### Page 1

ALERT SERVICE BULLETIN 
 
DATE  
REVISION NOTICE 
 
 
 
A Subsidiary of Textron Inc. 
Nov 14, 2005 
 
 
 
 
 
 
TO:  All Owners/Operators of Bell 427 Helicopters 
 
SUBJECT: REVISION “A” TO ALERT SERVICE BULLETIN 427-05-12: 
 CLEVIS ASSEMBLY-HYDRAULIC SERVO ASSEMBLY PART NUMBER 
41011300 AND 41011700  
 
 
Revision “A” to this Alert Service Bulletin introduces the rewritten Hydraulic Research 
Textron Bulletin.  Included in the rewritten bulletin are the following changes: 
 
• The HR Textron Customer Service telephone number phone number, is added 
in Section 1, Step F. 
• The compliance in Section 2, Step A, is changed. 
• The inspection criteria are clarified in Section 2. 
• HR Textron-Authorized Service Centers telephone and fax number are added 
in Table 1. 
• A better graphic view of the proper installation is shown in Figure 1. 
 
 
 
 
 
AN APPROPRIATE ENTRY SHOULD BE MADE IN THE AIRCRAFT LOGBOOK UPON ACCOMPLISHMENT 
IF OWNERSHIP OF AIRCRAFT HAS CHANGED PLEASE FORWARD TO NEW OWNER

### Page 2

NO. 
  
DATE   
PAGE  
    DATE  
    REV  
 
ALERT SERVICE BULLETIN 
 
 
 
A Subsidiary of Textron Inc. 
AN APPROPRIATE ENTRY SHOULD BE MADE IN THE AIRCRAFT LOGBOOK UPON ACCOMPLISHMENT 
IF OWNERSHIP OF AIRCRAFT HAS CHANGED PLEASE FORWARD TO NEW OWNER 
427-05-12 
Nov 14, 2005 Oct 12, 2005 
A 1  
 
 
 
 
MODEL AFFECTED:  427 
 
 
 
SUBJECT: CLEVIS ASSEMBLY HYDRAUL IC SERVO  
ASSEMBLY, PART  NUMBER 410113 00 AND 
41011700   
 
 
 
 
HELICOPTERS AFFECTED: Model 427 helicopters serial number 56001 
through 56046 and 58001 and 58002. 
 
[Model 427 helicopters serial numbers 56047 and 
58003 and subsequent will have the intent of this 
bulletin accomplished prior to delivery.] 
 
COMPLIANCE: See vendor bulletin. 
 
 
 
DESCRIPTION: 
 
 
The purpose of this bulletin is to achieve complete distribution of the attached vendor  
bulletin to the current affected model distribution list on record by Bell Helicopter. 
 
 
 
APPROVAL: 
 
See vendor bulletin approval.

### Page 3

SERVICE BULLETIN 
CLEVIS ASSEMBLY – HYDRAULIC SERVOACTUATOR, PART NUMBER 41011300 
 
1. Planning Information
A. Effectivity 
This service bulletin applies to the clevis assembly, P/N 41009477-101, used on the 
hydraulic servo assembly, HR part number 41011300-101 (BHT 206-076-062-105 
and -111).  The intent of this service bulletin has been incorporated into these servo 
actuators with serial numbers 807 and subsequent. 
B. Reason 
HR has discovered the possibility that the shaft (215) (refer to Figure 1) could be 
loose.  The looseness is as a result of lock washer tabs (220), improperly bent over 
the flat surface of the nut (225) or the flat surface of the clevis assembly (205). 
C. Description 
This service bulletin defines mandatory inspection of nut, shaft and, clevis assembly 
for possible looseness as result of improper lock washer installation.  This 
discrepancy is not traceable or identifiable except by inspection.  This inspection is 
applicable to servos identified in paragraph 1.A.of this bulletin. 
D. Approval 
HR Textron Engineering. 
E. Manpower 
Approximately 2.0 man-hour, are required to remove and reinstall each hydraulic 
servo actuator and approximately 0.5 man-hour is sufficient to conduct visual 
inspection. 
F. Material Price and Availability 
Prior to returning any servo to service center, contact HR Textron Customer Service 
and Field Service Manager at: 25200 West Rye Canyon Road, Santa Clarita, CA 
91355-1265; 661-702-5509, or 661-702-5358 (tel. numbers) 
mhowell@hrtextron.Textron.com (email); or 661-702-5970 (fax).  Provide HR 
Textron with the part number, serial number, time since new for new servo and in 
addition time since overhauled or repaired and the facility if the servo was recently 
overhauled or repaired.  This applies to servos that are found with loose nut, shaft 
or clevis assembly or improperly installed lock washer only.  Warranty claims will be 
handled on a case-by-case basis. 
G. Tooling Price and Availability 
New tools are not required. 
November 9, 2005  41011300-67-01 
EXPORT CONTROL WARNING 
This document contains technical data whose export, transfer, disclosure, and further  publication are restricted by  the applica ble 
export laws and regulations of the United States of America,  including the Export Administration Act of 1979, as amended, and the
Export Administration Regulations. Violations of these laws and regulations are subject to severe civil, criminal, and administ rative 
penalties. 
Revision 2 Page 1 of 4 
 
25200 W. Rye Canyon Road • Santa Clarita, California  91355-1265 • 661/294-6000 • FAX 661/259-9622

### Page 4

SERVICE BULLETIN 
 
 
H. Weight and Balance 
Not affected. 
I. Electrical Load Data 
Not affected. 
J. References 
67-32-09 Component Maintenance Manual with Illustrated Parts List (for) Hydraulic 
Servo Actuator Assembly part number 41011300-101 (BHT 206-076-062-105 and 
-111). 
K. Other Publications Affected 
The intent of this service bulletin will be incorporated into the next revision of 
67-32-09. 
2. Accomplishment Instructions 
A. Within the next 10 flight hours or before December 15, 2005, whichever comes first, 
accomplish this one-time mandatory inspection. 
B. Retract the boot (230) and perform the following inspections: 
1. Applying hand pressure only, and check if the nut, the shaft or the clevis 
assembly is turning independently from one another. 
2. If the shaft will turn independently to the nut or the clevis assembly, prior to 
the next flight, the actuator shall be removed from service and forwarded to 
HR Textron or one of the HR Textron Service Centers listed in Table 1.  
Check step 1.F. for condition. 
3. If the shaft is not turning independently from the nut or the clevis assembly 
proceed with step 2.B.4. 
4. Check if at least one tab of the lock washer is bent flush against one of the 
nut flat surface and if at least one tab of the lock washer is bent flush against 
one of the two flat surfaces of the clevis assembly.  Lock washer tab must 
also be in line with the flat surface of the nut and clevis assembly.  If the lock 
washer tabs are not bent flush against the nut and clevis assembly or are not 
in line with the flats, proceed with the following steps. 
5. If the lock washer tabs are not bent flush against the nut or clevis assembly 
flat surface, use needle-nosed pliers and make sure the lock washer tab is 
flush against nut or the flat surface of the clevis assembly. 
November 9, 2005  41011300-67-01 
Use or disclosure of data on this page are subject to the restriction on Page 1. 
Revision 2 Page 2 of 4 
 
25200 W. Rye Canyon Road • Santa Clarita, California  91355-1265 • 661/294-6000 • FAX 661/259-9622

### Page 5

SERVICE BULLETIN 
6. If the lock washer tab is on the edge or not aligned with a flat surface (nut or 
clevis assembly).  Within the next 300 hours, but not later than April 30, 2006, 
the actuator shall be removed from service and forwarded to HR Textron or 
one of the HR Textron Service Centers listed in Table 1.  Check step 1.F. for 
condition. 
C. If the servo meets all the requirements of the inspection or if the operator can 
accomplish the corrective action, the operator may perform the necessary corrective 
repairs.  Remove modification plate from servo and metal-impression stamp or 
vibro-etch an abbreviated service bulletin number (67-01) on modification plate to 
identify compliance with this service bulletin.  Modification plates are available; HR 
Textron will provide replacement modification plates if necessary.  Corrective action 
accomplished by HR Textron or approved repair station will have the same 
identification added to modification plate. 
Table 1.  HR Textron-Authorized Service Centers 
AEM Ltd Helicopter Support Inc. 
8 Wilton Road 116 Quarry Road 
Haine Industrial Estate Trumbull, CT  06611 (USA) 
Ramsgate, Kent CT12 5HE (England) 
Tel; 001-(44)-1-843-591-381 
Fax; 011-(44)-1-843-592-641 
Tel; (203) 416-4300 
Fax; (203) 416-4282 
 JAMCO Corp 
Stansted Airport 6-11-25 Osawa Mitaka 
Stansted, Essex CM24 1RB (England) 
Tel; 011-(44)-1-279-680-030 
Fax; 011-(44)-1-279-680-040 
Tokyo 181 (Japan) 
Tel; 011-(81) 422-31-6111 
Fax; 011 (81) 422-32-6998 
  
HASE Motorflug GmbH 
Helicopter Accessory Service Inc. East Baden-Airpark 
10102 Aileron Avenue Gebaude C-312 
Pensacola, FL  32506 (USA) D-77836 Rheinmunster, Germany 
Tel; (850) 456-8339 
Fax; (850) 456-5117 
Tel; 011 (49) 7229-301-430 
Fax; 011 (49) 7229-301-433 
  
HAS West Ostermans Aero AB 
Helicopter Accessory Service Inc. West Box 116 
10985 Penrose Street SE-190 46 Stockholm-Arlanda 
Sun Valley, CA  91352 (USA) 
Tel; (818) 767-2214 
Fax; (818) 767-2699 
Sweden 
Tel; 011-(46)-8-593-787-00 
Fax; 011-(46)-8-593-787-90 
  
HELITRADES HELITRADES 
18 Terry Fox Drive Site 5, Box 7, RR 2 Airdrie Airport 
Vanleek Hill, Ontario, Canada K0B 1R0 
Tel; (613) 678-3027 
Fax; (613) 678-2776  
Airdrie, Canada  K0B 1R0 
Tel; (403) 912-4658 
Fax; (403) 948-6475 
 
November 9, 2005  41011300-67-01 
Use or disclosure of data on this page are subject to the restriction on Page 1. 
Revision 2 Page 3 of 4 
 
25200 W. Rye Canyon Road • Santa Clarita, California  91355-1265 • 661/294-6000 • FAX 661/259-9622

### Page 6 (OCR)

HR TEXTRON
230
225
205
220
RETURN PORT
TEST PORT
PRESSURE PORT  MAIN INPUT
LINK ASSEMBLY
COVER, SPOOL AND
SLEEVE ASSEMBLY
OUTPUT END
ASSEMBLY
INPUT PIN
ACTUATOR HOUSING
ASSEMBLY
MODIFICATION
| CMM NO |
SER NO
PISTON ROD
NOTE:
ACCEPTABLE CONDITION
A MINIMUM OF ONE TAB SHALL BE IN LINE AND BENT FLUSH WITH
THE NUT FLAT SURFACE AND A MINIMUM OF ONE TAB SHALL BE IN LINE
AND BENT FLUSH WITH THE CLEVIS ASSEMBLY FLAT SURFACE
Clevis Assembly
Figure 1
Use or disclosure of data on this page are subject to the restriction on Page 1.
November 9, 2005  41011300-67-01
Revision 2  Page 4 of 4
25200 W. Rye Canyon Road • Santa Clarita, California 91355-1265 • 661/294-6000 • FAX 661/259-9622

### Page 7

SERVICE BULLETIN 
CLEVIS ASSEMBLY – HYDRAULIC SERVOACTUATOR, PART NUMBER 41011700 
 
 
1. Planning Information
A. Effectivity 
This service bulletin applies to the clevis assembly, P/N 41009477-101, used on the 
hydraulic servo assembly, HR part number 41011700-101 (BHT 206-076-062-109).  
The intent of this service bulletin has been incorporated into these servo actuators 
with serial numbers 230 and subsequent. 
B. Reason 
HR has discovered the possibility that the shaft (215) (refer to Figure 1) could be 
loose.  The looseness is as a result of lock washer tabs (220), improperly bent over 
the flat surface of the nut (225) or the flat surface of the clevis assembly (205). 
C. Description 
This service bulletin defines mandatory inspection of nut, shaft and, clevis assembly 
for possible looseness as result of improper lock washer installation.  This 
discrepancy is not traceable or identifiable except by inspection.  This inspection is 
applicable to servos identified in paragraph 1.A.of this bulletin. 
D. Approval 
HR Textron Engineering. 
E. Manpower 
Approximately 2.0 man-hour, are required to remove and reinstall each hydraulic 
servo actuator and approximately 0.5 man-hour is sufficient to conduct visual 
inspection. 
F. Material Price and Availability 
Prior to returning any servo to service center, contact HR Textron Customer Service 
and Field Service Manager at: 25200 West Rye Canyon Road, Santa Clarita, CA 
91355-1265; 661-702-5509, or 661-702-5358 (tel. numbers) 
mhowell@hrtextron.Textron.com (email); or 661-702-5970 (fax).  Provide HR 
Textron with the part number, serial number, time since new for new servo and in 
addition time since overhauled or repaired and the facility if the servo was recently 
overhauled or repaired.  This applies to servos that are found with loose nut, shaft 
or clevis assembly or improperly installed lock washer only.  Warranty claims will be 
handled on a case-by-case basis. 
November 9, 2005  41011700-67-01 
EXPORT CONTROL WARNING 
This document contains technical data whose export, transfer, disclosure, and further publication are restricted by  the applica ble
export laws and regulations of the United States of America,  including the Export Administration Act of 1979, as amended, and the
Export Administration Regulations. Violations of these laws and regulations are subject to severe civil, criminal, and administ rative
penalties. 
Revision 2 Page 1 of 4 
 
25200 W. Rye Canyon Road • Santa Clarita, California  91355-1265 • 661/294-6000 • FAX 661/259-9622

### Page 8

SERVICE BULLETIN 
 
G. Tooling Price and Availability 
New tools are not required. 
H. Weight and Balance 
Not affected. 
I. Electrical Load Data 
Not affected. 
J. References 
67-31-10 Component Maintenance Manual with Illustrated Parts List (for) Hydraulic 
Servo Actuator Assembly part number 41011700-101 (BHT 206-076-062-109). 
K. Other Publications Affected 
The intent of this service bulletin will be incorporated into the next revision of 
67-31-10. 
2. Accomplishment Instructions 
A. Within the next 10 flight hours or before December 15, 2005, whichever comes first, 
accomplish this one-time mandatory inspection. 
B. Retract the boot (230) and perform the following inspections: 
1. Applying hand pressure only, and check if the nut, the shaft or the clevis 
assembly is turning independently from one another. 
2. If the shaft will turn independently to the nut or the clevis assembly, prior to 
the next flight, the actuator shall be removed from service and forwarded to 
HR Textron or one of the HR Textron Service Centers listed in Table 1.  
Check step 1.F. for condition. 
3. If the shaft is not turning independently from the nut or the clevis assembly 
proceed with step 2.B.4. 
4. Check if at least one tab of the lock washer is bent flush against one of the 
nut flat surface and if at least one tab of the lock washer is bent flush against 
one of the two flat surfaces of the clevis assembly.  Lock washer tab must 
also be in line with the flat surface of the nut and clevis assembly.  If the lock 
washer tabs are not bent flush against the nut and clevis assembly or are not 
in line with the flats, proceed with the following steps. 
5. If the lock washer tabs are not bent flush against the nut or clevis assembly 
flat surface, use needle-nosed pliers and make sure the lock washer tab is 
flush against nut or the flat surface of the clevis assembly. 
Use or disclosure of data on this page are subject to the restriction on Page 1. 
November 9, 2005  41011700-67-01 
Revision 2 Page 2 of 4 
 
25200 W. Rye Canyon Road • Santa Clarita, California  91355-1265 • 661/294-6000 • FAX 661/259-9622

### Page 9

SERVICE BULLETIN 
6. If the lock washer tab is on the edge or not aligned with a flat surface (nut or 
clevis assembly).  Within the next 300 hours, but not later than April 30, 2006, 
the actuator shall be removed from service and forwarded to HR Textron or 
one of the HR Textron Service Centers listed in Table 1.  Check step 1.F. for 
condition. 
C. If the servo meets all the requirements of the inspection or if the operator can 
accomplish the corrective action, the operator may perform the necessary corrective 
repairs.  Remove modification plate from servo and metal-impression stamp or 
vibro-etch an abbreviated service bulletin number (67-01) on modification plate to 
identify compliance with this service bulletin.  Modification plates are available; HR 
Textron will provide replacement modification plates if necessary.  Corrective action 
accomplished by HR Textron or approved repair station will have the same 
identification added to modification plate. 
Table 1.  HR Textron-Authorized Service Centers 
AEM Ltd Helicopter Support Inc. 
8 Wilton Road 116 Quarry Road 
Haine Industrial Estate Trumbull, CT  06611 (USA) 
Ramsgate, Kent CT12 5HE (England) 
Tel; 001-(44)-1-843-591-381 
Fax; 011-(44)-1-843-592-641 
Tel; (203) 416-4300 
Fax; (203) 416-4282 
 JAMCO Corp 
Stansted Airport 6-11-25 Osawa Mitaka 
Stansted, Essex CM24 1RB (England) 
Tel; 011-(44)-1-279-680-030 
Fax; 011-(44)-1-279-680-040 
Tokyo 181 (Japan) 
Tel; 011-(81) 422-31-6111 
Fax; 011 (81) 422-32-6998 
  
HASE Motorflug GmbH 
Helicopter Accessory Service Inc. East Baden-Airpark 
10102 Aileron Avenue Gebaude C-312 
Pensacola, FL  32506 (USA) D-77836 Rheinmunster, Germany 
Tel; (850) 456-8339 
Fax; (850) 456-5117 
Tel; 011 (49) 7229-301-430 
Fax; 011 (49) 7229-301-433 
  
HAS West Ostermans Aero AB 
Helicopter Accessory Service Inc. West Box 116 
10985 Penrose Street SE-190 46 Stockholm-Arlanda 
Sun Valley, CA  91352 (USA) 
Tel; (818) 767-2214 
Fax; (818) 767-2699 
Sweden 
Tel; 011-(46)-8-593-787-00 
Fax; 011-(46)-8-593-787-90 
  
HELITRADES HELITRADES 
18 Terry Fox Drive Site 5, Box 7, RR 2 Airdrie Airport 
Vanleek Hill, Ontario, Canada K0B 1R0 
Tel; (613) 678-3027 
Fax; (613) 678-2776  
Airdrie, Canada  K0B 1R0 
Tel; (403) 912-4658 
Fax; (403) 948-6475 
 
November 9, 2005  41011700-67-01 
Use or disclosure of data on this page are subject to the restriction on Page 1. 
Revision 2 Page 3 of 4 
 
25200 W. Rye Canyon Road • Santa Clarita, California  91355-1265 • 661/294-6000 • FAX 661/259-9622

### Page 10 (OCR)

HR TEXTRON
230
225
215
RETURN PORT
TEST PORT
PRESSURE PORT  MAIN INPUT
LINK ASSEMBLY
COVER, SPOOL AND
SLEEVE ASSEMBLY
OUTPUT END
ASSEMBLY
INPUT PIN
ACTUATOR HOUSING
ASSEMBLY
(MODIFICATION  PLAT
I CM NO  PREV
SER NO  SB
PISTON ROD
NOTE:
A MINIMUM OF ONE TAB SHALL BE IN LINE AND BENT FLUSH WITH
THE NUT FLAT SURFACE AND A MINIMUM OF ONE TAB SHALL BE IN LINE
AND BENT FLUSH WITH THE CLEVIS ASSEMBLY FLAT SURFACE
Clevis Assembly
Figure 1
Use or disclosure of data on this page are subject to the restriction on Page 1.
November 9, 2005  41011700-67-01
Revision 2  Page 4 of 4
25200 W. Rye Canyon Road • Santa Clarita, California 91355-1265 • 661/294-6000 • FAX 661/259-9622

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.