4. SHORT TERM ACTION
4.1 PLANNING AND MANPOWER
4.1.1 ACCOMPLISHMENT TIMESCALE
Replacement of all oxygen generators PN 117042-XX manufactured in 2000 must be done as far as 
possible in advance of the MPD requirements and in any case not later than June 2015, whichever 
occurs first.
Replacement of all oxygen generators PN 117042-XX manufactured in 2001 must be done as far as 
possible in advance of the MPD requirements and in any case not later than December 2015 whichever 
occurs first. 
4.2 DESCRIPTION
For 15 min generators (PN 117042-0X), please refer to AMM task “Ref. 5” and to B/E Aerospace VSB 
117042-35-001 providing instructions for disassembly, assembly and testing.
For 22 min generators (PN 117042-2X), please refer to the AMM task “Ref. 4 and 5”.
If an operator has generators PN 117042-XX in stock, with a manufacturing date of 2005 or later, they 
may be used as well (generators with manufacturing date before 2005 shall not be used).
This AOT is the subject of an AIRBUS monitored retrofit campaign, which will be detailed in a Retrofit 
Information Letter (RIL). 
For the organisation of this retrofit, you are kindly requested to contact AIRBUS retrofit management 
department:
AIRBUS CUSTOMER SERVICES DIRECTORATE
1 Rond-Point Maurice Bellonte
31707 BLAGNAC CEDEX
France
Tel: (33) 5 67 19 06 22
E-mail: monitored.retrofit@airbus.com
Fax: (33) 5 61 93 27 45
5. FURTHER INFORMATION
5.1 FOLLOW-UP PLAN
Airbus have currently not received any failure report on generators manufactured in 2002 and after. 
However, in order to investigate further this potential premature ageing, a sampling test on generators 
manufactured in 2002 and 2003 will be performed. The results of this sampling will allow Airbus and B/E 
Aerospace to adjust the retrofit and the sampling actions on these units if necessary.  
5.2 IMPACTED DOCUMENTATION

### Page 4

ALERT OPERATORS TRANSMISSION - AOT 
AOT ref: A35W008-14 Rev 00 Page 4 of 4 Date: 18-DEC-2014
© AIRBUS S.A.S. 2014. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT
As explained in paragraph 3.3, the 15 min replacement generators will be delivered with a kit in order to 
adapt the new generator inside the container as described in VSB 117042-35-001. This adaptation will 
lead to a container PN change. The post-MOD container is two way interchangeable with the pre-MOD 
one. The IPC will be updated accordingly.
6. AOT APPROVAL
The technical content of this document is approved under the authority of DOA nr. EASA.21J.031.
7. REPORTING
The results of generator activation and questions about this AOT and are to be sent to Airbus Customer 
Services engineering as soon as possible, after the AOT application, to the attention of:
Mr. Florent FARBOS
Engineer
Emergency & Cabin Systems, Galleys & Lav’s 
Customer Services Engineering - SEEC2
Phone: +33 (0)5 82 05 51 06
Fax: +33 (0)5 61 93 44 25
Mailto:florent.farbos@airbus.com
AIRBUS S.A.S.
1 rond-point Maurice Bellonte
31707 Blagnac Cedex
France
Best Regards,
Jean-Luc MOUYSSET
VICE PRESIDENT ENGINEERING SUPPORT
CUSTOMER SERVICES
Philippe BOUCHERAT
VICE PRESIDENT A300/A310 PROGRAMME
CUSTOMER SERVICES

### Page 5

AOT A35W008-14 - Appendix A
Airline:
Program:
MSN:
Activation ok? 
(colour indicator)
PN MFG Date Lot Number Yes or No
ATA35 - chemical oxygen generators activation results
How many generators activated correctly:
How many generators failed:
Generators info

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.