Copy: Revision 1 ("SB ATR42-27-0118 R1"), 28 pages: PDF https://openairdocs.org/files/sha256/d5/2f/d52fec9ef015a54359ffb4a20e50af89507a370e6f72e76530c3bc89b9034536; text https://openairdocs.org/service-documents/atr/atr42-27-0118/file/d52fec9ef015.md. Rights: © ATR. Filed by the FAA in regulations.gov docket FAA-2025-1354, the docket of AD 2025-20-01. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [ATR](https://openairdocs.org/service-documents/atr.md)
- Type: Service bulletin (Service Bulletin)
- Number: ATR42-27-0118
- Latest revision known: ATR42-27-0118, Revision 1 (OpenAirDocs)
- Page: https://openairdocs.org/service-documents/atr/atr42-27-0118

## Text (28 pages)

Rights: © ATR. Filed by the FAA in regulations.gov docket FAA-2025-1354, the docket of AD 2025-20-01. Not covered by OpenAirDocs’ CC0 dedication. Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

SERVICE BULLETIN ATR42   
Revision No. 01 - Nov 29/24 Service Bulletin No. ATR42-27-0118 
 
  Page TS-1 of TS-3 
 
 
TRANSMITTAL SHEET 
Revision No. 01 
This page transmits Revision No. 01 of Service Bulletin No. ATR42-27-0118. 
General information concerning this document is available in Service Letter No. ATR42-00-5005. 
For any technical request regarding this document, please contact ATR at the following address: 
- through ATRactive at www.atractive.com (select “Request ATR”, Theme “Engineering & 
Maintenance”, Type “Retrofit Engineering”) 
- otherwise by mail at the following address technical.toulouse@atr-aircraft.com 
TITLE: Flight controls - New Avionics Suite - Consolidate TLU command and 
monitoring logics 
 
 
 
 ATR. All rights reserved. Confidential and proprietary document. 
 
This document shall not be reproduced or disclosed to a third party  
without the written consent of ATR. This document and its content  
shall not be used for any purpose other than that for which it is supplied. 
 
ATR, its logo, the distinctive ATR aircraft profiles and patented information  
relating to the ATR aircraft are the exclusive property of ATR and are subject  
to copyright. This document and all information contained herein are the sole 
property of ATR. No intellectual property right is granted through, or induced by,  
the delivery of this document or the disclosure of its content. 
 
This document has been reviewed and was determined to not be subject to U.S. nor E.U. export controls.

### Page 2

SERVICE BULLETIN ATR42 
  
Revision No. 01 - Nov 29/24 Service Bulletin No. ATR42-27-0118 
 
 Page TS-2 of TS-3 
 ATR. All rights reserved. Confidential and proprietary document. 
 
1 – ADDITIONAL WORK 
A- IMPACT ON PROCEDURE 
The changes introduced by this Revision affect all aircraft on which the present Service 
Bulletin has already been applied. 
For these aircraft, perform the functional test of the rudder Travel Limiter Unit as per  
Para. 3.D.(5), except for the following MSN: 
- MSN 1002 if Technical Adaptation ref. SCOB-1508/24 has been embodied. 
B- IMPACT ON COMPONENTS 
The associated kits already delivered remain valid. 
 
2 – TECHNICAL IMPACT ON REVISED PAGES 
Layout changes due to computerization of this revision and to modification of maintenance 
documents references (new S1000D format) are not identified. 
Page PI-3 - Para.1.G., MP task reference ATR-A-24-46-XX-00ZZZ-761Z-A and  
AOM ref. 2024/09 added. 
Page PI-4 - Para. 1.H.(1), AFI corrected, AWD 27-36 deleted, ASD 27-51 and SD 27-23 
added. 
Page AI-3 - Para. 3.D.(1), MP task reference ATR-A-24-4X-XX-00ZZZ-761Z-A modified by 
ATR-A-24-46-XX-00ZZZ-761Z-A. 
Para. 3.D.(2), wording "(ground hydraulic source)" added. 
Para. 3.D.(3), wording "green" added at step 2 of test procedure table. 
Page AI-4 - Para. 3.D.(3), 1B information corrected by 2B at step 9 of test procedure table. 
Para. 3.D.(4), wording "(ground hydraulic source)" added. 
Page AI-5 - Para. 3.D.(5), functional test of the rudder Travel Limiter Unit corrected.

### Page 3

SERVICE BULLETIN ATR42 
  
Revision No. 01 - Nov 29/24 Service Bulletin No. ATR42-27-0118 
 
 Page TS-3 of TS-3 
 ATR. All rights reserved. Confidential and proprietary document. 
 
3 – TABLE OF CONTENTS  
TRANSMITTAL SHEET ................................................................................. Page TS-1 to TS-3 
ACCOMPLISHMENT REPORT ..................................................................... Page AR-1 to AR-1 
PLANNING INFORMATION ............................................................................. Page PI-1 to PI-5 
MATERIAL INFORMATION ............................................................................ Page MI-1 to MI-2 
ACCOMPLISHMENT INSTRUCTIONS ............................................................ Page AI-1 to AI-5 
ILLUSTRATIONS ............................................................................................  Page IL-1 to IL 12 
 
4 – REVISION SEQUENCES  
 
Issue or Revision Date Additional work 
   
Original issue Aug 09/24 - 
Revision No. 01 Nov 29/24 Yes

### Page 4

SERVICE BULLETIN ATR42   
Revision No. 01 - Nov 29/24 Service Bulletin No. ATR42-27-0118 
 
  Page AR-1 
 ATR. All rights reserved. Confidential and proprietary document. 
 
ACCOMPLISHMENT REPORT  
SERVICE BULLETIN No. ATR42-27-0118 
Revision No. 01 
TITLE: Flight controls - New Avionics Suite - Consolidate TLU command and 
monitoring logics 
Send this report: 
- through ATRactive at www.atractive.com (select “Request ATR”, Theme “Engineering & 
Maintenance” and Type “Retrofit - Accomplishment report”) 
- otherwise by mail at the following address “techdesk@atr-aircraft.com” 
Aircraft identification 
Aircraft MSN (on which this Service Bulletin has been accomplished): 
Aircraft registration number: 
Flight cycles: 
Flight hours: 
 
Accomplishment date of this Service Bulletin: 
 
 
Maintenance organization identification 
Maintenance organization name: 
Name & Signature: 
Date:

### Page 5

SERVICE BULLETIN ATR42 
  
 
Revision No. 01 - Nov 29/24 Service Bulletin No. ATR42-27-0118 
 
  Page PI-1  
 ATR. All rights reserved. Confidential and proprietary document. 
 
COMPLIANCE:  RECOMMENDED    MODIFICATION: 10469 L3941 
 
TITLE: Flight controls - New Avionics Suite - Consolidate TLU command and 
monitoring logics 
1. PLANNING INFORMATION 
A. EFFECTIVITY 
(1) Aircraft models 
The approved change used to generate this document has been certified on the 
following ATR42 models: 
ATR42-200 ATR42-300 ATR42-320 ATR42-400 ATR42-500 
NO NO NO YES YES 
 
(2) Aircraft 
MSN Kit(s) S270118 
859, 1001, 1002, 1003, 1004, 1005, 1006, 1007, 
1008, 1009, 1010, 1011, 1012, 1013, 1014, 
1016, 1017, 1018, 1019, 1201, 1202, 1203, 
1204, 1205, 1206, 1207, 1208, 1209, 1210, 
1211, 1212, 1213, 1214, 1215, 1216, 1217, 
1218, 1219, 1401, 1402, 1403, 1404, 1405, 
1406, 1407, 1408, 1409, 1410, 1411, 1412, 
1413, 1414, 1415, 1416, 1417, 1418, 1419, 
1601, 1602, 1603, 1605, 1606, 1607, 1608, 
1609, 1610, 1611, 1612, 1613, 1614, 1615, 
1616 
A01 + A02 
For each aircraft MSN, operator should order the mentioned kit(s). 
Other parts or equipment could be required for embodiment of this Service Bulletin. 
Please refer to chapter "MATERIAL INFORMATION" for details.

### Page 6

SERVICE BULLETIN ATR42 
  
Revision No. 01 - Nov 29/24 Service Bulletin No. ATR42-27-0118 
 
  Page PI-2  
 ATR. All rights reserved. Confidential and proprietary document. 
 
NOTE: This Service Bulletin is applicable only on aircraft on which modification  
No. 05948 has been embodied. 
(3) Spares 
The following stock items are modifiable (or not) according to the table below. 
None. 
B. REASON 
It has been evidenced that an erroneous monitoring of the rudder TLU (Travel Limitation 
Unit) could occur when the aircraft is flying above 195kt due to the fact that the logic only 
takes into account ADC1 or ADC2 input.  
Accomplishment of this Service Bulletin consists in installing two relays and associated 
wiring in order to consolidate TLU command and monitoring logics considering both ADC1 
and ADC2 inputs. 
For additional information regarding this Service Bulletin, refer to the AOM ref. 2024/09. 
The change introduced by this Service Bulletin impacts the Time Limits. 
COMPLIANCE: Accomplishment of this Service Bulletin is recommended by ATR. 
C. DESCRIPTION 
Accomplishment of this Service Bulletin consists in carrying out the following jobs: 
(1) On shelf 91VU, installation of relay (FIN 32CY) 
(2) On shelf 92VU, installation of relay (FIN 31CY) 
(3) Wiring modification 
D. APPROVAL 
The technical content of this document is approved under the authority of  
the DOA ref. EASA.21J.044.

### Page 7

SERVICE BULLETIN ATR42 
  
Revision No. 01 - Nov 29/24 Service Bulletin No. ATR42-27-0118 
 
  Page PI-3  
 ATR. All rights reserved. Confidential and proprietary document. 
 
E. MANPOWER 
 Manhours 
Mechanic  None 
Electrician 40 
Total manhours 40 
Elapsed time (hours) 25 
 
The above estimates are only provided for general guidance in operator's modification 
planning. 
NOTE: This Service Bulletin assumes that the aircraft has been placed in the appropriate 
maintenance configuration. The manhours/elapsed time estimates do not include 
preparation for the modification, non-productive elapsed time or administrative 
functions. 
F. W EIGHT AND BALANCE  
Effect on weight : + 0.129 kg (+ 0.284 lb). 
Effect on balance : + 0.718 kg.m (+ 62.319 lb.in). 
G. REFERENCES 
The following publications have to be used during accomplishment of this Service Bulletin: 
AOM : 2024/09     
       
MIPD : 25-13-10     
       
MP : 20-21-21 
ATR-A-24-4X-XX-00ZZZ-561Z-A 
ATR-A-24-4X-XX-00ZZZ-761Z-A 
ATR-A-24-46-XX-00ZZZ-761Z-A 
ATR-A-25-13-10-01ZZZ-520Z-A 
ATR-A-25-13-10-01ZZZ-720Z-A 
ATR-A-27-23-XX-00ZZZ-340Z-A 
ATR-A-29-XX-XX-01ZZZ-562Z-A 
ATR-A-29-XX-XX-01ZZZ-762Z-A

### Page 8

SERVICE BULLETIN ATR42 
  
Revision No. 01 - Nov 29/24 Service Bulletin No. ATR42-27-0118 
 
  Page PI-4  
 ATR. All rights reserved. Confidential and proprietary document. 
 
The following modifications and/or retrofit documents are mentioned on this Service 
Bulletin: 
Modification Retrofit document Title 
   
05948 - NAVIGATION - INSTALL NEW AVIONICS SUITE 
   
H. AFFECTED PUBLICATIONS 
(1) Maintenance documentation 
The following maintenance manuals will be updated after receipt of the 
Accomplishment Report by ATR: 
AFI : 27-23 
   
ASD : 27-23 
27-51 
42-11 
   
AWD : 27-23 
27-51 
31-53 
42-11 
91-10 
AWL   
   
MIPD : 27-23 
   
MP : 27-23 
   
SD : 27-23 
   
(2) Operational documentation 
The following operational manuals are impacted.  
Operators should verify the List of Modifications (LOM) of these manuals to verify that 
the modification No. 10469 is mentioned. 
AFM : The EASA AFM revision is approved. In case of specific AFM issued for a 
local Authority, the operator must make sure the corresponding AFM revision 
has been approved by its local Authority.

### Page 9

SERVICE BULLETIN ATR42 
  
Revision No. 01 - Nov 29/24 Service Bulletin No. ATR42-27-0118 
 
  Page PI-5  
 ATR. All rights reserved. Confidential and proprietary document. 
 
FCOM   
   
MMEL   
   
QRH   
   
In case the material is not purchased through a kit, the operator should contact ATR 
at the following address to obtain the impacted operational documentation: 
ATR UPGRADE SERVICES TOULOUSE 
e-mail : Upgrade-Services@atr-aircraft.com

### Page 10

SERVICE BULLETIN ATR42 
  
Revision No. 01 - Nov 29/24 Service Bulletin No. ATR42-27-0118 
 
  Page MI-1 
 ATR. All rights reserved. Confidential and proprietary document. 
 
2. MATERIAL INFORMATION 
A. MATERIAL - COST AND AVAILABILITY 
(1) Kits 
Kits cost and availability, or any further commercial information about Service Bulletin, 
may be consulted through ATRactive or operator should contact ATR at the following 
addresses: 
www.atractive.com 
 
ATR UPGRADE SERVICES TOULOUSE 
e-mail : Upgrade-Services@atr-aircraft.com 
 
Or operator should contact the ATR center it is related to, according to its operational 
area, at the following addresses: 
ATR AMERICAS SERVICES MIAMI 
e-mail : commercial.services.miami@atr-aircraft.com 
 
ATR EASTERN SUPPORT SINGAPORE 
e-mail : commercial.services.singapore@atr-aircraft.com 
 
Operator should place a purchase order specifying concerned MSN, Service Bulletin 
reference and kits reference (according to paragraph 1.A.) through ATRactive or to 
the ATR center it is related to according to its operational area. 
B. LIST OF COMPONENTS 
Item Part Number Qty Description 
    
 Kit S270118A01   
    
2 E0247A0S 2 Base (FIN 31CY-A and 32CY-A) 
4 E0427-01 1 Retainer (FIN 31CY-A1) 
1 E0666D28A0 2 Relay (FIN 31CY and 32CY) 
3 MS21042-04 5 Nut 
5 NAS1101-04-6 1 Screw 
6 NAS1149FN416P 1 Washer 
- NSA935401-03 150 Cable tie 
- NSA935401-04 150 Cable tie  
- NSA935401-05 150 Cable tie

### Page 11

SERVICE BULLETIN ATR42 
  
Revision No. 01 - Nov 29/24 Service Bulletin No. ATR42-27-0118 
 
  Page MI-2 
 ATR. All rights reserved. Confidential and proprietary document. 
 
Item Part Number Qty Description 
    
 Kit S270118A02   
    
- S9110252400195 1 Placard set 
- S9110308400195 1 Bundle 
    
C. LIST OF MATERIALS - OPERATOR SUPPLIED 
None. 
D. SPECIAL TOOLS 
Accomplishment of this Service Bulletin requires use of the following special tools: 
None.

### Page 12

SERVICE BULLETIN ATR42 
  
Revision No. 01 - Nov 29/24 Service Bulletin No. ATR42-27-0118 
 
  Page AI-1 
 ATR. All rights reserved. Confidential and proprietary document. 
 
3. ACCOMPLISHMENT INSTRUCTIONS 
A. GENERAL 
The following instructions assume that work will be accomplished when the aircraft is in 
the appropriate maintenance configuration. 
B. JOB SET-UP 
(1) De-energize the aircraft electrical network and connect the aircraft to ground as per 
MP ATR-A-24-4X-XX-00ZZZ-561Z-A. 
(2) On 80VU and 90VU, remove lining panels 211WZ, 211XZ, 213CZ, 214CZ, 221FZ, 
221KZ, 222FZ and 222KZ as per MP ATR-A-25-13-10-01ZZZ-520Z-A. 
(3) In flight compartment, remove central ceiling panel 213DC (refer to MIPD 25-13-10). 
C. MODIFICATION 
(1) On shelf 91VU, installation of relay (FIN 32CY) 
As per figure 1 
Install all the parts listed in the following table. 
    INSTALLATION 
Item Description Part Number Qty New Qty from Removal Figure 
      
1 Relay (FIN 32CY) E0666D28A0 1 - 1 
2 Base (FIN 32CY-A) E0247A0S 1 - 1 
3 Nut MS21042-04 2 - 1 
      
 
Specific instruction(s): 
- Position and affix placard 32CY supplied in placard set S9110252400195 to identify 
the relay item 1 (FIN 32CY).

### Page 13

SERVICE BULLETIN ATR42 
  
Revision No. 01 - Nov 29/24 Service Bulletin No. ATR42-27-0118 
 
  Page AI-2 
 ATR. All rights reserved. Confidential and proprietary document. 
 
(2) On shelf 92VU, installation of relay (FIN 31CY) 
As per figure 2 
Install all the parts listed in the following table. 
    INSTALLATION 
Item Description Part Number Qty New Qty from Removal Figure 
      
1 Relay (FIN 31CY) E0666D28A0 1 - 2 
2 Base (FIN 31CY-A) E0247A0S 1 - 2 
3 Nut MS21042-04 3 - 2 
4 Retainer (FIN 31CY-A1) E0427-01 1 - 2 
5 Screw NAS1101-04-6 1 - 2 
6 Washer NAS1149FN416P 1 - 2 
      
 
Specific instruction(s): 
- To allow the installation of the 31CY relay on the 92VU shelf, it is necessary  
to move by one hole all the relays having a position lower than position B14. 
- Position and affix placard 31CY supplied in placard set S9110252400195 to identify 
the relay item 1 (FIN 31CY). 
(3) Wiring modification 
NOTE: At each wire installation, the following instructions must be observed:  
Cut the wires to the necessary length, crimp the terminals and connect 
accordingly.  
Perform continuity test of the new wiring.  
Attach with cable ties as per MP 20-21-21. 
As per wiring diagrams Figures 3 to 9. 
(a) Remove wires according to wiring diagrams. 
(b) Install, on existing routing, wires according to wiring diagrams, supplied in bundle 
S9110308400195. 
For details refer to Hook-up charts Figures 10 to 12.

### Page 14

SERVICE BULLETIN ATR42 
  
Revision No. 01 - Nov 29/24 Service Bulletin No. ATR42-27-0118 
 
  Page AI-3 
 ATR. All rights reserved. Confidential and proprietary document. 
 
D. TESTS 
(1) Re-energize the aircraft electrical AC and DC as per  
MP ATR-A-24-46-XX-00ZZZ-761Z-A. 
(2) Pressurize the green hydraulic system (ground hydraulic source) as per 
 MP ATR-A-29-XX-XX-01ZZZ-762Z-A. 
(3) Perform an operational test of the TLU Monitoring Logic as per the following 
procedure: 
ACTION RESULT 
  
On the Engine and Warning Display (EWD), in 
the TRIM/FLAP window: 
 
1. Make sure that the green “TLU LO SPEED” 
message is displayed. 
 
2. On the Overhead Panel, on the MFC section 
of panel 25VU, release 1B pushbutton. 
Make sure that the OFF legend comes on, on 
the 1B pushbutton. 
3. On 21VU, open circuit breaker 
24FL (PRIM REF/ADC 2/ICP F/O GND 
SPLY). 
After 25 seconds, check the following alerts: 
• Single Chime operates. 
• Master Caution lights ﬂash on 133VM and 
134VM. 
• On the EWD alert window, the FLT CTL 
TLU message is displayed. 
• On the Overhead Panel, on the FLT CTL 
section of panel 25VU, the FAULT 
indicator light comes on. 
4. Close circuit breaker 24FL (PRIM REF/ 
ADC 2/ICP F/O GND SPLY). 
Make sure that all the alerts mentioned here 
above are off. 
5. On the Overhead Panel, on the MFC section 
of panel 25VU, press 1B pushbutton. 
Make sure that the OFF legend comes off, on 
the 1B pushbutton. 
6. On the Overhead Panel, on the MFC section 
of panel 25VU, release 2B pushbutton. 
Make sure that the OFF legend comes on, on 
the 2B pushbutton. 
7. On 21VU, open the circuit breakers: 
• 3FL1 (ADS/ADC 1 EMER SPLY) 
• 4UA1 (MFC/1 A AUX/ADC 1 HOT SPLY). 
After 25 seconds, check the following alerts: 
• Single Chime operates

### Page 15

SERVICE BULLETIN ATR42 
  
Revision No. 01 - Nov 29/24 Service Bulletin No. ATR42-27-0118 
 
  Page AI-4 
 ATR. All rights reserved. Confidential and proprietary document. 
 
ACTION RESULT 
  
 • Master Caution lights ﬂash on 133VM and 
134VM. 
On the EWD alert window, the FLT CTL TLU 
message is displayed. 
On the Overhead Panel, on the FLT CTL 
section of panel 25VU, the FAULT indicator 
light comes on. 
8. Close the circuit breakers: 
• 3FL1 (ADS/ADC 1 EMER SPLY). 
• 4UA1 (MFC/1 A AUX/ADC 1 HOT SPLY). 
Make sure that all the alerts mentioned here 
above are off. 
9. On the Overhead Panel, on the MFC section 
of panel 25VU, press 2B pushbutton. 
Make sure that the OFF legend comes off, on 
the 2B pushbutton. 
10. Open 21VU, open the circuit breakers: 
• 3FL1 (ADS/ADC 1 EMER SPLY). 
• 4UA1 (MFC/1 A AUX/ADC 1 HOT SPLY). 
• 24FL (PRIM REF/ADC 2/ICP F/O GND 
SPLY). 
Make sure that the green “TLU LO SPEED” 
message goes out of view, on EWD, in the 
TRIM/FLAP window. 
After 5 seconds, check the following alerts: 
• Single Chime operates. 
• Master Caution lights flash on 133VM and 
134VM. 
On the EWD alert window, the FLT CTL TLU 
message is displayed. 
On the Overhead Panel, on the FLT CTL 
section of panel 25VU, the FAULT indicator 
light comes on. 
11. Close the circuit breakers: 
• 3FL1 (ADS/ADC 1 EMER SPLY). 
• 4UA1 (MFC/1 A AUX/ADC 1 HOT SPLY). 
• 24FL (PRIM REF/ADC 2/ICP F/O GND 
SPLY). 
Make sure that all the alerts mentioned here 
above are off. 
  
 
(4) Depressurize the green hydraulic system (ground hydraulic source) as per  
MP ATR-A-29-XX-XX-01ZZZ-562Z-A.

### Page 16

SERVICE BULLETIN ATR42 
  
Revision No. 01 - Nov 29/24 Service Bulletin No. ATR42-27-0118 
 
  Page AI-5 
 ATR. All rights reserved. Confidential and proprietary document. 
 
(5) Perform the functional test of the rudder Travel Limiter Unit as per  
MP ATR-A-27-23-XX-00ZZZ-340Z-A ensuring to follow the common procedures and 
chapters with the effectivity "(POST SB 27-0118)" when specified. 
NOTE: If involved chapters with the effectivity "(POST SB 27-0118)" are not available 
in ATRnavX, use the advance copy of the MP available in the  
AOM ref. 2024/09. 
E. CL OSE -UP 
(1) On 80VU and 90VU, reinstall lining panels 211WZ, 211XZ, 213CZ, 214CZ, 221FZ, 
221KZ, 222FZ and 222KZ as per MP ATR-A-25-13-10-01ZZZ-720Z-A. 
(2) In flight compartment, re-install central ceiling panel 213DC (refer to MIPD 25-13-10). 
(3) Re-energize the aircraft electrical network and disconnect the aircraft from ground as 
per MP ATR-A-24-4X-XX-00ZZZ-761Z-A.

### Page 17 (OCR)

ATR
SERVICE BULLETIN ATR42
- 91VU
/ (FIN 2CY. POSITION COB)
3(2 PLACES)
00000L
32CY
MFC1  00000
(FIN 1UA1)
MA 000CI
On shelf 91VU, installation of relay (FIN 32CY)
Figure 1
Revision No. 01 - Nov 29/24  Service Bulletin No. ATR42-27-0118
Page IL-1
© ATR. All rights reserved. Confidential and proprietary document.

### Page 18 (OCR)

ATR
SERVICE BULLETIN ATR42
- 92VU
MFC2
(FIN 1UA2)  DETAIL C
SEE DETAIL C
1 (FIN 31CY, POSITION B14)
On shelf 92VU, installation of relay (FIN 31CY)
Figure 2
Revision No. 01 - Nov 29/24  Service Bulletin No. ATR42-27-0118
Page IL-2
© ATR. All rights reserved. Confidential and proprietary document.

### Page 19 (OCR)

ATR
SERVICE BULLETIN ATR42
BEFORE
- 816VC  HD
+.4211-2050+  9A  CAC1
1TF1
81VU
213
AFTER
A 816VC  HD
SEE FIG. 9 -  24  - 0499  9A  CAC1
1TF1
- EXISTING WIRE +//// DELETED WIRE  - NEW WIRE  → WIRE STOWED
D// OLD HOOK-UP  Dor000 NEW HOOK-UP  F.R.: FOR REFERENCE
NOTE: UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2723
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE CF24 GAUGE
Wiring Diagram
Figure 3
Revision No. 01 - Nov 29/24  Service Bulletin No. ATR42-27-0118
Page IL-3
© ATR. All rights reserved. Confidential and proprietary document.

### Page 20 (OCR)

ATR
SERVICE BULLETIN ATR42
BEFORE
CAC2
1TF2
A 822VC  22
SEE FIG. 8 •  781111170099/11126  70048+///+  OR
820VT
821VD
820VC
35  73153-5045+
36  7 3153-5046 / /  - SEE FIG. 8
821VD
82VU
213
AFTER
HC  822VC  A
CAC2  0466-  SEE FIG. 9
1 TF2
82VU
213
- EXISTING WIRE ++ DELETED WIRE  - NEW WIRE  → WIRE STOWED
DA// OLD HOOK-UP  D00000 NEW HOOK-UP  F.R. : FOR REFERENCE
NOTE: UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2723
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE CF24 GAUGE
Wiring Diagram
Figure 4
Revision No. 01 - Nov 29/24  Service Bulletin No. ATR42-27-0118
Page IL-4
© ATR. All rights reserved. Confidential and proprietary document.

### Page 21 (OCR)

ATR
SERVICE BULLETIN ATR42
BEFORE
835VC
SEE FIG. 8 -  541421120741.
u
37-3153-5047+1  38+3153-5048+1+1111111111  830VT  835VC A  59  - SEE FIG. 8
831VD
83VU
213
AFTER
- 0500
F.R.
830VT
830VC A
' 0501-
835VC A  SEE FIG. 9
0502
83VU
213
- EXISTING WIRE +///+ DELETED WIRE  - NEW WIRE  > WIRE STOWED
D////OLDHOOK-UP  D0000Đ NEW HOOK-UP  F.R. : FOR REFERENCE
NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2723
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE CF24 GAUGE
Wiring Diagram
Figure 5
Revision No. 01 - Nov 29/24  Service Bulletin No. ATR42-27-0118
Page IL-5
© ATR. All rights reserved. Confidential and proprietary document.

### Page 22 (OCR)

ATR
SERVICE BULLETIN ATR42
BEFORE
911VC  13
SEE FIG. 8-  11315339871111
- - F.R.
912VT
91VU
214
AFTER
A 911VC
• 0508 -  0509-  13
K  - 0510
SEE FIG. 9  F.R
910VC  912VT
13
- 0462-  R
S
F.R.
- 0463
912VT  0520-
18VG  32CY
910VR
91VU
214
— EXISTING WIRE +// DELETED WIRE  - NEW WIRE  → WIRE STOWED
D/// OLD HOOK-UP  D0000 NEW HOOK-UP  F.R. :  FOR REFERENCE
NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2723
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE CF24 GAUGE
Wiring Diagram
Figure 6
Revision No. 01 - Nov 29/24  Service Bulletin No. ATR42-27-0118
Page IL-6
© ATR. All rights reserved. Confidential and proprietary document.

### Page 23 (OCR)

ATR
SERVICE BULLETIN ATR42
BEFORE
SEE FIG. 8 —  +3+3153-4623-+7774K  A 988VC
— F.R.
920VT
92VU
214
AFTER
A 928VC
36  0511
78  • 0512  F.R
- 70
SEE FIG. 9  920VT
• 0514  2  0516
- 0515
10
= DC2  • 0521  • 0517
6VG  F.R
31CY  920VT
921VR
92VU
214
- EXISTING WIRE +//// DELETED WIRE  - NEW WIRE  → WIRE STOWED
D/// OLD HOOK-UP  Dooo00 NEW HOOK-UP  F.R. :  FOR REFERENCE
NOTE: UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2723
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE CF24 GAUGE
Wiring Diagram
Figure 7
Revision No. 01 - Nov 29/24  Service Bulletin No. ATR42-27-0118
Page IL-7
© ATR. All rights reserved. Confidential and proprietary document.

### Page 24 (OCR)

ATR
SERVICE BULLETIN ATR42
BEFORE
835VC  53VC
830VC
F.R.-
822VC
SEE FIG. 4 -  <2723-0050<
SEE FIG. 4 -  820VC  +A712 - SE107  988VC
- EXISTING WIRE + DELETED WIRE  - NEW WIRE  → WIRE STOWED  NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3153
D//// OLD HOOK-UP Do NEW HOOK-UP  FOR REFERENCE  UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2M  JNLESS OTHERWISE SPECIFIED ALL WIRES ARE CF24 GAUGE
Wiring Diagram
Figure 8
Revision No. 01 - Nov 29/24  Service Bulletin No. ATR42-27-0118
Page IL-8
© ATR. All rights reserved. Confidential and proprietary document.

### Page 25 (OCR)

ATR
SERVICE BULLETIN ATR42
AFTER
11VC
=→ SEEFIG. 6
816VC
SEE FIG. 3-  10VC
- SEE FIG. 6
835V
SEE FIG. 5-
28VC
830VC
F.R. —
SEE FIG. 5-  SEE FIG. 7
83VU
213
822VC
SEE FIG. 4 -
D/// OLD HOOK-UP  - EXISTING WIRE +// DELETED WIRE  Dooss NEw Hook-uP  NOTE: UNLESS OTHER BE SPECHED ALL ROUTES ARE A CAUCATION WITH ATA 2723
Wiring Diagram
Figure 9
Revision No. 01 - Nov 29/24  Service Bulletin No. ATR42-27-0118
Page IL-9
© ATR. All rights reserved. Confidential and proprietary document.

### Page 26

SERVICE BULLETIN ATR42 
  
Revision No. 01 - Nov 29/24 Service Bulletin No. ATR42-27-0118 
 
  Page IL-10 
 ATR. All rights reserved. Confidential and proprietary document. 
 
 
 
L END 1 LEAD END 2   
i 
n Zone or Variant FIN Term. Terminal P/N Wire Ident Type Length Zone or Variant FIN Term. Terminal P/N Instructions Figure 
e Panel      Gauge cm Panel       
1 81VU  1TF1-HD 9A  4211-2050 CF24  81VU  816VC 9  D 3 
2 81VU  1TF1-HD 9A EN3155-077F2222 2723-0499 CF24 200 81VU  816VC 24 EN3155-008M2222 A 3 
3                
4 82VU  820VT22 P  2723-0048 CF24  82VU  821VD-A 11  D 4 
5 82VU  821VD-A 26  2723-0049 CF24  82VU  822VC 78  D 4 
6 82VU  1TF2-HC 9C  4211-2118 CF24  82VU  820VT22 G  D 4 
7 82VU  820VT22 Y  3153-5045 CF24  82VU  821VD-A 35  D 4 
8 82VU  820VC 36  3153-5046 CF24  82VU  821VD-A 36  D 4 
9 82VU  1TF2-HC 9C EN3155-077F2222 2723-0466 CF24 200 82VU  822VC 1 EN3155-008M2222 A 4 
10                
11 83VU  830VT11 R  4211-2074 CF24  83VU  835VC 54  D 5 
12 83VU  830VT11 T  3153-5047 CF24  83VU  831VD-A 37  D 5 
13 83VU  835VC 59  3153-5048 CF24  83VU  831VD-A 38  D 5 
14 83VU  830VT11 U EN3155-016M2222 2723-0500 CF24 200 83VU  831VD-A 37 EN3155-003F2222 A 5 
15 83VU  830VC 8 EN3155-008M2222 2723-0501 CF24 200 83VU  831VD-A 38 EN3155-003F2222 A 5 
16 83VU  830VT11 R EN3155-016M2222 2723-0502 CF24 200 83VU  835VC 59 EN3155-008M2222 A 5 
17                
18 91VU  912VT13 S  3153-3398 CF24  91VU  911VC 8  D 6 
19 91VU  910VC 26 EN3155-008M2222 2723-0462 CF24 200 91VU  912VT13 R EN3155-016M2222 A 6 
20 91VU  18VG / EN3155-015F2018 2723-0463 CF24 200 91VU  32CY-A Z E0252DK2002 A 6 
21 91VU  32CY-A B E0252DK2002 2723-0508 CF24 200 91VU  911VC 8 EN3155-008M2222 A 6 
22 91VU  32CY-A 4 E0252DK2002 2723-0509 CF24 200 91VU  911VC 51 EN3155-008M2222 A 6 
23 91VU  910VR-A 3 EN3155-015F2018 2723-0510 CF24 200 91VU  912VT13 K EN3155-016M2222 A 6 
24 91VU  32CY-A X E0252DK2002 2723-0520 CF24 200 91VU  910VR-A 20 EN3155-015F2018 A 6 
25                
 
 Hook-up chart 
 Figure 10 
 
A = ADDED SH = SHIELD 
D = DELETED W.F. = WIRE FERRULE 
M1 = END 1 MODIFIED W.S. = WIRE STOWED 
M2 = END 2 MODIFIED

### Page 27

SERVICE BULLETIN ATR42 
  
Revision No. 01 - Nov 29/24 Service Bulletin No. ATR42-27-0118 
 
  Page IL-11 
 ATR. All rights reserved. Confidential and proprietary document. 
 
 
 
L END 1 LEAD END 2   
i 
n Zone or Variant FIN Term. Terminal P/N Wire Ident Type Length Zone or Variant FIN Term. Terminal P/N Instructions Figure 
e Panel      Gauge cm Panel       
1 92VU  920VT10 K  3153-4623 CF24  92VU  988VC 12  D 7 
2 92VU  920VT10 K EN3155-016M2222 2723-0511 CF24 200 92VU  928VC 36 EN3155-008M2222 A 7 
3 92VU  31CY-A Z E0252DK2002 2723-0512 CF24 200 92VU  928VC 78 EN3155-008M2222 A 7 
4 92VU  31CY-A B E0252DK2002 2723-0513 CF24 200 92VU  928VC 70 EN3155-008M2222 A 7 
5 92VU  31CY-A 2 E0252DK2002 2723-0514 CF24 200 92VU  928VC 39 EN3155-008M2222 A 7 
6 92VU  6VG / EN3155-015F2018 2723-0515 CF24 200 92VU  31CY-A 4 E0252DK2002 A 7 
7 92VU  31CY-A A E0252DK2002 2723-0516 CF24 200 92VU  920VT10 H EN3155-016M2222 A 7 
8 92VU  920VT10 U EN3155-016M2222 2723-0517 CF24 200 92VU  921VR-A 30 EN3155-015F2018 A 7 
9 92VU  31CY-A X E0252DK2002 2723-0521 CF24 200 92VU  921VR-A 14 EN3155-015F2018 A 7 
10                
11 81VU  816VC-A 9  4211-2070 CF24  83VU  835VC-A 54  D 8 
12 82VU  822VC-A 78  2723-0050 CF24  83VU  830VC-A 51  D 8 
13 213  53VC-A J  3153-2428 CF24  83VU  835VC-A 59  D 8 
14 213  53VC J  3153-2431 CF24  91VU  911VC-A 8  D 8 
15 213  52VC-A D  3153-4611 CF24  82VU  820VC-A 36  D 8 
16 213  52VC D  3153-4617 CF24  92VU  988VC-A 12  D 8 
17                
18 213  53VC-A X EN3155-019F2018 2723-0503 CF24 150 81VU  816VC-A 24 EN3155-003F2222 A 9 
19 213  232VC-A U EN3155-019F2018 2723-0465 CF24 150 82VU  822VC-A 1 EN3155-003F2222 A 9 
20 213  232VC-A V EN3155-003F2222 2723-0050 CF24 150 83VU  830VC-A 51 EN3155-003F2222 A 9 
21 213  232VC-A Z EN3155-019F2018 2723-0504 CF24 150 83VU  830VC-A 8 EN3155-003F2222 A 9 
22 213  53VC-A J EN3155-019F2018 2723-0505 CF24 200 83VU  835VC-A 59 EN3155-003F2222 A 9 
23 213  53VC J EN3155-018M2018 2723-0506 CF24 350 91VU  911VC-A 8 EN3155-003F2222 A 9 
24 213  53VC X EN3155-018M2018 2723-0507 CF24 350 91VU  911VC-A 51 EN3155-003F2222 A 9 
25 91VU  910VC-A 26 EN3155-003F2222 2723-0460 CF24 100 92VU  928VC-A 36 EN3155-003F2222 A 9 
 
 Hook-up chart 
 Figure 11 
 
A = ADDED SH = SHIELD 
D = DELETED W.F. = WIRE FERRULE 
M1 = END 1 MODIFIED W.S. = WIRE STOWED 
M2 = END 2 MODIFIED

### Page 28

SERVICE BULLETIN ATR42 
  
Revision No. 01 - Nov 29/24 Service Bulletin No. ATR42-27-0118 
 
  Page IL-12 
 ATR. All rights reserved. Confidential and proprietary document. 
 
 
 
L END 1 LEAD END 2   
i 
n Zone or Variant FIN Term. Terminal P/N Wire Ident Type Length Zone or Variant FIN Term. Terminal P/N Instructions Figure 
e Panel      Gauge cm Panel       
1 213  232VC U EN3155-018M2018 2723-0461 CF24 550 92VU  928VC-A 78 EN3155-003F2222 A 9 
2 213  232VC V EN3155-018M2018 2723-0518 CF24 550 92VU  928VC-A 70 EN3155-003F2222 A 9 
3 213  232VC Z EN3155-018M2018 2723-0519 CF24 550 92VU  928VC-A 39 EN3155-003F2222 A 9 
4                
5                
6                
7                
8                
9                
10                
11                
12                
13                
14                
15                
16                
17                
18                
19                
20                
21                
22                
23                
24                
25                
 
 Hook-up chart 
 Figure 12 
 
A = ADDED SH = SHIELD 
D = DELETED W.F. = WIRE FERRULE 
M1 = END 1 MODIFIED W.S. = WIRE STOWED 
M2 = END 2 MODIFIED

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.