# B/E Aerospace Service Bulletin 174080-35-02

Copy: Revision 1 ("B/E Aerospace - Service Bulletin"), 7 pages: PDF https://openairdocs.org/files/sha256/07/9c/079c2514cc98785202dc0415a7c9ff3af7c6fcc1007fe6b4a82a9fc977b9ef9c; text https://openairdocs.org/service-documents/be-aerospace/sb-174080-35-02/file/079c2514cc98.md. Rights: © B/E Aerospace. Filed by the FAA in regulations.gov docket FAA-2011-0139, the docket of AD 2011-14-08. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [B/E Aerospace](https://openairdocs.org/service-documents/be-aerospace.md)
- Type: Service bulletin (Service Bulletin)
- Number: 174080-35-02
- Latest revision known: 174080-35-02, Revision 1 (OpenAirDocs)
- Page: https://openairdocs.org/service-documents/be-aerospace/sb-174080-35-02

## ADs that cite it (1) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2011-14-08](https://openairdocs.org/ad/2011-14-08.md), effective Aug 19, 2011: Revision 1

## Text (7 pages)

Rights: © B/E Aerospace. Filed by the FAA in regulations.gov docket FAA-2011-0139, the docket of AD 2011-14-08. Not covered by OpenAirDocs’ CC0 dedication. Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

SERVICE BULLETIN 
30 May 2008 
Rev. 1, 13 Apr 2010 Page 1 of 7 
174080-35-02 
The information disclosed herein was originated by and is the property of B/E Aerospace, Inc., and exc ept for 
rights expressly granted to the U.S. Government, B/E Aerospace, Inc. reserves all patent, proprietary, design, use, 
manufacturing, and reproduction rights thereto. 
OXYGEN - PASSENGER OXYGEN SYSTEM  
MASK IN-LINE FLOW INDICATOR REPLACEMENT 
I. Planning Information 
A. Effectivity 
This Service Bulletin applies to Airbus aircraft th at use passenger oxygen mask part numbers 
174080-XX, 174085-XX, 174095-XX, and 174098-XX manu factured on or after January 1, 2002 and 
before March 1, 2006. Table 1 below lists the effective B/E part numbers. This Service Bulletin applie s 
to spare masks in stores, as well as those installe d on aircraft. 
Table 1 
Effective Passenger Mask Part Numbers 
B. Reason 
Some existing flow indicators are vulnerable to fra cturing which causes parts of the indicator to 
separate. If this occurs, the oxygen cannot flow to  the user of the mask when needed during an 
emergency. 
B/E PART NUMBER 
174080-73 174085-96 174098-01 
174080-74 174085-97 174098-02 
174080-76 174085-98 174098-03 
174080-87 174095-1E 174098-04 
174080-96 174095-73 174098-05 
174080-97 174095-74 174098-06 
174080-98 174095-76 
174085-73 174095-87 
174085-74 174095-96 
174085-76 174095-97 
174085-87 174095-98

### Page 2

174080-35-02 30 May 2008 
Rev. 1, 13 Apr 2010 
B/E AEROSPACE 
Service Bulletin 
Page 2 of 7 
C. Description 
This Service Bulletin describes the optional replac ement of flow indicator part number 118023-02 with 
the improved flow indicator part number 118023-12. The improved flow indicator can be identified by 
the green marking (refer to Figure 1). 
The operator may purchase a replacement mask with t he improved flow indicator installed as an 
alternative to performing the modification covered by this Service Bulletin. 
Figure 1 
Flow Indicators 
D. Compliance 
Performance of this Service Bulletin is optional. 
E. Approval 
This Service Bulletin has been reviewed by Airbus a nd the FAA. 
F. Manpower 
Assuming access has been obtained to the unit, the following is an estimate to accomplish the 
modification: 
Verification:   .6 min. 
Disassembly:   .3 min. 
Assembly: 1.2 min. 
Testing:   .4 min. 
Cleaning:   .5 min. 
Total Modification:  3.0 min. 
G. Material - Price and Availability 
(1) Modification requires the following: 
Quantity Part Number Name 
1 118023-12 Flow Indicator

### Page 3

174080-35-02 30 May 2008 
Rev. 1, 13 Apr 2010 
B/E AEROSPACE 
Service Bulletin 
Page 3 of 7 
(2) Material may be obtained from: 
B/E Aerospace, Inc. 
Commercial Aircraft Products Group 
10800 Pflumm Road 
Lenexa, KS  66215 
TEL: (913) 338-9800 
FAX: (913) 469-8419 
(3) Delivery determined upon request. 
H. Tooling - Price and Availability 
Tubing Stretcher Tool part number 997300-00, availa ble from B/E Aerospace, Lenexa, KS (refer to 
Figure 2). 
I. Weight and Balance 
This modification will not affect the weight or bal ance. 
J. Electrical Load Data 
This modification will not affect electrical load d ata. 
K. Other Publications Affected 
Part Number CMM Number Dated 
174080-XX 35-20-96 2003/06/12 
174085-XX 35-24-02 2002/07/24 
174095-XX 35-24-04 2000/11/01 
II. Accomplishment Instructions 
A. Verification 
(1) Make sure the part number shown on the mask data  label is listed in Table 1. If the part number is 
not listed, no further action is required (refer to  Figure 3 for location of data label). 
(2) Make sure the date of manufacture shown on the m ask data label is on or after January 1, 2002 
and before March 1, 2006. If the date is outside th is range, no further action is required (refer to 
Figure 3 for location of data label). 
(3) Make sure the marking, "FLOW", on the flow indic ator is in black and the letter "W" does not appear 
on the right side of the mask data label (approximate location is shown in Figure 3). In the event the 
marking on the flow indicator is in green and the letter "W" is on the right side of the data label, flow 
indicator replacement has already been implemented.  No further action is required. 
B. Disassembly (refer to Figure 3) 
WARNING: THE USE OF OIL AND OTHER PETROLEUM BASE LUBRICANTS ON OXYGEN 
EQUIPMENT WILL CREATE A DANGEROUS FIRE HAZARD. 
CAUTION: THE WORK AREA MUST BE CLEAN AND FREE OF HYDROCARBON RESIDUE, OIL, 
OR OTHER PETROLEUM BASE LUBRICANTS.

### Page 4

174080-35-02 30 May 2008 
Rev. 1, 13 Apr 2010 
B/E AEROSPACE 
Service Bulletin 
Page 4 of 7 
CAUTION: ALL INSTRUMENTS, TOOLS, FIXTURES, TEST EQUIPMENT, A ND OTHER 
MATERIALS WHICH COME INTO CONTACT EITHER DIRECTLY O R INDIRECTLY 
WITH THE UNIT OR ITS PARTS SHOULD BE CLEAN AND FREE OF HYDROCARBON 
RESIDUE, OIL, OR OTHER PETROLEUM BASE LUBRICANTS. 
WARNING: BE CAREFUL TO CUT OFF ONLY A MINIMUM AMOUNT OF TUBING (1, 4). CUT OFF 
NO MORE THAN TWO INCHES OF TUBING FROM BOTH TUBES ( 1, 4) TOGETHER. 
(1) Cut the supply tube (4) loose from the flow indi cator (2). 
(2) Cut the flow indicator (2) loose from the mask b ag assembly tube (1). 
NOTE: Cut the tubing (1, 4) square so that the end is flat and perpendicular to the axis of the tube. 
C. Assembly (refer to Figure 3 unless otherwise stat ed) 
WARNING: THE USE OF OIL AND OTHER PETROLEUM BASE LUBRICANTS ON OXYGEN 
EQUIPMENT WILL CREATE A DANGEROUS FIRE HAZARD. 
CAUTION: THE WORK AREA MUST BE CLEAN AND FREE OF HYDROCARBON RESIDUE, OIL, 
OR OTHER PETROLEUM BASE LUBRICANTS. 
CAUTION: ALL INSTRUMENTS, TOOLS, FIXTURES, TEST EQUIPMENT, A ND OTHER 
MATERIALS WHICH COME INTO CONTACT EITHER DIRECTLY O R INDIRECTLY 
WITH THE UNIT OR ITS PARTS SHOULD BE CLEAN AND FREE OF HYDROCARBON 
RESIDUE, OIL, OR OTHER PETROLEUM BASE LUBRICANTS. 
WARNING: THE NEW FLOW INDICATOR (3) MUST BE INSTALLED SO THA T THE FLOW 
DIRECTION IS FROM THE SUPPLY TUBE (4) TOWARD THE MA SK BAG 
ASSEMBLY TUBE (1).  THE ARROW ON THE FLOW INDICATOR (3) SHOULD POINT 
TOWARDS THE BAG.  IF THE NEW FLOW INDICATOR (3) IS INSTALLED 
BACKWARDS, THE FLOW INDICATOR WILL NOT SHOW WHEN OX YGEN FLOWS 
TO THE MASK. 
CAUTION: THE SUPPLY TUBE (4) AND THE MASK BAG ASSEMBLY TUBE (1) ENDS SHOULD 
ALWAYS BE FULLY INSTALLED ON THE FLOW INDICATOR (3)  (UP TO THE 
SHOULDER OF THE FLOW INDICATOR). 
CAUTION: THE TUBING STRETCHER TOOL PART NUMBER 997300-00 MUS T BE SECURED 
TO A BENCH TOP BEFORE USE (REFER TO FIGURE 2). 
(1) Use the Tubing Stretcher Tool part number 997300 -00 (refer to Figure 2) to expand the inside 
diameter of the end of the mask bag assembly tube ( 1). 
CAUTION: DO NOT MAKE THE INSIDE DIAMETER OF THE MASK BAG ASS EMBLY TUBE (1) 
LARGER THAN THE DIAMETER NEEDED TO PUT THE TUBE OVER THE OUTSIDE 
OF THE FITTING OF THE NEW FLOW INDICATOR (3). DO NOT MAKE THE INSIDE 
DIAMETER OF THE MASK BAG ASSEMBLY TUBE (1) SO LARGE THAT THE TUBE 
SPLITS OR DISCOLORATION OF THE TUBE OCCURS. 
(2) Attach the prepared end of the mask bag assembly  tube (1) to the clear window end of the flow 
indicator (3). Slide the tubing on the open end of the flow indicator (3) until the mask bag assembly 
tube (1) end meets the shoulder of the flow indicat or (3).

### Page 5

174080-35-02 30 May 2008 
Rev. 1, 13 Apr 2010 
B/E AEROSPACE 
Service Bulletin 
Page 5 of 7 
CAUTION: WHILE PUTTING THE TUBE ON THE FLOW INDICATOR (3), D O NOT USE TOO 
MUCH FORCE THAT MAY DAMAGE THE FLOW INDICATOR (3). 
NOTE: Momentarily dipping the tube (1) end into denatured  alcohol or isopropyl alcohol 
(commercially available) will make it easier to slide the tube (1) on the flow indicator (3). 
(3) Use the Tubing Stretcher Tool part number 997300 -00 (refer to Figure 2) to expand the inside 
diameter of the end of the supply tube (4). 
CAUTION: DO NOT MAKE THE INSIDE DIAMETER OF THE SUPPLY TUBE (4) LARGER THAN 
THE DIAMETER NEEDED TO PUT THE TUBE OVER THE OUTSID E OF THE 
FITTING OF THE NEW FLOW INDICATOR (3). DO NOT MAKE THE INSIDE 
DIAMETER OF THE SUPPLY TUBE (4) SO LARGE THAT THE T UBE SPLITS OR 
DISCOLORATION OF THE TUBE OCCURS. 
(4) Attach the prepared end of the supply tube (4) o n the end of the flow indicator (3) having the green 
marking. Slide the tubing on the open end of the flow indicator (3) until the supply tube (4) end meets 
the shoulder of the flow indicator (3). 
CAUTION: WHILE PUTTING THE TUBE ON THE FLOW INDICATOR (3), D O NOT USE TOO 
MUCH FORCE THAT MAY DAMAGE THE FLOW INDICATOR (3). 
NOTE: Momentarily dipping the tube (4) end into denatured  alcohol or isopropyl alcohol 
(commercially available) will make it easier to slide the tube (4) on the flow indicator (3). 
(5) After the tubes (1, 4) have contracted around th e flow indicator (3), make sure the tubes (1, 4) ar e 
tight on the flow indicator (3). 
(6) Once the new flow indicator (3) is installed in the assembly, write on the data label on the bag 
assembly with permanent ink. Write the letter "W" o n the right side of the data label approximately 
as shown in Figure 3. 
Figure 2 
Tubing Stretcher Tool PN 997300-00

### Page 6 (OCR)

B/E AEROSPACE
Service Bulletin
OXYGEN MASK
B/E PN 174080 - XX REV X  WRITE A "W"
CUST.PN XXXXXX - XX  W -  WITH PERMANENT
TSO-C64 NAS1179-04172231  INK AFTER CHANGE
MFG DATE MM-DD-YY  OF FLOW INDICATOR  Mask Bag
ELASTOMER CURE DATE XQYY
B/E AEROSPACE, INC.
LENEXA, KANSAS
2, PN 118023-02
Mask Cup
MARKING IN GREEN
3, PN 118023-12, REPLACES ITEM 2
NOTE: Not shown to scale.
Figure 3
Passenger Oxygen Mask
D. Testing (refer to Figure 3)
WARNING:  IF THE NEW FLOW INDICATOR (3) IS INSTALLED BACKWARDS, THE FLOW
INDICATOR WILL NOT SHOW WHEN OXYGEN FLOWS TO THE MASK.
(1) Look for the directional arrow that has been stamped on the side of the flow indicator (3) body. The
flow directional arrow must point toward the oxygen mask bag assembly.
(2) Make sure the directional arrow and markings are in green, showing that the replacement has been
implemented.
(3) Make sure the letter "W" is on the right side of the data label (approximate location is shown in
Figure 3), showing that the replacement has been implemented.
30 May 2008  174080-35-02
Rev. 1, 13 Apr 2010  Page 6 of 7

### Page 7

174080-35-02 30 May 2008 
Rev. 1, 13 Apr 2010 
B/E AEROSPACE 
Service Bulletin 
Page 7 of 7 
E. Cleaning 
WARNING: THE USE OF OIL AND OTHER PETROLEUM BASE LUBRICANTS ON OXYGEN 
EQUIPMENT WILL CREATE A DANGEROUS FIRE HAZARD. 
CAUTION: THE WORK AREA MUST BE CLEAN AND FREE OF HYDROCARBON RESIDUE, OIL, 
OR OTHER PETROLEUM BASE LUBRICANTS. 
CAUTION: DO NOT LET DENATURED ALCOHOL TOUCH THE MASK BAG AS IT MAY REMOVE 
INK ON THE BAG. 
(1) Use a clean lint-free cloth moistened with denat ured alcohol to lightly wipe down the mask cup and 
tubing.  Do not allow cleaning solution to enter tu be or reservoir bag. 
(2) Denatured alcohol can be used to remove stains o r contamination. 
(3) Allow the mask assembly to fully dry after clean ing. 
III. Material Information 
Table 2 
Materials List 
FIG. 
NO. 
ITEM 
NO. NEW PART NO. QTY DESCRIPTION OLD PART NO. 
INSTRUCTIONS/ 
DISPOSITION 
2,3 1 MASK BAG ASSY 
TUBING 
820502-00 
820770-00 
(174080-XX) 
(174085-XX) 
(174095-XX) 
(174098-XX) 
REUSE 
1,3 2 1 FLOW INDICATOR 118023-02 DISCARD 
1,3 3 118023-12 1 FLOW INDICATOR NEW 
2,3 4 SUPPLY TUBING 632080-12 
820502-00 
076112-00 
(174080-XX) 
(174085-XX) 
(174098-XX) 
(174095-XX) 
REUSE

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.