# B/E Aerospace Service Bulletin 22CXX-0100-35-003

Copy: Revision 2 ("BE_22CXX-0100 35-003_R02"), 38 pages: PDF https://openairdocs.org/files/sha256/78/5f/785f285cc286c102efb42dbd8864b6dbd5651e3a6e1d37a4dfea6f5fec9d03be; text https://openairdocs.org/service-documents/be-aerospace/22cxx-0100-35-003/file/785f285cc286.md. Rights: © B/E Aerospace. Filed by the FAA in regulations.gov docket FAA-2016-4228; AD 2016-25-08 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [B/E Aerospace](https://openairdocs.org/service-documents/be-aerospace.md)
- Type: Service bulletin (Service Bulletin)
- Number: 22CXX-0100-35-003
- Latest revision known: 22CXX-0100-35-003, Revision 2, dated July 10, 2014 (OpenAirDocs)
- Page: https://openairdocs.org/service-documents/be-aerospace/22cxx-0100-35-003

## ADs that cite it (2) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2016-25-08](https://openairdocs.org/ad/2016-25-08.md), effective Jan 20, 2017: Revisions 1 and 2
- [AD 2014-13-12](https://openairdocs.org/ad/2014-13-12.md), effective Sep 9, 2014: Revision 1

Also cited in [2 proposed ADs](https://openairdocs.org/service-documents/be-aerospace/22cxx-0100-35-003/proposed.md).

## Text (38 pages)

Rights: © B/E Aerospace. Filed by the FAA in regulations.gov docket FAA-2016-4228; AD 2016-25-08 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 1 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
 
 
 
REVISION TRANSMITTAL SHEET 
 
 
 
 
 
 
This sheet transmits Revision 02 to Service Bulletin 22CXX-0100-35-003 
 
REASON FOR REVISION 
 
 
 
Serial Number sequence added. 
 
 
 
NOTES:  The Service Bulletin is fully re-printed. 
  Bars on the right margin identify the changes 
 
 
REVISION SEQUENCE 
 
ORIGINAL:   MAR/17/2011 
 
Revision 1:  DEC/20/2011 
 
Revision 2  JUL/10/2014 
 
 
 
 
 
 
 
 
 
Date:    JUL/10/2014

### Page 2

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 2 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
 
ATA SYSTEM:  35 
 
TITLE: OXYGEN – CHEMICAL PASSENGER EMERGENCY OXYGEN CONTAINER- 
IMPROVEMENT OF THE MASK HOSE CONNECTION 
1. PLANNING INFORMATION 
A. EFFECTIVITY 
This service bulletin is applicable to all chemical oxygen container assemblies  
Type II (15/22 Minutes) that are listed below.  
Spare units may be affected as well 
(1) Part numbers of the affected passenger emergency oxygen container assemblies: 
Part Numbers Type II 15 Min. Part Numbers Type II 22 Min. 
22C15L120080100 
22C15L120100100 
22C15L120120100 
22C15L120220100 
22C15L120280100 
22C15L120640100 
22C15L150020100 
22C15L150320100 
22C15L150460100 
22C15L150640100 
22C15L240080100 
22C15L240100100 
22C15L240120100 
22C15L240220100 
22C15L240280100 
22C15L240320100 
22C15L240640100 
 
22C22L120100100 
22C22L120220100 
22C22L150020100 
22C22L150040100 
22C22L150460100 
22C22L240100100 
22C22L240220100

### Page 3

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 3 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
 
(2) Serial numbers of the affected passenger emergency oxygen container 
assemblies are listed below: 
 
from ARBA-0000 to ARBA-9999 
from ARBB-0000 to ARBB-9999 
from ARBC-0000 to ARBC-9999 
from ARBD-0000 to ARBD-9999 
from ARBE-0000 to ARBE-9999 
from BEBE-0000 to BEBE-9999 
from BEBF-0000 to BEBF-9999 
from BEBH-0000 to BEBH-9999 
from BEBK-0000 to BEBK-9999 
from BEBL-0000 to BEBL-9999 
from BEBM-0000 to BEBM-9999 
 
NOTE: As far as still available at the Airbus final assembly line a few aircraft have 
already been reworked before handover to the operator .Those units have 
been marked with a green dot on the test button label as shown below and do 
not need further rework. 
 
 
B. CONCURRENT REQUIREMENTS 
Not Applicable 
C. REASON 
During manufacturing at the manufacturer facility particles had been detected in the 
oxygen generator manifolds. Investigation revealed that those particles (chips) are chafed 
from the mask hoses when installed onto the generator outlets. It was found out that a 
defective mask hose installation device has caused the chips. Such chips may reduce or 
block the oxygen supply. 
A replacement of the manifold is necessary.  
Green Dot

### Page 4

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 4 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
D. DESCRIPTION 
This Service Bulletin specifies the replacement of the Manifold.  
(See Para. 3. ACCOMPLISHMENT INSTRUCTIONS of this SB) 
E. COMPLIANCE 
Mandatory 
F. APPROVAL 
The technical content of this document is approved under the authority of  
DOA No. EASA.21J.031. 
G. MANPOWER 
For 22C15 – 0100 Series Oxygen Container 
This Service Bulletin may be accomplished on the Aircraft or in the workshop. The 
estimated time to do the work in this Service Bulletin is 0.30 hours.  
(1) Open the door of the oxygen container.  
(2) Remove and secure the mask assemblies with rubber bands against uncoiling 
(preferable by a second person). Disconnect the mask lanyards (remain attached 
to the release pin) at the mask assemblies. 
(3) Remove the manifold together with mask hoses from the oxygen generator, cut 
the mask hoses from the manifold fittings. Discard the manifold. 
(4) Install the mask hoses to the fittings of a new manifold, install the manifold back to 
the oxygen generator.  
(5) Connect the mask lanyards to the mask assemblies. 
Repack the oxygen mask assemblies and close the door assy.   
(6) Do a manual door release test with test button in test position. 
 
For 22C22 – 0100 Series Oxygen Container 
This Service Bulletin is recommended to be performed in a workshop within the following 
approximate man-hours and elapsed time of 0.3 hours. 
NOTE: The man-hours and elapsed time do not include the removal/installation of the 
oxygen generator from/to the aircraft. 
(7) Open the door of the oxygen container, secure the mask assemblies with a rubber 
band, remove the oxygen generator together with the mask assemblies.

### Page 5

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 5 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
Disconnect the mask lanyards (remain attached to the release pin) at the mask 
assemblies 
(8) Remove the manifold together with mask hoses from the oxygen generator, cut 
the mask hoses from the manifold fittings. Discard the manifold. 
(9) Install the mask hoses to the fittings of a new manifold, install the manifold back to 
the oxygen generator.  
(10) Connect the mask lanyards to the mask assemblies. 
(11) Install the oxygen generator together with the mask assemblies back into the 
container. Repack the oxygen mask assemblies and close the door assy.  
(12) Do a manual door release test with test button in test position. 
 
H. WEIGHT AND BALANCE 
Weight:  not affected 
Balance: not affected 
 
J. REFERENCE 
This Service Bulletin is covered by Aircraft Inspection Service Bulletin Number  
A320-35-1047.  
CMM 35-22-25, (D1379) 
 
K. PUBLICATION AFFECTED 
CMM 35-22-25 (D1379) 
 
L. INTERCHANGEABILITY OF PARTS 
Refer to aircraft Service Bulletin No. 35-1047.

### Page 6

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 6 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
2. MATERIAL INFORMATION 
A. MATERIAL COST AND AVAILABILITY 
The cost of the Service Bulletin application are:        Free of Charge (FOC) 
For part procurements and warranty claim please contact: 
B/E Aerospace Systems GmbH 
Revalstrasse 1 
23560 Lübeck 
GERMANY 
 
Cage Code :  D1379 
 
Tel: (49) 451 4093-2976 
Fax: (49) 451 4093-4488 
e-mail: dieter_heins@beaerospace-systems.com 
 
 
B. INDUSTRIE SUPPORT INFORMATION 
NOTE: It is recommended that completion of this Service Bulletin be performed by 
authorized personnel only. It is recommended to perform this SB work in a 
workshop. Customized solutions may be negotiated separately.

### Page 7

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 7 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
C. MATERIAL NECESSARY FOR EACH OXYGEN CONTAINER ASSY 
The following Table shows all parts necessary to perform this SB work  
New PNR Keyword Old PNR 
Type of 
Container / 
Qty/Container Price 
22C15 22C22 
E63282-01 Manifold 2P E63282-01  1 FOC 
E63281-00 Manifold 2P E63281-00 1  FOC 
E71070-00 Pin,Grooved  (as required) E71070-00 2 2 FOC 
E20274-06 O-Ring E20274-06 1 1 FOC 
E61063-00 Disc, Spring loaded (as required) E61063-00 1 1 FOC 
E63047-00 Cable Tie E63047-00  1 FOC 
 
 
D. TOOLING – PRICE AND AVAILABILITY 
Special Tools Part Number Price /  Availability Source  
Manual Release Tool E60100-00  (D1379) 
Rubber bands  - - - - Local Purchase 
Mask Hose Assembly Tool 2231070  (D1379) 
Cutter Knife, Hose Cutter - - - - Local Purchase 
Removal Tool (removal of grooved pins) E61088-00  (D1379) 
Marker, permanent (green color) STABILO - - Local Purchase 
Pointed Pliers  - - Local Purchase 
Pliers (Warning Flag installation) E71516-00  (D1379) 
Warning Flag Assembly (as required) E71401-00  (D1379) 
Cable Tie Pliers 2231453  (D1379)

### Page 8

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 8 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
3. ACCOMPLISHMENT INSTRUCTIONS 
A. GENERAL 
General service information is given within the component maintenance manuals.  
WARNING: STRICTLY OBEY THE PROCEDURES FOR THE USE OF OXYGEN 
EQUIPMENT. DO NOT USE ANY OIL, GREASE, HYDRO CARBONS 
OR OTHER LUBRICANTS MADE FROM PETROLEUM IN THE 
WORK AREA OF THIS OXYGEN EQUIPMENT. THIS CAN CAUSE A 
DANGEROUS FIRE HAZARD. 
B. LIST OF MATERIALS 
New PNR Keyword Old PNR 
Type of 
Container / 
Qty/Container 
Inst/Disp 
22C15 22C22  
E63282-01 Manifold 2P E63282-01  1 Replaced 
E63281-00 Manifold 2P E63281-00 1  Replaced 
E71070-00 Pin,Grooved (as required) E71070-00 2 2 On Condition 
E20274-06 O-Ring E20274-06 1 1 Replaced 
E61063-00 
Disc, Spring 
loaded  
(as required) 
E61063-00 1 1 On Condition 
E63047-00 Cable Tie E63047-00  1 FOC

### Page 9

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 9 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
 
Special Tools Part Number Source  
Manual Release Tool E60100-00 (D1379) 
Rubber bands  - - Local Purchase 
Mask Hose Assembly Tool 2231070 (D1379) 
Cutter Knife, Hose Cutter - - Local Purchase 
Pin Removal Tool ( for grooved pins) E61088-00 (D1379) 
Marker, permanent (green color) STABILO Local Purchase 
Pointed Pliers - - Local Purchase 
Cable Tie Pliers 2231453 (D1379) 
Pliers (Warning Flag installation) E71516-00 (D1379) 
Warning Flag Assembly (as required) E71401-00 (D1379)

### Page 10

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 10 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
FOR 22C15-0100 CONTAINER ASSEMBLIES  (SB ACCOMPLISHMENT ON 
AIRCRAFT OR IN THE WORKSHOP) 
C. DISASSEMBLY 
WARNING: STRICTLY OBEY THE PROCEDURES FOR USE OF OXYGEN 
EQUIPMENT. DO NOT USE ANY OIL, GREASE OR OTHER 
LUBRICANTS MADE FROM PETROL IN THE WORK AREA OF THIS 
OXYGEN EQUIPMENT. THIS CAN CAUSE A DANGEROUS FIRE 
HAZARD RESULTING IN SERIOUS PERSONAL INJURY OR DEATH. 
CAUTION: IN GENERAL THE WORK ON OXYGEN EQUIPMENT REQUIRES THE 
USE OF LINT -FREE GLOVES. HOWEVER  SOME STEPS OF THIS 
REWORK MAY BE HINDER ED WHEN WEARING GLOV ES. 
THEREFORE THIS REWOR K IS RECOMMENDED TO BE DONE WITH 
DRY AND CLEAN FINGERS. ENSURE YOUR FINGERS ARE DRY AND 
CLEAN. 
(1)  Open the Door Assy as follows: 
CAUTION: EXERCISE CAUTION WITH THE CONTAINER DOOR. IT IS SPRING-
LOADED, CAN SNAP AWAY AND PUSH OUT THE MASK 
ASSEMBLIES. SET THE TEST LEVER INTO TEST POSITION  (HOLD 
THE DOOR BY HAND) WHEN YOU RELEASE IT WITH THE RELEASE 
TOOL PNR E60100-00. AFTER RELEASE LET THE DOOR CAREFULLY 
AND SLOWLY MOVE INTO ITS FULLY OPEN POSITION. 
CAUTION: EXERCISE CAUTION WITH THE MASK LANYARDS WHEN YOU OPEN 
THE DOOR ASSY, AN ACCIDENTAL PULL CAN REMOVE THE 
RELEASE PIN FROM THE OXYGEN GENERATOR ASSY AND START 
THE FLOW OF OXYGEN THAT CANNOT BE STOPPED. 
(a) Set the test button into the test position.  
(b) Put the manual release tool PNR E60100-00 into the release access hole 
of the door assembly. Unlock the door latch with a slight push. The door 
must open a few degrees (See Figure 1).  
(c) Remove the manual release tool PNR E60100-00 from the manual 
release access hole.  
CAUTION: EXERCISE CAUTION WITH  THE MASK ASSEMBLIES. WHEN 
YOU OPEN THE CONTAINER DOOR THE MASKS WILL FALL 
OUT AND BECOME UNCOILED. 
PREFERABLY OPEN THE DOOR WITH A SECOND PERSON 
THAT KEEPS THE MASKS INSIDE THE CONTAINER.

### Page 11

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 11 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
(d) Hold the door in position by hand and reset the test button back to its 
operational position. Carefully let the door move into its fully open position 
(min. 180°). Make sure the masks do not become uncoiled. 
 
Figure 1 
(e) Put a rubber band around the packed mask assemblies. This makes sure 
the mask tubes do not become uncoiled and the breathing bags are held 
in position within the mask facepiece (See Figure 2). 
 
Figure 2 
CAUTION: EXERCISE CAUTION WITH THE MASK LANYARDS WHEN 
YOU DISCONNECT THEM FROM THE SNAP HOOKS OF THE 
MASKS. AN ACCIDENTAL PULL CAN REMOVE THE RELEASE 
PIN FROM THE OXYGEN GENERATOR ASSY AND START 
THE FLOW OF OXYGEN THAT CANNOT BE STOPPED. 
Rubber Band

### Page 12

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 12 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
(f) Disconnect the white mask lanyards from the masks.  
 
(3) Removal of the Manifold  
(a) Use the Pin Removal Tool PNR E61088-00 and carefully push the two 
grooved pins out until you can catch them with a pointed plier as shown 
on Figure 3. Then fully pull out the grooved pins from the manifold. 
 
Figure 3 
(b) Carefully remove (by slightly turning and pulling) the manifold together 
with the mask hoses from the oxygen generator. 
(c) Remove the disc together with the compression spring from the manifold 
(See Figure 4). 
Pin Removal 
Tool E61088-00 
Manifold Mask Hose

### Page 13

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 13 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
 
Figure 4 
(d) Use a Hose Cutter and cut the mask hoses at the fitting end (maximum 
distance of 2 mm to the fitting end) of the manifold (See Figure 5). 
CAUTION: ENSURE THAT THE REMAINING MASK HOSES ARE CLEAN 
FROM ANY ABRASION. REMOVE ANY ABRASION IF 
REQUIRED.  
 
 
Figure 5 
(e) Discard the manifold. 
(f) Remove the O-ring PNR E20274-06 from the first groove of the oxygen 
generator outlet port. Discard the O-ring. (See Figure 6) 
Hose Cutter 
Mask Hose  
Manifold 
Manifold 
Compression 
Spring 
Disc  
Silicone Ring

### Page 14

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 14 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
 
Figure 6 
 
O-ring 
E20274-06 
O-ring 
location: - 
first groove

### Page 15

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 15 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
FOR 22C15-0100 CONTAINER ASSEMBLIES (SB ACCOMPLISHMENT ON 
AIRCRAFT OR IN THE WORKSHOP) 
D. ASSEMBLY 
WARNING: STRICTLY OBEY THE PROCEDURES FOR USE OF OXYGEN 
EQUIPMENT. DO NOT USE ANY OIL, GREASE OR OTHER 
LUBRICANTS MADE FROM PETROL IN THE WORK AREA OF THIS 
OXYGEN EQUIPMENT. THIS CAN CAUSE A DANGEROUS FIRE 
HAZARD RESULTING IN SERIOUS PERSONAL INJURY OR DEATH. 
CAUTION: IN GENERAL THE WORK ON OXYGEN EQUIPMENT REQUIRES THE 
USE OF LINT -FREE GLOVES. HOWEVER  SOME STEPS OF THIS 
REWORK MAY BE HINDER ED WHEN WEARING GLOV ES. 
THEREFORE THIS REWOR K IS RECOMMENDED TO BE DONE WITH 
DRY AND CLEAN FINGER S. ENSURE YOUR FINGE RS ARE DRY AND 
CLEAN. 
(1)  Installation of the Manifold 
(a) Put a new O-ring in the first groove of the oxygen generator outlet port 
(See Figures 6 and 7). 
 
Figure 7 
CAUTION: ALWAYS USE A NEW MANIFOLD. A DEFECTIVE MANIFOLD 
MAKES THE OXYGEN GENERATOR UNSERVICEABLE. 
(b) If the used manifold has free flow and no damage, you can use it again.  
CAUTION: ENSURE THAT THE MANI FOLD IS EQUIPPED WIT H A BLUE SILICON 
RING USED AS A SAFETY RELIEF VALVE AS SHOWN IN FIGURE 4. 
Outlet port 
O-ring 
E20274-06

### Page 16

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 16 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
 
(c) Move the mask hoses over the cylindrical part of the manifold fitting as 
shown on Figure 8. 
 
Figure 8 
(d) Put the manifold together with the mask hoses on the Mask Hose 
Assembly Tool PNR. 2231070 . 
(e) Moderately operate the levers of the Mask Hose Assembly Tool PNR. 
2231070 and move the mask hoses on the fittings of the manifold until the 
tube touches the manifold housing as shown on Figure 9. Do not use 
excessive force when pushing the hoses onto the fitting as this ma y 
damage the manifold or the Mask Hose Assembly Tool. 
Then remove the manifold from the Assembly Tool. 
 
Figure 9 
(f) If necessary, use a new spring loaded disc PNR E61063-00. 
Mask Hose  
Manifold 
Mask Hose  
Manifold Mask Hose Assembly Tool PNR. 2231070

### Page 17

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 17 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
CAUTION: MAKE SURE THE SPRING LOADED DISC PNR E61063-00 HAS 
THE CORRECT POSITION. THE DISC MUST BE INSTALLED 
WITH THE COMPRESSION SPRING FIRST INTO THE 
MANIFOLD. IF THE DISC HAS NOT THE CORRECT POSITION 
THE OXYGEN GENERATOR IS NOT SERVICEABLE. 
(g) Put the assembled disc with the compression spring first into the manifold. 
(See Figures 4 and 10). 
 
Figure 10 
CAUTION: DO NOT APPLY UNCONTROLLED FORCE TO THE MANIFOLD 
DURING INSTALLATION AND EXERCISE CAUTION WITH  THE 
O-RING PNR E20274-06. TOO MUCH FORCE CAN CAUSE 
DAMAGE TO THE O-RING. ENSURE THAT THE GROOVED 
PINS ARE IN THE CORRESPONDING RECESS OF THE 
GENERATOR OUTLET. THE GROOVED PINS MUST NOT BE 
PUSHED INTO THE O-RING RECESS. A DEFECTIVE O-RING 
MAKES THE OXYGEN GENERATOR UNSERVICEABLE. 
(h) Carefully install the assembled manifold on the generator outlet port. Do 
this by slightly turning and pushing (See Figure 11). Make sure you do not 
damage the O-ring PNR E20274-06. 
Compression 
Spring 
Disc

### Page 18

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 18 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
 
Figure 11 
(i) Attach the manifold to the generator outlet port with two grooved pins 
PNR E71070-00.  
(2)  Final Assembly 
CAUTION: EXERCISE CAUTION WITH THE MASK LANYARDS WHEN 
YOU CONNECT THEM TO THE SNAP HOOKS OF THE 
MASKS. AN ACCIDENTAL PULL CAN REMOVE THE RELEASE 
PIN FROM THE OXYGEN GENERATOR ASSY AND START 
THE FLOW OF OXYGEN AND MASK SUPPLY TUBES GOES 
OVER THE TOP SIDE OF THE EJECTOR CRADLE.  
IF THE ROUTING OF THE LANYARDS AND MASK SUPPLY 
TUBES GOES BELOW THE EJECTOR CRADLE THE 
CONTAINER IS NOT SERVICEABLE. 
(a) Use the pointed pliers to connect the mask lanyards to the snap hooks of 
the mask. Make sure you connect only one lanyard to each snap hook 
(See Figure 12) and the lanyard route goes over the top side of the ejector 
cradle.

### Page 19

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 19 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
 
Figure 12 
(b) Remove the rubber bands from the masks.  
(c) Restore the masks in the oxygen container assembly (preferably with a 
second person) as shown on the mask installation instruction label in the 
inside of the container door.  
CAUTION: MAKE SURE THAT NO ITEMS ARE BETWEEN THE DOOR 
AND THE CONTAINER BEFORE YOU CLOSE THE DOOR. DO 
NOT APPLY UNCONTROLLED FORCE TO THE DOOR 
DURING CLOSING. YOU CAN CAUSE DAMAGE TO THE 
DOOR. A DEFECTIVE DOOR MAKES THE CONTAINER 
UNSERVICEABLE. 
CAUTION: MAKE SURE THE ROUTING OF LANYARDS AND MASK 
SUPPLY TUBES GOES OVER THE TOP SIDE OF THE 
EJECTOR CRADLE.  
IF THE ROUTING OF THE LANYARDS AND MASK SUPPLY 
TUBES GOES BELOW THE EJECTOR CRADLE THE 
CONTAINER IS NOT SERVICEABLE. 
(d) Push the door down at its hinge side first until the sliding hinges are 
locked (small click).  
(e) Set the door in closed position and push it tightly and gradually down on 
both sides (in the area of the locking hooks) until it is safely locked by the 
locking hooks with a click.  
(f) Push the right hand side to set test button into the test position. 
(g) Put the manual release tool PNR E60100 into the release access hole of 
the door. Unlock the door latch with a slight push. The door must open a 
few degrees and stops at the test position (held by the hook of the test 
button). 
Pointed Pliers 
Snap Hook 
Mask 
Lanyard

### Page 20

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 20 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
(h) Use a STABILO permanent marker and make a green dot on the inside of 
the test button as shown on Figure 13. This dot shows that this Service 
Bulletin has been successfully accomplished on the oxygen container. 
 
Figure 13 
(i) Push tightly and equally on both sides of the door until it locks at both 
locking hooks with a click.  
Green Dot 
Test Button 
in test 
position

### Page 21

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 21 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
FOR 22C22 – 0100 CONTAINER ASSEMBLIES (SB ACCOMPLISHMENT IN A 
WORK-SHOP) 
E. DISASSEMBLY 
WARNING: STRICTLY OBEY THE PROCEDURES FOR USE  OF OXYGEN 
EQUIPMENT. DO NOT USE ANY OIL, GREASE OR OTHER 
LUBRICANTS MADE FROM PETROL IN THE WORK AREA OF THIS 
OXYGEN EQUIPMENT. THIS CAN CAUSE A DANGEROUS FIRE 
HAZARD RESULTING IN SERIOUS PERSONAL INJURY OR DEATH. 
CAUTION: IN GENERAL THE WORK ON OXYGEN EQ UIPMENT REQUIRES THE  
USE OF LINT -FREE GLOVES. HOWEVER  SOME STEPS OF THIS 
REWORK M AY BE HINDERED WHEN W EARING GLOVES. 
THEREFORE THIS REWOR K IS RECOMMENDED TO BE DONE WITH 
DRY AND CLEAN FINGER S. ENSURE YOUR FINGE RS ARE DRY AND 
CLEAN. 
(1)  Put the oxygen container on a soft, clean and flat surface so that the door assy 
shows face up and the test button is in front of you. 
(2)  Open the Door Assy as follows: 
CAUTION: EXERCISE CAUTION WITH THE CONTAINER DOOR. IT IS SPRING-
LOADED, CAN SNAP AWAY AND PUSH OUT THE MASK 
ASSEMBLIES. HOLD THE DOOR DOWN BY HAND (OR SET THE TEST 
LEVER INTO TEST POSITION) WHEN YOU RELEASE IT WITH THE 
RELEASE TOOL PNR E60100-00. AFTER RELEASE LET THE DOOR 
CAREFULLY AND SLOWLY MOVE INTO ITS FULLY OPEN POSITION. 
CAUTION: EXERCISE CAUTION WITH THE MASK LANYARDS WHEN YOU OPEN 
THE DOOR ASSY, AN ACCIDENTAL PULL CAN REMOVE THE 
RELEASE PIN FROM THE OXYGEN GENERATOR ASSY AND START 
THE FLOW OF OXYGEN THAT CANNOT BE STOPPED. 
(a) Set the test button into the test position.  
(b) Put the manual release tool PNR E60100-00 into the release access hole 
of the door assembly. Unlock the door latch with a slight push (See Figure 
14). The door must open a few degrees.  
(c) Remove the manual release tool PNR E60100-00 from the manual 
release access hole.  
CAUTION: EXERCISE CAUTION WITH THE MASK ASSEMBLIES. WHEN 
YOU OPEN THE CONTAINER DOOR THE MASKS WILL FALL 
OUT AND BECOME UNCOILED. 
PREFERABLY OPEN THE DOOR WITH A SECOND PERSON 
THAT KEEPS THE MASKS INSIDE THE CONTAINER.

### Page 22

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 22 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
(d) Hold the door down by hand and reset the test button back to its 
operational position. Carefully let the door move into its fully open position 
(min. 180°). Make sure the masks do not become uncoiled. 
 
Figure 14 
(e) Put a rubber band around the packed mask assemblies. This makes sure 
the mask tubes do not become uncoiled and the breathing bags remain in 
position within the mask facepiece (See Figure15). 
 
Figure 15 
CAUTION: EXERCISE CAUTION WITH THE MASK LANYARDS WHEN 
YOU DISCONNECT THEM FROM THE SNAP HOOKS OF THE 
MASKS. AN ACCIDENTAL PULL CAN REMOVE THE RELEASE 
PIN FROM THE OXYGEN GENERATOR ASSY AND START 
THE FLOW OF OXYGEN THAT CANNOT BE STOPPED. 
Rubber Band

### Page 23

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 23 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
(f) Disconnect the white mask lanyards from the snap hooks of the masks.  
(g) Carefully put the mask lanyards over the side wall to the outside of the 
container. Make sure you do not pull at the lanyards they are connected to 
the release pin (See CAUTION above Step (f)). 
(h) Remove the masks from the ejector cradle of the door and put them near 
to the container on a clean surface (See Figure 16).  
(3)  Removal of the Oxygen Generator from the Container (See Figure 16) 
(a) Pull the ejector cradle of the door loose from the hook fastener of the 
container (Velcro connection). 
 
Figure 16 (15 Min. Unit shown)

### Page 24

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 24 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
(b) Loosen the generator mounting clamp. 
(c) Hold the generator mounting clamp back. Then carefully lift the oxygen 
generator together with the mask hoses from the container. Put the parts 
near the container on a dry, clean (free of oil) surface. 
(d) Use pliers flag E71516-00 to install the WARNING flag assembly on the 
oxygen generator starter side if required (See figure 17). 
 
Figure 17 
(4)  Removal of the Manifold from the Oxygen Generator 
(a) Use the Pin Removal Tool PNR E61088-00 and carefully push the two 
grooved pins out until you can catch them with a pointed plier as shown 
on Figure 18. Then fully pull out the grooved pins from the manifold.

### Page 25

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 25 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
 
Figure 18 (15 Min. Unit shown) 
(b) Very carefully remove (by slightly turning and pulling) the manifold 
together with the mask hoses from the oxygen generator. 
(c) Remove the disc PNR E60061-00 together with the compression spring 
PNR E61062-00 from the manifold (See Figure 19). 
 
Figure 19  
(d) Use a Hose Cutter and cut the mask hoses at the fitting end (maximum 
distance of 2 mm to the fitting end) of the manifold (See Figure 20). 
Manifold 
Compression 
Spring 
Disc  
Pin Removal 
Tool E61088-00 
Manifold Mask Hose  
Silicone Ring

### Page 26

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 26 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
 
Figure 20 
CAUTION: ENSURE THAT THE REMAINING MASK HOSES ARE CLEAN 
FROM ANY ABRASION. REMOVE ANY ABRASION IF 
REQUIRED. 
(e) Visually check the mask hoses for silicon abrasion (chips). Remove any 
abrasion if required. 
(f) Discard the manifold. 
(g) Remove the O-ring PNR E20274-06 from the first groove of the oxygen 
generator outlet port. Discard the O-ring. (See Figure 21) 
 
Hose Cutter 
Mask Hose  
Manifold

### Page 27

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 27 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
 
Figure 21 (15 Min. Unit shown) 
O-ring 
E20274-06 
O-ring 
location: - 
first groove

### Page 28

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 28 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
F. ASSEMBLY  
WARNING: STRICTLY OBEY THE PROCEDURES FOR USE OF OXYGEN 
EQUIPMENT. DO NOT USE ANY OIL, GREA SE OR OTHER 
LUBRICANTS MADE FROM PETROL IN THE WORK AREA OF THIS 
OXYGEN EQUIPMENT. THIS CAN CAUSE A DANGEROUS FIRE 
HAZARD RESULTING IN SERIOUS PERSONAL INJURY OR DEATH. 
CAUTION: IN GENERAL THE WORK ON OXYGEN EQUIPMENT REQUIRES THE 
USE OF LINT -FREE GLOVES. HOWEVER SOME STEPS O F THIS 
REWORK M AY BE HINDERED WHEN W EARING GLOVES. 
THEREFORE THIS REWOR K IS RECOMMENDED TO BE DONE WITH 
DRY AND CLEAN FINGER S. ENSURE YOUR FINGE RS ARE DRY AND 
CLEAN. 
(1)  Installation of the Manifold 
(a) Put a new O-ring in the first groove of the oxygen generator outlet port 
(See Figures 21 and 22). 
 
Figure 22 (15 Min. Unit shown) 
CAUTION: IF YOU ARE NOT SURE THE MANIFOLD IS SERVICEABLE OR 
NOT, ALWAYS USE A NEW MANIFOLD. A DEFECTIVE 
MANIFOLD MAKES THE OXYGEN GENERATOR 
UNSERVICEABLE. 
(b) If the used manifold has free flow and no damage, you can use it again.  
CAUTION: ENSURE THAT THE MANIFOLD IS EQUIPPED WITH A 
BLUE SILICON RING USED AS A SAFETY RELIEF VALVE 
AS SHOWN IN FIGURE 4. 
(c) Move the mask hoses over the recessed part of the manifold fitting as 
shown on Figure 23. 
Outlet port 
O-ring 
E20274-06

### Page 29

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 29 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
 
Figure 23 
(d) Put the manifold together with the mask hoses on the Mask Hose 
Assembly Tool PNR. 2231070 . 
 
Figure 24 
 
 
Mask Hose  
Manifold 
Fitting 
Mask Hoses  
Mask Hose Assembly 
Tool PNR. 2231070

### Page 30

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 30 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
(e) Moderately operate the levers of the Mask Hose Assembly Tool PNR. 
2231070 and move the mask hoses on the fittings of the manifold until the 
tube touches the manifold housing as shown on Figure 25. Do not use 
excessive force when pushing the hoses onto the fitting as this may 
damage the manifold or the Mask Hose Assembly Tool. 
Then remove the manifold from the Assembly Tool. 
 
Figure 25 
(f) Use the Cable Tie Pliers 2231453 (must be adjusted to a torque value of 
120 N +/-10 N) and install the cable tie(s) PNR E63047-00 on the 
manifold fittings as shown on Figure 26 to 27. 
 
Figure 26 
Mask Hose Assembly 
Tool PNR. 2231070 
Cable Tie PNR 
E60047-00

### Page 31

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 31 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
 
Figure 27 
 
(g) If necessary, use a new spring loaded disc PNR E61063-00 
CAUTION: MAKE SURE THE SPRING LOADED DISC PNR E61063-00 HAS 
THE CORRECT POSITION. THE DISC MUST BE INSTALLED 
WITH THE COMPRESSION SPRING FIRST INTO THE 
MANIFOLD. IF THE DISC HAS NOT THE CORRECT POSITION 
THE OXYGEN GENERATOR IS NOT SERVICEABLE. 
(h) Put the assembled disc with the compression spring first into the manifold. 
(See Figure 28). 
Cable Tie Pliers 
PNR 2231453

### Page 32

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 32 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
 
Figure 28 
CAUTION: DO NOT APPLY UNCONTROLLED FORCE TO THE MANIFOLD 
DURING INSTALLATION AND EXERCISE CAUTION WITH  THE 
O-RING PNR E20274-06. TOO MUCH FORCE CAN CAUSE 
DAMAGE TO THE O-RING. ENSURE THAT THE GROOVED 
PINS ARE IN THE CORRESPONDING RECESS OF THE 
GENERATOR OUTLET. THE GROOVED PINS MUST NOT BE 
PUSHED INTO THE O-RING RECESS. A DEFECTIVE O-RING 
MAKES THE OXYGEN GENERATOR UNSERVICEABLE. 
(i) Carefully install the assembled manifold on the generator outlet port. Do 
this by slightly turning and pushing (See Figure 29). Make sure you do 
cause damage to the O-ring PNR E20274-06. 
 
Figure 29 
Compression 
Spring 
Disc PNR 
E61062-00 
Manifold

### Page 33

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 33 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
(j) Attach the manifold to the generator outlet port with two grooved pins 
PNR E71070-00.  
(2)  Installation of the Oxygen Generator into the Container (See Figure 30) 
CAUTION: EXERCISE CAUTION WITH THE MASK LANYARDS DURING 
INSTALLATION OF THE OXYGEN GENERATOR.  
AN ACCIDENTAL PULL CAN REMOVE THE RELEASE PIN 
FROM THE OXYGEN GENERATOR ASSY AND START THE 
FLOW OF OXYGEN THAT CANNOT BE STOPPED. 
(a) Put the oxygen generator between the arms of the generator mounting 
clamp into the container assembly (let the masks stay outside the 
container). Make sure the HOT label shows face up. 
(b) Put the mask lanyard ends temporarily over the side wall of the container.  
(c) Move the oxygen generator with the starter side (the end with the release 
pin tightly into the hole of the lanyard pad).

### Page 34

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 34 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
 
Figure 30 (15 Min. Unit shown) 
(d) Turn the clamp screw of the generator mounting clamp to rear side wall of 
the container as shown on Figure 30. 
(e) Attach the oxygen generator with the generator mounting clamp. Use an 
applicable torque wrench and tighten the clamp screw to a torque value of 
1,0 Nm (0.4426 ft./lbf). 
(f) Turn the release pin into a vertical position so that its eyelet shows face 
upward.

### Page 35

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 35 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
(3)  Final Assembly 
(a) Put the ejector cradle of the door over the oxygen generator. Press the 
loop strip of the ejector cradle on the hook fastener of the inner front side 
wall of the container (See Figure 31). 
 
Figure 31 
(b) Restore the masks in the oxygen container assembly as shown on the 
mask installation instruction label in the inside of the container door. 
CAUTION: EXERCISE CAUTION WITH THE MASK LANYARDS AND THE 
GENERATOR RELEASE LANYARD WHEN YOU CONNECT 
THEM TO THE SNAP HOOKS OF THE MASKS. AN 
ACCIDENTAL PULL CAN REMOVE THE RELEASE PIN FROM 
THE OXYGEN GENERATOR ASSY AND START THE FLOW OF 
OXYGEN THAT CANNOT BE STOPPED. 
CAUTION: MAKE SURE THE ROUTING OF LANYARDS AND MASK 
SUPPLY TUBES GOES OVER THE TOP SIDE OF THE 
EJECTOR CRADLE.  
IF THE ROUTING OF THE LANYARDS AND MASK SUPPLY 
TUBES GOES BELOW THE EJECTOR CRADLE THE 
CONTAINER IS NOT SERVICEABLE. 
(c) Use the pointed pliers to connect the white mask lanyards to the snap 
hooks of the masks. Make sure you connect only one lanyard to each 
snap hook (See Figure 32) and the lanyard route goes over the top side of 
the ejector cradle (See Figure 33).

### Page 36

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 36 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
 
Figure 32 
 
Figure 33 (15 Min. unit shown) 
Pointed Pliers 
Snap Hook 
Mask 
Lanyard

### Page 37

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 37 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
(d) Put the masks on the top side of the ejector cradle into the container. 
Make sure the route of the mask lanyards and mask supply tubes goes 
over the top side of the ejector cradle (See Figure 33). 
(e) Remove the rubber bands from the masks.   
(4)  Close the Door as follows 
(a) Look into the unit before you close the door. Make sure that: 
 
-   all rubber bands are removed from the masks. 
-   the mask assemblies, lanyards and mask supply tubes are installed on  
-   the top side of the ejector cradle, 
-   that none of the masks elastic head bands, oxygen supply tubes, nor 
    lanyards will be closed in the door, 
-   the eyelet of the release pin shows face upward. 
(b) Let the flag of the warning flag assy go out of the container at the starter 
side of the generator. Make sure that no lanyards or supply tubes lay on 
the warning flag. 
(c) Turn the container so that the door actuator is on the right and  the masks 
are in front of you. 
CAUTION: MAKE SURE THAT NO ITEMS ARE BETWEEN THE DOOR 
AND THE CONTAINER BEFORE YOU CLOSE THE DOOR.  
DO NOT APPLY UNCONTROLLED FORCE WHEN YOU CLOSE 
THE DOOR. YOU CAN CAUSE DAMAGE TO THE DOOR. A 
DEFECTIVE DOOR MAKES THE CONTAINER 
UNSERVICEABLE. 
(d) Set the door to a 90 degree vertical position and push the door down until 
the sliding hinges are locked (small click).  
(e) Carefully close the door and push it tightly and gradually down on both 
sides (in the area of the locking hooks) until it is safely locked by the two 
locking hooks  
(f) Push the right hand side to set test button into the test position. 
(g) Put the manual release tool PNR E60100-00 into the release access hole 
of the door. Unlock the door latch with a slight push. The door must open 
a few degrees and stops at the test position (held by the hook of the test 
button). 
(h) Use a STABILO permanent marker and make a green dot on the inside of 
the test button as shown on Figure 34. This dot shows that this Service 
Bulletin has been successfully accomplished on the oxygen container.

### Page 38

SERVICE BULLETIN 
22CXX-0100-35-003 
 
 
Original Issue 
MAR/17/2011 
Page 38 of 38 
Rev.: 2 
Jul/10/2014 SB 22CXX-0100-35-003  
 
 
Figure 34 
(i) Push tightly and equally on both sides of the door until it locks at both 
latch hooks  
 
Green Dot 
Test Button 
in test 
position

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.