# Boeing Special Attention Requirements Bulletin 737-35-1210 RB: No revision named

- Rights: © The Boeing Company. Filed by the FAA in regulations.gov docket FAA-2024-1697; AD 2024-13-02 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [Boeing Special Attention Requirements Bulletin 737-35-1210 RB](https://openairdocs.org/service-documents/boeing/737-35-1210-rb.md)
- Title as filed: RB_737-35-1210 RB
- Pages: 68
- PDF: https://openairdocs.org/files/sha256/40/8d/408dcad25583096da88e3badf9a7552d8946d44390169d9ab4be5b630bbbb8bd
- Page: https://openairdocs.org/service-documents/boeing/737-35-1210-rb/file/408dcad25583

## Text

Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

Commercial 
Airplanes
737
Requirements Bulletin
SPECIAL ATTENTION
Number: 737-35-1210 RB
Original Issue:
June 17, 2024
ATA System: 3522 2523
SUBJECT: OXYGEN - Passenger Oxygen System - Oxygen Generator and Thermal Pad Inspection
and Replacement
EXPORT CONTROLLED - This technology or software is subject to the U.S. Export Administration Regulations
(EAR), (15 C.F.R. Parts 730-774). No authorization from the U.S. Department of Commerce is required for
export, re-export, in-country transfer, or access EXCEPT to country group E:1 or E:2 countries/persons per
Supp.1 to Part 740 of the EAR.
9E991ECCN:
Copyright © 2024 The Boeing Company
Treatment of this document and its content is governed by contract with Boeing. Rights to use this document
are licensed on a per aircraft basis and such rights may not be transferable. For more information, contact The
Boeing Company.
Boeing, the Boeing signature, the Boeing symbol, 707, 717, 727, 737, 747, 757, 767, 777, 787, Dreamliner,
BBJ, DC-8, DC-9, DC-10, KC-10, KC-46, KDC-10, MD-10, MD-11, MD-80, MD-88, MD-90, P-8, Poseidon and
Boeing liveries are all trademarks owned by The Boeing Company; and no trademark license is granted in
connection with this document unless provided in writing by Boeing.
Original Issue: June 17, 2024
737-35-1210 RB
1 of 68
5.0

### Page 2

Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
2 of 68
REQUIREMENTS BULLETIN 737-35-1210
BLANK PAGE

### Page 3

Table of Contents
1. EFFECTIVITY .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
A. Airplanes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
B. Spares Affected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2. CONCURRENT REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3. COMPLIANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4. APPROVAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5. ACCOMPLISHMENT INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
A. General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
B. Work Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
FIGURE 1: PASSENGER COMPARTMENT - THERMAL PAD INSPECTION [Group 1-2, Configuration 1]
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
FIGURE 2: PASSENGER COMPARTMENT - THERMAL PAD INSPECTION [Group 1-2, Configuration 2]
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
FIGURE 3: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
EXPENDED INSPECTION [Group 1-2, Configuration 1] . . . . . . . . . . . . . . . . . . . 30
FIGURE 4: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
EXPENDED INSPECTION [Group 1-2, Configuration 2] . . . . . . . . . . . . . . . . . . . 33
FIGURE 5: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR AND
THERMAL PAD REPLACEMENT [Group 1-2, Configuration 1] . . . . . . . . . . . . . . . 36
FIGURE 6: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR AND
THERMAL PAD REPLACEMENT [Group 1-2, Configuration 2] . . . . . . . . . . . . . . . 39
FIGURE 7: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
THERMAL PAD REPLACEMENT [Group 1-2, Configuration 1] . . . . . . . . . . . . . . . 42
FIGURE 8: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
THERMAL PAD REPLACEMENT [Group 1-2, Configuration 2] . . . . . . . . . . . . . . . 45
FIGURE 9: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
REPOSITION [Group 2, Configuration 1] . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
FIGURE 10: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
REPOSITION [Group 2, Configuration 2] . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
FIGURE 11: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
REPOSITION AND THERMAL PAD REPLACEMENT [Group 2, Configuration 1] . . . . . 54
FIGURE 12: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
REPOSITION AND THERMAL PAD REPLACEMENT [Group 2, Configuration 2] . . . . . 57
FIGURE 13: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
POSITION INSPECTION [Group 2, Configuration 1] . . . . . . . . . . . . . . . . . . . . . 60
FIGURE 14: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
POSITION INSPECTION [Group 2, Configuration 2] . . . . . . . . . . . . . . . . . . . . . 63
APPENDIX D: EXPENDED PSU OXYGEN GENERATOR . . . . . . . . . . . . . . . . . . . . . . . . . . 66
APPENDIX E: NOT EXPENDED PSU OXYGEN GENERATOR . . . . . . . . . . . . . . . . . . . . . . . 67
APPENDIX H: SPACING REQUIREMENT OF LESS THAN 0.1-INCH BETWEEN THE PSU OXYGEN
GENERATOR AND THE OXYGEN MASK BOX [Group 2] . . . . . . . . . . . . . . . . . . 68
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
3 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 4

Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
4 of 68
REQUIREMENTS BULLETIN 737-35-1210
BLANK PAGE

### Page 5

Commercial 
Airplanes
737
Requirements Bulletin
SPECIAL ATTENTION
Number: 737-35-1210 RB
Original Issue:
June 17, 2024
ATA System: 3522 2523
SUBJECT: OXYGEN - Passenger Oxygen System - Oxygen Generator and Thermal Pad Inspection
and Replacement
BOEING RECOMMENDS THAT EACH OPERATOR EXAMINE THIS DOCUMENT IMMEDIATELY. THIS IS
AN ENHANCED REQUIRED FOR COMPLIANCE DOCUMENT. THE BOEING PROCESSES USED TO CREATE
THE SERVICE BULLETIN (SB) AND THE REQUIREMENTS BULLETIN (RB) ENSURE THAT THE
INFORMATION BETWEEN "RC START" AND "RC END" IN THE SB ARE IDENTICAL TO THE INFORMATION
IN THE SAME SECTIONS (COMPLIANCE, WORK INSTRUCTIONS…) OF THE RB WHICH THE SB REFERS
TO AS THE RELATED DOCUMENT.
1.
Effectivity
A. Airplanes
This bulletin is applicable to 737-8, 737-9, 737-8200 Airplane(s), line number(s) 5602, 5668, 5788,
5852, 5902, 5948, 5992, 6034, 6074, 6114, 6154, 6188, 6222, 6250, 6272, 6290, 6308, 6326,
6344, 6360, 6372, 6384, 6396, 6408, 6420, 6430, 6441, 6448, 6456, 6464, 6472, 6481, 6490,
6499, 6508, 6515, 6521, 6528, 6535, 6542, 6548, 6555, 6562, 6569, 6575, 6582, 6589, 6594,
6598, 6603, 6607, 6612, 6616, 6621, 6625, 6630, 6634, 6639, 6643, 6648, 6652, 6657, 6661,
6666, 6672, 6677, 6681, 6686, 6690, 6695, 6699, 6704, 6708, 6713, 6717, 6722, 6726, 6731,
6735, 6740, 6749, 6753, 6758, 6762, 6767, 6771, 6776, 6780, 6783, 6785, 6789, 6792, 6794,
6796, 6803, 6805, 6807, 6810, 6814, 6816, 6819, 6821, 6825, 6828, 6830, 6834, 6837, 6839,
6841, 6843, 6848, 6850, 6852, 6855, 6859, 6861, 6864, 6866, 6868, 6872, 6875, 6877, 6881,
6884, 6886, 6890, 6893, 6895, 6897, 6899, 6904, 6906, 6908, 6911, 6915, 6917, 6920, 6922,
6926, 6929, 6931, 6935, 6938, 6940, 6942, 6944, 6949, 6951, 6953, 6956, 6960, 6963, 6965,
6968, 6970, 6973, 6975-6976, 6978, 6980, 6983, 6985, 6988, 6990-6991, 6993, 6995, 6998, 7000,
7003, 7005-7006, 7008, 7010, 7013, 7015, 7018, 7020, 7023, 7025, 7027-7028, 7030, 7033, 7035,
7038, 7040, 7042-7043, 7045, 7048, 7050, 7053, 7055, 7060, 7062, 7064-7065, 7068, 7070, 7073,
7075, 7077, 7079-7080, 7083, 7085, 7088, 7090, 7093, 7095-7096, 7098, 7100, 7103, 7105, 7108,
7110-7111, 7113, 7115, 7118, 7120, 7123, 7125, 7128, 7130, 7132-7133, 7135, 7138, 7140, 7143,
7145, 7147-7148, 7150, 7153, 7155, 7158, 7160, 7163, 7165-7166, 7168, 7170, 7173, 7175, 7178,
7180-7181, 7183, 7185-7186, 7188, 7190, 7192-7193, 7195-7196, 7198, 7200-7201, 7203, 7205,
7207-7208, 7210-7211, 7213, 7215-7216, 7218, 7220, 7222-7223, 7225-7226, 7228, 7230-7231,
7233, 7236-7238, 7240-7241, 7245-7246, 7248, 7250, 7252-7253, 7255-7256, 7258, 7260-7261,
7265, 7267-7268, 7270-7271, 7273, 7275-7276, 7278, 7281-7283, 7285-7286, 7288, 7290-7291,
7293, 7295-7296, 7298, 7300-7301, 7303, 7305-7306, 7308, 7310-7311, 7313, 7315-7316, 7318,
7320-7321, 7323, 7325-7326, 7328, 7330-7331, 7333, 7335-7336, 7338, 7340-7341, 7343, 7345,
7348, 7350, 7353, 7355-7356, 7358, 7360-7361, 7363, 7365-7366, 7368, 7370, 7373, 7375-7376,
7378, 7380-7381, 7383-7386, 7388-7391, 7393-7396, 7398-7401, 7403-7406, 7409-7411,
7413-7414, 7416, 7418-7421, 7423-7426, 7428-7431, 7433-7436, 7438-7439, 7441, 7443-7446,
7448-7451, 7453-7454, 7456, 7458-7461, 7463-7466, 7468-7471, 7473-7476, 7478-7481,
7483-7484, 7486, 7488-7491, 7494-7495, 7498-7501, 7503-7505, 7509, 7513-7516, 7518,
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
5 of 68

### Page 6

7520-7521, 7523-7526, 7528-7529, 7531, 7533-7536, 7538-7541, 7543-7544, 7548-7551,
7553-7556, 7558-7561, 7563-7566, 7568-7569, 7571, 7573-7574, 7576, 7578-7580, 7583-7586,
7588-7591, 7593-7594, 7596, 7598-7602, 7604-7612, 7614-7618, 7620-7623, 7625-7641, 7643,
7647-7650, 7652-7661, 7663-7675, 7678-7679, 7681-7686, 7688-7689, 7692-7696, 7698-7704,
7707-7714, 7717-7719, 7721-7727, 7729-7737, 7739-7749, 7752-7756, 7758-7759, 7762-7763,
7765-7774, 7776-7781, 7783, 7785-7791, 7793-7794, 7797, 7799-7808, 7810-7812, 7814-7816,
7818-7825, 7827-7830, 7832, 7835-7847, 7849-7855, 7857-7859, 7861-7864, 7866, 7868-7871,
7873-7874, 7876-7877, 7879-7886, 7888-7904, 7909, 7913, 7915-7918, 7922-7923, 7926-7928,
7937-7938, 7942-7943, 7945-7947, 7951, 7953, 7957, 7959-7961, 7965, 7967, 7972, 7975-7976,
7982, 7984, 7990-7992, 7994, 7996, 7998-8000, 8002-8003, 8006, 8009, 8013-8014, 8016,
8019-8021, 8023-8024, 8033-8036, 8040, 8042-8044, 8047, 8051-8052, 8054, 8063, 8066, 8069,
8071-8073, 8075-8077, 8087, 8090-8092, 8094, 8099, 8101-8102, 8104-8124, 8126-8138,
8140-8141, 8143-8177, 8179, 8182-8185, 8187-8188, 8190-8193, 8195-8197, 8199-8205,
8207-8210, 8214-8218, 8222-8228, 8230-8233, 8236-8241, 8243, 8245-8247, 8249-8252,
8255-8256, 8258-8262, 8264-8265, 8267, 8269, 8271-8279, 8281-8283, 8286-8287, 8289-8290,
8292, 8298-8299, 8301, 8304, 8309-8311, 8313-8314, 8316, 8319, 8322-8326, 8329-8331,
8335-8336, 8340-8341, 8343-8346, 8348-8353, 8355-8363, 8365-8371, 8374-8381, 8383-8386,
8388-8389, 8391-8392, 8394-8396, 8398-8399, 8401-8402, 8404-8410, 8412-8417, 8419,
8421-8422, 8424-8427, 8429-8448, 8450-8487, 8489-8494, 8496-8525, 8527-8540, 8543-8564,
8566-8591, 8593-8602, 8604-8633, 8635-8641, 8643-8665, 8667, 8669-8679, 8681-8696,
8699-8718, 8720-8724, 8726-8745, 8747-8748, 8750, 8752-8756, 8758-8770, 8772-8794,
8797-8806, 8808-8818, 8820-8833, 8835-8837, 8839-8845, 8847, 8849-8850, 8852, 8854,
8856-8863, 8865-8868, 8870-8871, 8873, 8875-8878, 8880-8881, 8884-8887, 8889-8890, 8893,
8898, 8900, 8902, 8904, 8906-8907, 8909, 8912, 8919, 8922, 8924, 8926, 8937, 8945, 8951, 8956
in 2 Group(s). Where the effectivity is presented with hyphens between line numbers, the airplane
applicability means "through" and "inclusive", e.g. line numbers 1-9 means line numbers 1 through
9 inclusive.
The Variable Numbers and Group Information for the applicable airplanes is given below.
DESCRIPTIONCONFIGURATIONGROUP
737-8/-8200/-9 airplanes with Boeing Sky Interior (BSI) that could
have Passenger Service Unit (PSU) Oxygen Generators with Pressure
Sensitive Adhesive (PSA) thermal pads installed and require a
different compliance time. These airplanes were manufactured during
a period when PSA thermal pads were used as an alternate
configuration.
- 1
Airplanes that have 12-minute PSU Oxygen Generators installed.1
Airplanes that have 22-minute PSU Oxygen Generators installed.2
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
6 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 7

DESCRIPTIONCONFIGURATIONGROUP
737-8/-8200/-9 airplanes with BSI that could have PSU Oxygen
Generators with PSA thermal pads installed and require a different
compliance time. These airplanes were not manufactured during a
period when PSA thermal pads were used as an alternate
configuration. The PSUs that used PSA thermal pads may have
replaced the delivered PSUs during spares or post-delivery
modification.
- 2
Airplanes that have 12-minute PSU Oxygen Generators installed.1
Airplanes that have 22-minute PSU Oxygen Generators installed.2
Airplane Models:
737-8, 737-8200, 737-9
GroupVariable Number
21A001 - 1A002
21A004 - 1A044
11A045 - 1A062
11A070 - 1A093
11A098 - 1A099
11A101 - 1A163
11A184 - 1A197
21A201 - 1A209
21A211 - 1A215
11A251 - 1A253
21A301 - 1A324
11A325 - 1A332
11A366
11A385 - 1A391
21A392 - 1A393
21A401 - 1A413
11A414
11A416
11A418 - 1A428
21A451 - 1A467
GroupVariable Number
21A476 - 1A494
11A495 - 1A498
21A501 - 1A502
21A521 - 1A523
21A531
21A541 - 1A546
11A547
11A549
21A551 - 1A552
21A601 - 1A615
21A617
21A620
11A621
11A624
11A626
11A628
21A630
11A631
21A676 - 1A691
21A705
GroupVariable Number
21A707
21A711
21A718
21A726 - 1A730
21A741 - 1A743
21A751 - 1A759
11A760 - 1A761
21A801
21A851 - 1A873
11A874 - 1A880
11A884
11A887 - 1A897
21A899
21A901
21A916 - 1A921
21A926 - 1A934
21A943 - 1A944
11A945
21A951 - 1A959
11A960 - 1A964
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
7 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 8

GroupVariable Number
11A967 - 1A968
21A969
21B001 - 1B014
11B015 - 1B032
11B035 - 1B047
21B071
11B072
21B073
21B101 - 1B133
11B134 - 1B142
11B151 - 1B167
21B169
21B201 - 1B211
11B212 - 1B214
11B216 - 1B217
21B251 - 1B266
21B268 - 1B274
11B277
21B282
21B285 - 1B286
21B288
11B326 - 1B329
11B366 - 1B370
21B376 - 1B381
21B384 - 1B393
21B396 - 1B397
11B398
21B401 - 1B402
11B405
21B411 - 1B412
11B436 - 1B437
21B491 - 1B494
11B495 - 1B497
GroupVariable Number
21B511 - 1B512
21B514
21B516 - 1B517
21B521 - 1B522
21B527
21B531 - 1B534
21B540 - 1B541
21B566 - 1B569
11B570
21B576 - 1B578
21B601
21B635 - 1B636
21B651 - 1B657
21B660
21B664
21B678
21B681
21B701 - 1B702
11B703 - 1B704
21B785
11B786
21B795
11B796
21B801 - 1B810
11B811 - 1B815
11B820 - 1B825
11B831 - 1B835
21B930 - 1B934
21B938 - 1B939
11B941
21B952
21C001 - 1C003
11C004 - 1C005
GroupVariable Number
11C007 - 1C009
11C011
21C201 - 1C204
11C205 - 1C211
21C221 - 1C222
11C223 - 1C224
21C237 - 1C238
11C239 - 1C240
11C246
21C256
11C257 - 1C268
21C301 - 1C308
11C309 - 1C310
21C326 - 1C335
21C337
21C379
21C389
21C401 - 1C404
21C406 - 1C407
11C408
11C410 - 1C411
11C414 - 1C418
21C419
11C420
21C451
21C453
21C455
21C501 - 1C515
11C516 - 1C517
21C690 - 1C694
21C701 - 1C719
11C720
21C826 - 1C827
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
8 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 9

GroupVariable Number
21C841 - 1C842
21C844 - 1C845
21C861 - 1C863
11C886
21C946 - 1C948
11C949 - 1C950
21D001 - 1D004
21D051 - 1D060
11D061 - 1D079
21D080 - 1D082
21D101 - 1D126
11D127 - 1D179
21D201 - 1D204
21D236 - 1D238
21D251 - 1D253
21D401 - 1D403
11D404
21D426 - 1D427
11D428 - 1D464
21D466 - 1D470
21D501
11D502 - 1D503
11D521 - 1D523
21D524
11D531 - 1D534
21D601
11D602 - 1D619
11D701
11D703
11D751 - 1D766
21D767 - 1D772
11D886
21D887
GroupVariable Number
21F001 - 1F005
11F006 - 1F099
11F101 - 1F135
21F136
11F137 - 1F138
21F139
11F140
21F141
11F142 - 1F143
21F144 - 1F145
11F146 - 1F147
21F148 - 1F156
11F201
11J001 - 1J002
21J021 - 1J023
21J041 - 1J044
21J066 - 1J067
21J101 - 1J104
11J105 - 1J114
11J122 - 1J126
11J132 - 1J133
21J134
21J301 - 1J302
21J401 - 1J404
11J585
21J590 - 1J594
21J601 - 1J602
11J606
21J611
11J926 - 1J932
21K001 - 1K002
11K003
21K016 - 1K018
GroupVariable Number
21K041 - 1K042
11K043
11K045
11K086
11K101 - 1K103
21K301 - 1K305
11K306 - 1K309
11K311 - 1K313
21K314
21K351 - 1K354
11K355
11K380
21K384
21K401 - 1K402
21K426
11K447 - 1K450
21K701 - 1K704
21K726 - 1K727
11K731 - 1K732
11K751
21K976
11K977 - 1K980
21L001
21L075 - 1L076
11L077 - 1L078
11L083 - 1L084
21L101 - 1L102
11L103
21L104
11L105
21L106 - 1L107
21L202
11L266 - 1L268
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
9 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 10

GroupVariable Number
21L301
11L302
11L402 - 1L404
11L406
11L451 - 1L466
11L468 - 1L480
11L483 - 1L496
11L498 - 1L499
11L501 - 1L513
21L514 - 1L515
11L516 - 1L517
11L519 - 1L521
21L522
11L523
21L525
GroupVariable Number
21L536
11L701
11M002 - 1M004
21M005
21M008
11M201 - 1M203
11M205 - 1M207
21M236
11M841 - 1M846
11M901
11M951 - 1M952
11N201 - 1N230
11N232 - 1N240
11N242
21N243
GroupVariable Number
11N244 - 1N245
21N246
11N247 - 1N251
21N252
11N253 - 1N254
21N255
11N256
21N257
11N501 - 1N502
11N701 - 1N702
21N703
11N851
21N852 - 1N853
21N855
--
B.
Spares Affected
Examine your spares supply for the parts or components identified below. If any parts or components
are found, refer to Paragraph 3.B., Work Instructions for the recommended action.
Group 1-2, Configuration 1:
Part Number
53010
E71740-00 OR S417T401-44
Group 1-2, Configuration 2:
Part Number
73667
E72280-00 OR S417T401-63
2.
CONCURRENT REQUIREMENTS
None.
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
10 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 11

3. COMPLIANCE
The Federal Aviation Administration (FAA) will possibly release an Airworthiness Directive related to
Requirements Bulletin 737-35-1210 RB. The Airworthiness Directive will make the compliance tasks and
times given in Requirements Bulletin 737-35-1210 RB mandatory.
Accomplish the required actions, based on the applicable conditions in Tables 1 and 2, in accordance with
Accomplishment Instructions.
When more than one OPTION is given for a CONDITION, do only one of the OPTION numbers. When
more than one ACTION is given for a CONDITION or an OPTION, do all of the ACTION numbers for that
CONDITION or OPTION.
Group 1:
Table 1: Passenger Service Unit (PSU) Oxygen Generator and Thermal Pad Inspection and Replacement
Repeat Interval (Not to
Exceed)
Boeing Recommended
Compliance Time
ActionCondition
-Within 120 days after the
Original Issue date of Re-
quirements Bulletin 737-
35-1210 RB.
Do a General Visual In-
spection (GVI) of the Pas-
senger Service Unit (PSU)
Oxygen Generator to de-
termine retention straps
thermal pads configura-
tion.
All Airplanes
--No further action is re-
quired.
CONDITION 1: ANY PSU
OXYGEN GENERATOR
WITHOUT PRESSURE
SENSITIVE ADHESIVE
(PSA) RETENTION
STRAPS THERMAL
PADS FOUND
-Before further flight.Do a GVI of the affected
PSU Oxygen Generator
to determine if expended.
CONDITION 2: ANY PSU
OXYGEN GENERATOR
WITH PSA RETENTION
STRAPS THERMAL
PADS FOUND
-Before further flight.Replace with new or ser-
viceable PSU Oxygen
Generator and replace
PSA retention strap ther-
mal pads with non-PSA
retention strap thermal
pads. (a)
CONDITION 2.1: AFFECT-
ED PSU OXYGEN GEN-
ERATOR EXPENDED
-Before further flight.Replace PSA retention
strap thermal pads with
non-PSA retention strap
thermal pads.
CONDITION 2.2: AFFECT-
ED PSU OXYGEN GEN-
ERATOR NOT EXPEND-
ED
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
11 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 12

Group 1:
Table 1: Passenger Service Unit (PSU) Oxygen Generator and Thermal Pad Inspection and Replacement
Repeat Interval (Not to
Exceed)
Boeing Recommended
Compliance Time
ActionCondition
(a) A serviceable PSU Oxygen Generator is defined as a PSU Oxygen Generator that has not been expended
and has not expired (i.e., the PSU Oxygen Generator does not exceed the life limit established for that
generator by the manufacturer).
Group 2:
Table 2: Passenger Service Unit (PSU) Oxygen Generator and Thermal Pad Inspection and Replacement
Repeat Interval (Not to
Exceed)
Boeing Recommended
Compliance Time
ActionCondition
-Within 120 days after the
Original Issue date of Re-
quirements Bulletin 737-
35-1210 RB.
Do a General Visual In-
spection (GVI) of the Pas-
senger Service Unit (PSU)
Oxygen Generator to de-
termine retention straps
thermal pads configura-
tion.
All Airplanes
--No further action is re-
quired.
CONDITION 1: ANY PSU
OXYGEN GENERATOR
WITHOUT PRESSURE
SENSITIVE ADHESIVE
(PSA) RETENTION
STRAPS THERMAL
PADS FOUND
-Within 150 days after the
Original Issue date of Re-
quirements Bulletin 737-
35-1210 RB.
Do a GVI of the affected
PSU Oxygen Generator
to determine if expended
and installation migration.
CONDITION 2: ANY PSU
OXYGEN GENERATOR
WITH PSA RETENTION
STRAPS THERMAL
PADS FOUND
-Before further flight.(OPTION 1): Replace
PSA retention strap ther-
mal pads with non-PSA
retention strap thermal
pads and reposition affect-
ed PSU Oxygen Genera-
tor.
CONDITION 2.1: AFFECT-
ED PSU OXYGEN GEN-
ERATOR MIGRATION
FOUND AND NOT EX-
PENDED
-Before further flight.(OPTION 2) (ACTION 1):
Reposition affected PSU
Oxygen Generator.
-Within 150 days after the
Original Issue date of Re-
quirements Bulletin 737-
35-1210 RB.
(OPTION 2) (ACTION 2):
Make sure affected PSU
Oxygen Generator migra-
tion is not found and has
not been expended.
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
12 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 13

Group 2:
Table 2: Passenger Service Unit (PSU) Oxygen Generator and Thermal Pad Inspection and Replacement
Repeat Interval (Not to
Exceed)
Boeing Recommended
Compliance Time
ActionCondition
-Before further flight after
making sure affected PSU
Oxygen Generator migra-
tion is not found and has
not been expended.
Replace PSA retention
strap thermal pads with
non-PSA retention strap
thermal pads.
CONDITION 2.1.1: AF-
FECTED PSU OXYGEN
GENERATOR MIGRA-
TION IS NOT FOUND
AND HAS NOT BEEN
FOUND EXPENDED
DURING (OPTION 2)
(ACTION 2)
-Before further flight after
determining affected PSU
Oxygen Generator migrat-
ed.
CONDITION 2.1.2 (AC-
TION 1): Reposition affect-
ed PSU Oxygen Genera-
tor.
CONDITION 2.1.2: AF-
FECTED PSU OXYGEN
GENERATOR MIGRA-
TION IS FOUND AND
HAS NOT BEEN FOUND
EXPENDED DURING
(OPTION 2) (ACTION 2)
CONDITION 2.1.2 (AC-
TION 2): Replace PSA re-
tention strap thermal pads
with non-PSA retention
strap thermal pads.
-Before further flight after
determining affected PSU
Oxygen Generator has
been expended.
CONDITION 2.1.3 (AC-
TION 1): Replace with
new or serviceable PSU
Oxygen Generator. (a)
CONDITION 2.1.3: AF-
FECTED PSU OXYGEN
GENERATOR HAS BEEN
FOUND EXPENDED
DURING (OPTION 2)
(ACTION 2) CONDITION 2.1.3 (AC-TION 2): Replace PSA re-
tention strap thermal pads
with non-PSA retention
strap thermal pads.
-Before further flight.CONDITION 2.2 (ACTION
1): Replace with new or
serviceable PSU Oxygen
Generator. (a)
CONDITION 2.2: AFFECT-
ED PSU OXYGEN GEN-
ERATOR HAS BEEN EX-
PENDED
CONDITION 2.2 (ACTION
2): Replace PSA retention
strap thermal pads with
non-PSA retention strap
thermal pads.
-Within 150 days after the
Original Issue date of Re-
quirements Bulletin 737-
35-1210 RB.
Replace PSA retention
strap thermal pads with
non-PSA retention strap
thermal pads.
CONDITION 2.3: AFFECT-
ED PSU OXYGEN GEN-
ERATOR NOT EXPEND-
ED AND NO MIGRATION
FOUND
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
13 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 14

Group 2:
Table 2: Passenger Service Unit (PSU) Oxygen Generator and Thermal Pad Inspection and Replacement
Repeat Interval (Not to
Exceed)
Boeing Recommended
Compliance Time
ActionCondition
(a) A serviceable PSU Oxygen Generator is defined as a PSU Oxygen Generator that has not been expended
and has not expired (i.e., the PSU Oxygen Generator does not exceed the life limit established for that
generator by the manufacturer).
4.
APPROVAL
This Requirements Bulletin was examined by the Federal Aviation Administration (FAA). The changes
specified in this document comply with the applicable regulations and are FAA approved, as well as European
Union Aviation Safety Agency (EASA)/Joint Aviation Authorities (JAA) approved for all EASA/JAA approved
airplanes listed in this Requirements Bulletin effectivity. This document and its approval were based on the
airplane in its original Boeing delivery configuration or as modified by other Boeing changes.
If an airplane has a non-Boeing modification or repair that affects a component or system also affected by
this Requirements Bulletin, the operator is responsible for obtaining appropriate regulatory agency approval
before incorporating this Requirements Bulletin.
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
14 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 15

5.    ACCOMPLISHMENT INSTRUCTIONS
A.
GENERAL INFORMATION
OBEY THE MANUFACTURER'S PROCEDURES WHEN YOU DO TASKS THAT
ARE RELATED TO AIRWORTHINESS LIMITATIONS (AWL). IF YOU DO NOT
OBEY THE PROCEDURES, IT CAN INCREASE THE RISK OF A SOURCE OF
IGNITION. INJURIES TO PERSONNEL, AND DAMAGE TO EQUIPMENT CAN
OCCUR IF THERE IS A FIRE OR EXPLOSION.
WARNING
NOTE: 1. This is an Enhanced Required for Compliance document. There will be a separate
Service Bulletin (SB) and a separate Requirements Bulletin (RB). If an RB is mandated
by an Airworthiness Directive (AD), then all applicable requirements specified in the
RB must be done. In the RB, the "Refer to the listed procedures..." column of the
table(s) in the Work Instructions is for reference only. The procedures in that column
are not required by the AD and are for guidance only. For the related SB, some
locations are marked RC Start and RC End to identify the requirements that are
restated from the RB. For the related SB, the areas between RC Start and RC End,
including sub-steps and any figures identified between RC Start and RC End, must
be done to comply with the AD. Therefore, an Alternative Method of Compliance
(AMOC) is required for any deviations to steps between RC Start and RC End,
including substeps and identified figures. For the related SB, the steps not between
RC Start and RC End may be deviated from using accepted methods in accordance
with the operator's maintenance or inspection program without obtaining approval
of an AMOC; this is provided that the steps between RC Start and RC End, including
sub-steps and identified figures, can still be done as specified, and the airplane can
be put back in an airworthy condition. Figures not required for compliance are omitted
from the RB.
2.
This is an Enhanced Required for Compliance document. The Boeing processes
used to create the Service Bulletin (SB) and the Requirements Bulletin (RB) ensure
that the information between "RC Start" and "RC End" in the SB are identical to the
information in the same sections (Compliance, Work Instructions...) of the RB which
the SB refers to as the related document.
3. The compliance times for the actions in WORK INSTRUCTIONS are in Compliance.
4. Unless shown differently, these dimensions and tolerances are used:
– Linear dimensions are in inches
– Tolerance on linear dimensions, other than rivet and bolt edge margins, is plus
or minus 0.03 inch
– Tolerance on rivet and bolt edge margin is plus or minus 0.05 inch
– Angular tolerance is plus or minus 2 degrees
– Hole dimensions for standard solid rivets and fasteners are in Structural Repair
Manual (SRM) Chapter 51
– Torque Values:
— Values for structural fasteners are given in 737 Structural Repair Manual,
Chapter 51.
— Values for airframe maintenance tasks are included in Chapter 20 of 737
Aircraft Maintenance Manual (AMM).
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
15 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 16

— Values for electrical maintenance tasks are included in Chapter 20 of
Standard Wiring Practices Manual (SWPM).
—
Values for engine maintenance tasks are included in Chapter 70 of 737
Aircraft Maintenance Manual (AMM).
— Non-standard torque values for maintenance tasks are included in the
applicable installation step.
5. These work instructions refer to procedures included in other Boeing documents.
When the words "refer to" are used and the operator has an accepted alternative
procedure, the accepted alternative procedure can be used. When the words "in
accordance with" are included in the instruction, the procedure in the Boeing document
must be used.
6. Where the work instructions include installation of a kept part, a new or serviceable
part with the same part number can be installed as an alternative to the kept part.
7. If it is necessary to remove more parts for access, you can remove those parts. If
you can get access without removing identified parts, it is not necessary to remove
all of the identified parts. Jacking and shoring limitations must be observed.
8. A General Visual Inspection (GVI) is defined as: A visual examination of an interior
or exterior area, installation or assembly to detect obvious damage, failure or
irregularity. This level of inspection is made from within touching distance, unless
otherwise specified. A mirror may be necessary to enhance visual access to all
exposed surfaces in the inspection area. This level of inspection is made under
normally available lighting conditions such as daylight, hangar lighting, flashlight or
drop-light and may require removal or opening of access panels or doors. Stands,
ladders or platforms may be required to gain proximity to the area being checked.
Basic cleaning may be required to ensure appropriate visibility.
9. An "Expended" Passenger Service Unit (PSU) Oxygen Generator is defined as an
oxygen generator which has been discharged and can no longer provide supplemental
oxygen. It is indicated as "Expended" when the temperature sensitive indicator has
changed color from white/yellow ("Not Expended") to black/brown ("Expended").
10. Refer to APPENDIX D for an example of an Expended PSU Oxygen Generator.
11. Refer to APPENDIX E as an example of a Not Expended PSU Oxygen Generator.
12. Refer to APPENDIX H for the spacing requirement of less than 0.1-inch between
the PSU Oxygen Generator and the Oxygen Mask Box.
13. When more than one OPTION is given for a CONDITION, do only one of the OPTION
numbers. When more than one ACTION is given for a CONDITION or an OPTION,
do all of the ACTION numbers for that CONDITION or OPTION.
B. WORK INSTRUCTIONS
Actions Required for Compliance
1. Requirements
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
16 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 17

Group 1, Configuration 1:
Table 1: Passenger Service Unit (PSU) Oxygen Generator and Thermal Pad Inspection and Replacement
Refer to the listed proce-
dures in SB 737-35-1210
Original Issue or later
approved revisions as
an accepted procedure.
Method of ComplianceActionCondition
PART 1: PASSENGER
COMPARTMENT AND
PSU ACCESS
-Do a General Visual In-
spection (GVI) of the Pas-
senger Service Unit (PSU)
Oxygen Generator to de-
termine retention straps
thermal pads configura-
tion.
All Airplanes
-FIGURE 1
PART 2: PASSENGER
COMPARTMENT AND
PSU CLOSE ACCESS
-No further action is re-
quired.
CONDITION 1: ANY PSU
OXYGEN GENERATOR
WITHOUT PRESSURE
SENSITIVE ADHESIVE
(PSA) RETENTION
STRAPS THERMAL
PADS FOUND
PART 3: RESTORATION-
-FIGURE 3Do a GVI of the affected
PSU Oxygen Generator
to determine if expended.
CONDITION 2: ANY PSU
OXYGEN GENERATOR
WITH PSA RETENTION
STRAPS THERMAL
PADS FOUND
-FIGURE 5Replace with new or ser-
viceable PSU Oxygen
Generator and replace
PSA retention strap ther-
mal pads with non-PSA
retention strap thermal
pads. (a)
CONDITION 2.1: AFFECT-
ED PSU OXYGEN GEN-
ERATOR EXPENDED PART 2: PASSENGERCOMPARTMENT AND
PSU CLOSE ACCESS
-
PART 3: RESTORATION-
-FIGURE 7Replace PSA retention
strap thermal pads with
non-PSA retention strap
thermal pads.
CONDITION 2.2: AFFECT-
ED PSU OXYGEN GEN-
ERATOR NOT EXPEND-
ED
PART 2: PASSENGER
COMPARTMENT AND
PSU CLOSE ACCESS
-
PART 3: RESTORATION-
(a) A serviceable PSU Oxygen Generator is defined as a PSU Oxygen Generator that has not been expended
and has not expired (i.e., the PSU Oxygen Generator does not exceed the life limit established for that
generator by the manufacturer).
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
17 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 18

Group 2, Configuration 1:
Table 2: Passenger Service Unit (PSU) Oxygen Generator and Thermal Pad Inspection and Replacement
Refer to the listed proce-
dures in SB 737-35-1210
Original Issue or later
approved revisions as
an accepted procedure.
Method of ComplianceActionCondition
PART 1: PASSENGER
COMPARTMENT AND
PSU ACCESS
-Do a General Visual In-
spection (GVI) of the Pas-
senger Service Unit (PSU)
Oxygen Generator to de-
termine retention straps
thermal pads configura-
tion.
All Airplanes
-FIGURE 1
PART 2: PASSENGER
COMPARTMENT AND
PSU CLOSE ACCESS
-No further action is re-
quired.
CONDITION 1: ANY PSU
OXYGEN GENERATOR
WITHOUT PRESSURE
SENSITIVE ADHESIVE
(PSA) RETENTION
STRAPS THERMAL
PADS FOUND
PART 3: RESTORATION-
-FIGURE 3Do a GVI of the affected
PSU Oxygen Generator
to determine if expended
and installation migration.
CONDITION 2: ANY PSU
OXYGEN GENERATOR
WITH PSA RETENTION
STRAPS THERMAL
PADS FOUND
FIGURE 13
-FIGURE 7(OPTION 1): Replace
PSA retention strap ther-
mal pads with non-PSA
retention strap thermal
pads and reposition affect-
ed PSU Oxygen Genera-
tor.
CONDITION 2.1: AFFECT-
ED PSU OXYGEN GEN-
ERATOR MIGRATION
FOUND AND NOT EX-
PENDED
FIGURE 9
PART 2: PASSENGER
COMPARTMENT AND
PSU CLOSE ACCESS
-
PART 3: RESTORATION-
-FIGURE 9(OPTION 2) (ACTION 1):
Reposition affected PSU
Oxygen Generator. PART 2: PASSENGERCOMPARTMENT AND
PSU CLOSE ACCESS
-
PART 3: RESTORATION-
PART 1: PASSENGER
COMPARTMENT AND
PSU ACCESS
-(OPTION 2) (ACTION 2):
Make sure affected PSU
Oxygen Generator migra-
tion is not found and has
not been expended. -FIGURE 3FIGURE 13
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
18 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 19

Group 2, Configuration 1:
Table 2: Passenger Service Unit (PSU) Oxygen Generator and Thermal Pad Inspection and Replacement
Refer to the listed proce-
dures in SB 737-35-1210
Original Issue or later
approved revisions as
an accepted procedure.
Method of ComplianceActionCondition
-FIGURE 7Replace PSA retention
strap thermal pads with
non-PSA retention strap
thermal pads.
CONDITION 2.1.1: AF-
FECTED PSU OXYGEN
GENERATOR MIGRA-
TION IS NOT FOUND
AND HAS NOT BEEN
FOUND EXPENDED
DURING (OPTION 2)
(ACTION 2)
PART 2: PASSENGER
COMPARTMENT AND
PSU CLOSE ACCESS
-
PART 3: RESTORATION-
-FIGURE 11CONDITION 2.1.2 (AC-
TION 1): Reposition affect-
ed PSU Oxygen Genera-
tor.
CONDITION 2.1.2: AF-
FECTED PSU OXYGEN
GENERATOR MIGRA-
TION IS FOUND AND
HAS NOT BEEN FOUND
EXPENDED DURING
(OPTION 2) (ACTION 2)
-FIGURE 11CONDITION 2.1.2 (AC-
TION 2): Replace PSA re-
tention strap thermal pads
with non-PSA retention
strap thermal pads.
PART 2: PASSENGER
COMPARTMENT AND
PSU CLOSE ACCESS
-
PART 3: RESTORATION-
-FIGURE 5CONDITION 2.1.3 (AC-
TION 1): Replace with
new or serviceable PSU
Oxygen Generator. (a)
CONDITION 2.1.3: AF-
FECTED PSU OXYGEN
GENERATOR HAS BEEN
FOUND EXPENDED
DURING (OPTION 2)
(ACTION 2) -FIGURE 5CONDITION 2.1.3 (AC-TION 2): Replace PSA re-
tention strap thermal pads
with non-PSA retention
strap thermal pads.
PART 2: PASSENGER
COMPARTMENT AND
PSU CLOSE ACCESS
-
PART 3: RESTORATION-
-FIGURE 5CONDITION 2.2 (ACTION
1): Replace with new or
serviceable PSU Oxygen
Generator. (a)
CONDITION 2.2: AFFECT-
ED PSU OXYGEN GEN-
ERATOR HAS BEEN EX-
PENDED
-FIGURE 5CONDITION 2.2 (ACTION
2): Replace PSA retention
strap thermal pads with
non-PSA retention strap
thermal pads.
PART 2: PASSENGER
COMPARTMENT AND
PSU CLOSE ACCESS
-
PART 3: RESTORATION-
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
19 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 20

Group 2, Configuration 1:
Table 2: Passenger Service Unit (PSU) Oxygen Generator and Thermal Pad Inspection and Replacement
Refer to the listed proce-
dures in SB 737-35-1210
Original Issue or later
approved revisions as
an accepted procedure.
Method of ComplianceActionCondition
-FIGURE 7Replace PSA retention
strap thermal pads with
non-PSA retention strap
thermal pads.
CONDITION 2.3: AFFECT-
ED PSU OXYGEN GEN-
ERATOR NOT EXPEND-
ED AND NO MIGRATION
FOUND
PART 2: PASSENGER
COMPARTMENT AND
PSU CLOSE ACCESS
-
PART 3: RESTORATION-
(a) A serviceable PSU Oxygen Generator is defined as a PSU Oxygen Generator that has not been expended
and has not expired (i.e., the PSU Oxygen Generator does not exceed the life limit established for that
generator by the manufacturer).
Group 1, Configuration 2:
Table 3: Passenger Service Unit (PSU) Oxygen Generator and Thermal Pad Inspection and Replacement
Refer to the listed proce-
dures in SB 737-35-1210
Original Issue or later
approved revisions as
an accepted procedure.
Method of ComplianceActionCondition
PART 1: PASSENGER
COMPARTMENT AND
PSU ACCESS
-Do a General Visual In-
spection (GVI) of the Pas-
senger Service Unit (PSU)
Oxygen Generator to de-
termine retention straps
thermal pads configura-
tion.
All Airplanes
-FIGURE 2
PART 2: PASSENGER
COMPARTMENT AND
PSU CLOSE ACCESS
-No further action is re-
quired.
CONDITION 1: ANY PSU
OXYGEN GENERATOR
WITHOUT PRESSURE
SENSITIVE ADHESIVE
(PSA) RETENTION
STRAPS THERMAL
PADS FOUND
PART 3: RESTORATION-
-FIGURE 4Do a GVI of the affected
PSU Oxygen Generator
to determine if expended.
CONDITION 2: ANY PSU
OXYGEN GENERATOR
WITH PSA RETENTION
STRAPS THERMAL
PADS FOUND
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
20 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 21

Group 1, Configuration 2:
Table 3: Passenger Service Unit (PSU) Oxygen Generator and Thermal Pad Inspection and Replacement
Refer to the listed proce-
dures in SB 737-35-1210
Original Issue or later
approved revisions as
an accepted procedure.
Method of ComplianceActionCondition
-FIGURE 6Replace with new or ser-
viceable PSU Oxygen
Generator and replace
PSA retention strap ther-
mal pads with non-PSA
retention strap thermal
pads. (a)
CONDITION 2.1: AFFECT-
ED PSU OXYGEN GEN-
ERATOR EXPENDED PART 2: PASSENGERCOMPARTMENT AND
PSU CLOSE ACCESS
-
PART 3: RESTORATION-
-FIGURE 8Replace PSA retention
strap thermal pads with
non-PSA retention strap
thermal pads.
CONDITION 2.2: AFFECT-
ED PSU OXYGEN GEN-
ERATOR NOT EXPEND-
ED
PART 2: PASSENGER
COMPARTMENT AND
PSU CLOSE ACCESS
-
PART 3: RESTORATION-
(a) A serviceable PSU Oxygen Generator is defined as a PSU Oxygen Generator that has not been expended
and has not expired (i.e., the PSU Oxygen Generator does not exceed the life limit established for that
generator by the manufacturer).
Group 2, Configuration 2:
Table 4: Passenger Service Unit (PSU) Oxygen Generator and Thermal Pad Inspection and Replacement
Refer to the listed proce-
dures in SB 737-35-1210
Original Issue or later
approved revisions as
an accepted procedure.
Method of ComplianceActionCondition
PART 1: PASSENGER
COMPARTMENT AND
PSU ACCESS
-Do a General Visual In-
spection (GVI) of the Pas-
senger Service Unit (PSU)
Oxygen Generator to de-
termine retention straps
thermal pads configura-
tion.
All Airplanes
-FIGURE 2
PART 2: PASSENGER
COMPARTMENT AND
PSU CLOSE ACCESS
-No further action is re-
quired.
CONDITION 1: ANY PSU
OXYGEN GENERATOR
WITHOUT PRESSURE
SENSITIVE ADHESIVE
(PSA) RETENTION
STRAPS THERMAL
PADS FOUND
PART 3: RESTORATION-
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
21 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 22

Group 2, Configuration 2:
Table 4: Passenger Service Unit (PSU) Oxygen Generator and Thermal Pad Inspection and Replacement
Refer to the listed proce-
dures in SB 737-35-1210
Original Issue or later
approved revisions as
an accepted procedure.
Method of ComplianceActionCondition
-FIGURE 4Do a GVI of the affected
PSU Oxygen Generator
to determine if expended
and installation migration.
CONDITION 2: ANY PSU
OXYGEN GENERATOR
WITH PSA RETENTION
STRAPS THERMAL
PADS FOUND
FIGURE 14
-FIGURE 8(OPTION 1): Replace
PSA retention strap ther-
mal pads with non-PSA
retention strap thermal
pads and reposition affect-
ed PSU Oxygen Genera-
tor.
CONDITION 2.1: AFFECT-
ED PSU OXYGEN GEN-
ERATOR MIGRATION
FOUND AND NOT EX-
PENDED
FIGURE 10
PART 2: PASSENGER
COMPARTMENT AND
PSU CLOSE ACCESS
-
PART 3: RESTORATION-
-FIGURE 10(OPTION 2) (ACTION 1):
Reposition affected PSU
Oxygen Generator. PART 2: PASSENGERCOMPARTMENT AND
PSU CLOSE ACCESS
-
PART 3: RESTORATION-
PART 1: PASSENGER
COMPARTMENT AND
PSU ACCESS
-(OPTION 2) (ACTION 2):
Make sure affected PSU
Oxygen Generator migra-
tion is not found and has
not been expended. -FIGURE 4FIGURE 14
-FIGURE 8Replace PSA retention
strap thermal pads with
non-PSA retention strap
thermal pads.
CONDITION 2.1.1: AF-
FECTED PSU OXYGEN
GENERATOR MIGRA-
TION IS NOT FOUND
AND HAS NOT BEEN
FOUND EXPENDED
DURING (OPTION 2)
(ACTION 2)
PART 2: PASSENGER
COMPARTMENT AND
PSU CLOSE ACCESS
-
PART 3: RESTORATION-
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
22 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 23

Group 2, Configuration 2:
Table 4: Passenger Service Unit (PSU) Oxygen Generator and Thermal Pad Inspection and Replacement
Refer to the listed proce-
dures in SB 737-35-1210
Original Issue or later
approved revisions as
an accepted procedure.
Method of ComplianceActionCondition
-FIGURE 12CONDITION 2.1.2 (AC-
TION 1): Reposition affect-
ed PSU Oxygen Genera-
tor.
CONDITION 2.1.2: AF-
FECTED PSU OXYGEN
GENERATOR MIGRA-
TION IS FOUND AND
HAS NOT BEEN FOUND
EXPENDED DURING
(OPTION 2) (ACTION 2)
-FIGURE 12CONDITION 2.1.2 (AC-
TION 2): Replace PSA re-
tention strap thermal pads
with non-PSA retention
strap thermal pads.
PART 2: PASSENGER
COMPARTMENT AND
PSU CLOSE ACCESS
-
PART 3: RESTORATION-
-FIGURE 6CONDITION 2.1.3 (AC-
TION 1): Replace with
new or serviceable PSU
Oxygen Generator. (a)
CONDITION 2.1.3: AF-
FECTED PSU OXYGEN
GENERATOR HAS BEEN
FOUND EXPENDED
DURING (OPTION 2)
(ACTION 2) -FIGURE 6CONDITION 2.1.3 (AC-TION 2): Replace PSA re-
tention strap thermal pads
with non-PSA retention
strap thermal pads.
PART 2: PASSENGER
COMPARTMENT AND
PSU CLOSE ACCESS
-
PART 3: RESTORATION-
-FIGURE 6CONDITION 2.2 (ACTION
1): Replace with new or
serviceable PSU Oxygen
Generator. (a)
CONDITION 2.2: AFFECT-
ED PSU OXYGEN GEN-
ERATOR HAS BEEN EX-
PENDED
-FIGURE 6CONDITION 2.2 (ACTION
2): Replace PSA retention
strap thermal pads with
non-PSA retention strap
thermal pads.
PART 2: PASSENGER
COMPARTMENT AND
PSU CLOSE ACCESS
-
PART 3: RESTORATION-
-FIGURE 8Replace PSA retention
strap thermal pads with
non-PSA retention strap
thermal pads.
CONDITION 2.3: AFFECT-
ED PSU OXYGEN GEN-
ERATOR NOT EXPEND-
ED AND NO MIGRATION
FOUND
PART 2: PASSENGER
COMPARTMENT AND
PSU CLOSE ACCESS
-
PART 3: RESTORATION-
(a) A serviceable PSU Oxygen Generator is defined as a PSU Oxygen Generator that has not been expended
and has not expired (i.e., the PSU Oxygen Generator does not exceed the life limit established for that
generator by the manufacturer).
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
23 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 24 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
This Figure applies only to: Group 1-2, Configuration 1.
PASSENGER
SERVICE
UNIT (PSU)
FWD
PASSENGER COMPARTMENT
(EXAMPLE)
3066110
FIGURE 1: PASSENGER COMPARTMENT - THERMAL PAD INSPECTION
(SHEET 1 OF 3)
Original Issue: June 17, 2024
Export Controlled ECCN: 9E991  737-35-1210 RB
See page 1 for details  24 of 68

### Page 25 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
OXYGEN
GENERATOR
PASSENGER
SERVICE  TEND
UNIT (PSU)
EXAMPLE - CORRECT STRAP AND THERMAL PAD INSTALLATION
OXYGEN
GENERATOR
PASSENGER
SERVICE
UNIT (PSU)
EXAMPLE - INCORRECT STRAP AND THERMAL PAD INSTALLATION
3066111
FIGURE 1: PASSENGER COMPARTMENT - THERMAL PAD INSPECTION
(SHEET 2 OF 3)
Original Issue: June 17, 2024
737-35-1210 RB
Export Controlled ECCN: 9E991
See page 1 for details  25 of 68

### Page 26

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a) 253010 OR 69848THERMAL PADInspect1
(a)
Do a General Visual Inspection (GVI) of the PSU Oxygen Generator thermal pad to determine the type
of thermal pad installed under the retention strap.
FIGURE 1: PASSENGER COMPARTMENT - THERMAL PAD INSPECTION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
26 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 27 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
This Figure applies only to: Group 1-2, Configuration 2.
PASSENGER
SERVICE
UNIT (PSU)
FWD
PASSENGER COMPARTMENT
(EXAMPLE
3066282
FIGURE 2: PASSENGER COMPARTMENT - THERMAL PAD INSPECTION
(SHEET 1 OF 3)
Original Issue: June 17, 2024
737-35-1210 RB
Export Controlled ECCN: 9E991
See page 1 for details  27 of 68

### Page 28 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
OXYGEN
GENERATOR
PASSENGER
SERVICE
UNIT (PSU)
EXAMPLE - CORRECT STRAP AND THERMAL PAD INSTALLATION
OXYGEN
GENERATOR
PASSENGER
SERVICE
UNIT (PSU)
EXAMPLE - INCORRECT STRAP AND THERMAL PAD INSTALLATION
3066283
FIGURE 2: PASSENGER COMPARTMENT - THERMAL PAD INSPECTION
(SHEET 2 OF 3)
Original Issue: June 17, 2024
Export Controlled ECCN: 9E991  737-35-1210 RB
See page 1 for details  28 0f 68

### Page 29

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a) 273667 OR 69762THERMAL PADInspect1
(a)
Do a General Visual Inspection (GVI) of the PSU Oxygen Generator thermal pad to determine the type
of thermal pad installed under the retention strap.
FIGURE 2: PASSENGER COMPARTMENT - THERMAL PAD INSPECTION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
29 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 30 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
This Figure applies only to: Group 1-2, Configuration 1.
PASSENGER
SERVICE
UNIT (PSU)
FWD
PASSENGER COMPARTMENT
(EXAMPLE)
3066112
FIGURE 3: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
EXPENDED INSPECTION
(SHEET 1 OF 3)
Original Issue: June 17, 2024
737-35-1210 RB
Export Controlled ECCN: 9E991
See page 1 for details  30 of 68

### Page 31 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
OXYGEN
GENERATOR
PASSENGER
SERVICE
UNIT (PSU)
3066113
FIGURE 3: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
EXPENDED INSPECTION
(SHEET 2 OF 3)
Original Issue: June 17, 2024
Export Controlled ECCN: 9E991  737-35-1210 RB
See page 1 for details  31 of 68

### Page 32

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a) 1E71740-00 OR
S417T401-44
OXYGEN GENERA-
TOR (12-MIN.)
Inspect1
(a)
Do a General Visual Inspection (GVI) of the affected PSU Oxygen Generator to determine if expended
as shown in APPENDIX D and APPENDIX E.
FIGURE 3: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
EXPENDED INSPECTION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
32 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 33 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
This Figure applies only to: Group 1-2, Configuration 2.
PASSENGER
SERVICE
UNIT (PSU)
PASSENGER COMPARTMENT
(EXAMPLE
3067068
FIGURE 4: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
EXPENDED INSPECTION
(SHEET 1 OF 3)
Original Issue: June 17, 2024
Export Controlled ECCN: 9E991  737-35-1210 RB
See page 1 for details  33 of 68

### Page 34 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
OXYGEN
GENERATOR
PASSENGER
SERVICE
UNIT (PSU)
3067069
FIGURE 4: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
EXPENDED INSPECTION
(SHEET 2 OF 3)
Original Issue: June 17, 2024
737-35-1210 RB
Export Controlled ECCN: 9E991
See page 1 for details  34 of 68

### Page 35

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a) 1E72280-00 OR
S417T401-63
OXYGEN GENERA-
TOR (22-MIN.)
Inspect1
(a)
Do a General Visual Inspection (GVI) of the affected PSU Oxygen Generator to determine if expended
as shown in APPENDIX D and APPENDIX E.
FIGURE 4: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
EXPENDED INSPECTION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
35 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 36 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
This Figure applies only to: Group 1-2, Configuration 1.
PASSENGER
SERVICE
UNIT (PSU)
FWD
PASSENGER COMPARTMENT
(EXAMPLE)
3066280
FIGURE 5: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR AND
THERMAL PAD REPLACEMENT
(SHEET 1 OF 3)
Original Issue: June 17, 2024
737-35-1210 RB
Export Controlled ECCN: 9E991
See page 1 for details  36 of 68

### Page 37 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
PASSENGER
SERVICE
UNIT (PSU)
PASSENGER
SERVICE
UNIT (PSU)
FIGURE 5: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR AND
THERMAL PAD REPLACEMENT
(SHEET 2 OF 3)
Original Issue: June 17, 2024
737-35-1210 RB
Export Controlled ECCN: 9E991
See page 1 for details  37 of 68

### Page 38

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
IF THE CHEMICAL OXYGEN GENERATOR ACCIDENTALLY OPERATES, IT IS MANDATORY
THAT YOU REPLACE IT. AN EXPENDED OXYGEN GENERATOR GETS VERY HOT (450
DEG. FAHRENHEIT/232 DEG. CELSIUS) OR HIGHER AND CAN BURN YOU IF YOU TOUCH
IT. YOU MUST NOT TOUCH THE OXYGEN GENERATOR UNTIL IT BECOMES COOL.WARNING
More DataQtyIdentificationNameTaskStep
(a)(c)(g)2NAS1301-6-10SCREWRemove / Keep1
(a)(b)(c)(g)253010THERMAL PADRemove2
(d) 1E71740-00 OR
S417T401-44
OXYGEN GENERA-
TOR (12-MIN.)
Remove
(d) 1E71740-00 OR
S417T401-44
OXYGEN GENERA-
TOR (12-MIN.)
Install (New)3
(e)(f)(g)269848THERMAL PADInstall (New)
(g) 2NAS1301-6-10SCREWInstall (Kept)4
(h) 2NAS1301-6-10SCREWTorque5
(a) Remove one screw and one retention strap at a time. Make sure that when one screw and one retention
strap are removed, the other screw and retention strap are securing the PSU Oxygen Generator.
(b)
Clean the retention strap.
(c) After first screw and retention strap are removed, remove the second screw and retention strap. This is
required when the PSU Oxygen Generator has been expended.
(d) If the PSU Oxygen Generator has been expended, replace the PSU Oxygen Generator with a new or
serviceable PSU Oxygen Generator. Refer to 737-7/8/8200/9/10 AMM 35-22-11 as an accepted procedure.
(e) Install the non-PSA thermal pad onto the retention strap.
Note: The open portion of the thermal pad will face away from the PSU Oxygen Generator.
(f) Install the retention strap and thermal pad back onto the PSU.
(g) Repeat for the second retention strap if required.
(h) Torque screw 8-10 in-lbs.
FIGURE 5: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR AND
THERMAL PAD REPLACEMENT
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
38 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 39 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
This Figure applies only to: Group 1-2, Configuration 2.
PASSENGER
SERVICE
UNIT (PSU)
PASSENGER COMPARTMENT
(EXAMPLE)
3066805
FIGURE 6: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR AND
THERMAL PAD REPLACEMENT
(SHEET 1 OF 3)
Original Issue: June 17, 2024
Export Controlled ECCN: 9E991  737-35-1210 RB
See page 1 for details  39 of 68

### Page 40 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
PASSENGER
SERVICE
UNIT (PSU)
PASSENGER
SERVICE
UNIT (PSU)  FY
3066804
FIGURE 6: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR AND
THERMAL PAD REPLACEMENT
(SHEET 2 OF 3)
Original Issue: June 17, 2024
737-35-1210 RB
Export Controlled ECCN: 9E991
See page 1 for details  40 of 68

### Page 41

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
IF THE CHEMICAL OXYGEN GENERATOR ACCIDENTALLY OPERATES, IT IS MANDATORY
THAT YOU REPLACE IT. AN EXPENDED OXYGEN GENERATOR GETS VERY HOT (450
DEG. FAHRENHEIT/232 DEG. CELSIUS) OR HIGHER AND CAN BURN YOU IF YOU TOUCH
IT. YOU MUST NOT TOUCH THE OXYGEN GENERATOR UNTIL IT BECOMES COOL.WARNING
More DataQtyIdentificationNameTaskStep
(a)(c)(g)2NAS1301-6-10SCREWRemove / Keep1
(a)(b)(c)(g)273667THERMAL PADRemove2
(d) 1E72280-00 OR
S417T401-63
OXYGEN GENERA-
TOR (22-MIN.)
Remove
(d) 1E72280-00 OR
S417T401-63
OXYGEN GENERA-
TOR (22-MIN.)
Install (New)3
(e)(f)(g)269762THERMAL PADInstall (New)
(g) 2NAS1301-6-10SCREWInstall (Kept)4
(h) 2NAS1301-6-10SCREWTorque5
(a) Remove one screw and one retention strap at a time. Make sure that when one screw and one retention
strap are removed, the other screw and retention strap are securing the PSU Oxygen Generator.
(b)
Clean the retention strap.
(c) After first screw and retention strap are removed, remove the second screw and retention strap. This is
required when the PSU Oxygen Generator has been expended.
(d) If the PSU Oxygen Generator has been expended, replace the PSU Oxygen Generator with a new or
serviceable PSU Oxygen Generator. Refer to 737-7/8/8200/9/10 AMM 35-22-11 as an accepted procedure.
(e) Install the non-PSA thermal pad onto the retention strap.
Note: The open portion of the thermal pad will face away from the PSU Oxygen Generator.
(f) Install the retention strap and thermal pad back onto the PSU.
(g) Repeat for the second retention strap if required.
(h) Torque screw 8-10 in-lbs.
FIGURE 6: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR AND
THERMAL PAD REPLACEMENT
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
41 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 42 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
This Figure applies only to: Group 1-2, Configuration 1.
PASSENGER
SERVICE
UNIT (PSU)
FWD
PASSENGER COMPARTMENT
(EXAMPLE)
3067674
FIGURE 7: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR THERMAL
PAD REPLACEMENT
(SHEET 1 OF 3)
Original Issue: June 17, 2024
737-35-1210 RB
Export Controlled ECCN: 9E991
See page 1 for details  42 of 68

### Page 43 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
PASSENGER
SERVICE
UNIT (PSU)
PASSENGER
SERVICE
UNIT (PSU)
3067676
FIGURE 7: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR THERMAL
PAD REPLACEMENT
(SHEET 2 OF 3)
Original Issue: June 17, 2024
737-35-1210 RB
Export Controlled ECCN: 9E991
See page 1 for details  43 of 68

### Page 44

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)(e)2NAS1301-6-10SCREWRemove / Keep1
(a)(b)(e)253010THERMAL PADRemove
(c)(d)(e)269848THERMAL PADInstall (New)2
(e) 2NAS1301-6-10SCREWInstall (Kept)
(f) 2NAS1301-6-10SCREWTorque3
(a) Remove one screw and one retention strap at a time. Make sure that when one screw and one retention
strap are removed, the other screw and retention strap are securing the PSU Oxygen Generator.
(b)
Clean the retention strap.
(c) Install the non-PSA thermal pad onto the retention strap.
Note: The open portion of the thermal pad will face away from the PSU Oxygen Generator.
(d) Install the retention strap and thermal pad back onto the PSU.
(e) Repeat for the second retention strap if required.
(f) Torque screw 8-10 in-lbs.
FIGURE 7: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR THERMAL
PAD REPLACEMENT
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
44 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 45 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
This Figure applies only to: Group 1-2, Configuration 2.
•PASSENGER
SERVICE
UNIT (PSU)
PASSENGER COMPARTMENT
(EXAMPLE
3067678
FIGURE 8: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR THERMAL
PAD REPLACEMENT
(SHEET 1 OF 3)
Original Issue: June 17, 2024
737-35-1210 RB
Export Controlled ECCN: 9E991
See page 1 for details  45 of 68

### Page 46 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
PASSENGER
SERVICE
UNIT (PSU)
PASSENGER
SERVICE
UNIT (PSU)
3067680
FIGURE 8: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR THERMAL
PAD REPLACEMENT
(SHEET 2 OF 3)
Original Issue: June 17, 2024
Export Controlled ECCN: 9E991  737-35-1210 RB
See page 1 for details  46 of 68

### Page 47

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)(e)2NAS1301-6-10SCREWRemove / Keep1
(a)(b)(e)273667THERMAL PADRemove
(c)(d)(e)269762THERMAL PADInstall (New)2
(f) 2NAS1301-6-10SCREWInstall (Kept)
(a) Remove one screw and one retention strap at a time. Make sure that when one screw and one retention
strap are removed, the other screw and retention strap are securing the PSU Oxygen Generator.
(b)
Clean the retention strap.
(c) Install the non-PSA thermal pad onto the retention strap.
Note: The open portion of the thermal pad will face away from the PSU Oxygen Generator.
(d) Install the retention strap and thermal pad back onto the PSU.
(e) Repeat for the second retention strap if required.
(f) Torque screw 8-10 in-lbs.
FIGURE 8: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR THERMAL
PAD REPLACEMENT
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
47 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 48 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
This Figure applies only to: Group 2, Configuration 1.
PASSENGER
SERVICE
UNIT (PSU)
FWD
PASSENGER COMPARTMENT
(EXAMPLE)
3067682
FIGURE 9: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
REPOSITION
(SHEET 1 OF 3)
Original Issue: June 17, 2024
737-35-1210 RB
Export Controlled ECCN: 9E991
See page 1 for details  48 of 68

### Page 49 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
PASSENGER
SERVICE
UNIT (PSU)
3067684
FIGURE 9: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
REPOSITION
(SHEET 2 OF 3)
Original Issue: June 17, 2024
Export Controlled ECCN: 9E991  737-35-1210 RB
See page 1 for details  49 of 68

### Page 50

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
IF THE CHEMICAL OXYGEN GENERATOR ACCIDENTALLY OPERATES, IT IS MANDATORY
THAT YOU REPLACE IT. AN EXPENDED OXYGEN GENERATOR GETS VERY HOT (450
DEG. FAHRENHEIT/232 DEG. CELSIUS) OR HIGHER AND CAN BURN YOU IF YOU TOUCH
IT. YOU MUST NOT TOUCH THE OXYGEN GENERATOR UNTIL IT BECOMES COOL.WARNING
More DataQtyIdentificationNameTaskStep
(a)(b)2NAS1301-6-10SCREWLoosen1
(b) 1E71740-00 OR
S417T401-44
OXYGEN GENERA-
TOR (12-MIN.)
Move2
(c) 2NAS1301-6-10SCREWTorque3
(a)
Loosen but do not remove the 2 screws.
(b) Loosen screws to reposition the PSU Oxygen Generator by moving it into contact with the oxygen mask
box. Refer to APPENDIX H for guidance.
(c) Torque screw 8-10 in-lbs.
FIGURE 9: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
REPOSITION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
50 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 51 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
This Figure applies only to: Group 2, Configuration 2.
PASSENGER
SERVICE
UNIT (PSU)
PASSENGER COMPARTMENT
(EXAMPLE
3067686
FIGURE 10: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
REPOSITION
(SHEET 1 OF 3)
Original Issue: June 17, 2024
Export Controlled ECCN: 9E991  737-35-1210 RB
See page 1 for details  51 of 68

### Page 52 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
PASSENGER
SERVICE
UNIT (PSU)
3067688
FIGURE 10: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
REPOSITION
(SHEET 2 OF 3)
Original Issue: June 17, 2024
737-35-1210 RB
Export Controlled ECCN: 9E991
See page 1 for details  52 of 68

### Page 53

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
IF THE CHEMICAL OXYGEN GENERATOR ACCIDENTALLY OPERATES, IT IS MANDATORY
THAT YOU REPLACE IT. AN EXPENDED OXYGEN GENERATOR GETS VERY HOT (450
DEG. FAHRENHEIT/232 DEG. CELSIUS) OR HIGHER AND CAN BURN YOU IF YOU TOUCH
IT. YOU MUST NOT TOUCH THE OXYGEN GENERATOR UNTIL IT BECOMES COOL.WARNING
More DataQtyIdentificationNameTaskStep
(a)(b)2NAS1301-6-10SCREWLoosen1
(b) 1E72280-00 OR
S417T401-63
OXYGEN GENERA-
TOR (22-MIN.)
Move2
(c) 2NAS1301-6-10SCREWTorque3
(a)
Loosen but do not remove the 2 screws.
(b) Loosen screws to reposition the PSU Oxygen Generator by moving it into contact with the oxygen mask
box. Refer to APPENDIX H for guidance.
(c) Torque screw 8-10 in-lbs.
FIGURE 10: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
REPOSITION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
53 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 54 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
This Figure applies only to: Group 2, Configuration 1.
PASSENGER
SERVICE
UNIT (PSU)
FWD
PASSENGER COMPARTMENT
(EXAMPLE)
3067691
FIGURE 11: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
REPOSITION AND THERMAL PAD REPLACEMENT
(SHEET 1 OF 3)
Original Issue: June 17, 2024
Export Controlled ECCN: 9E991  737-35-1210 RB
See page 1 for details  54 of 68

### Page 55 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
134
PASSENGER
SERVICE
UNIT (PSU)
PASSENGER
SERVICE
UNIT (PSU)
3067693
FIGURE 11: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
REPOSITION AND THERMAL PAD REPLACEMENT
(SHEET 2 OF 3)
Original Issue: June 17, 2024
Export Controlled ECCN: 9E991  737-35-1210 RB
See page 1 for details  55 of 68

### Page 56

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
IF THE CHEMICAL OXYGEN GENERATOR ACCIDENTALLY OPERATES, IT IS MANDATORY
THAT YOU REPLACE IT. AN EXPENDED OXYGEN GENERATOR GETS VERY HOT (450
DEG. FAHRENHEIT/232 DEG. CELSIUS) OR HIGHER AND CAN BURN YOU IF YOU TOUCH
IT. YOU MUST NOT TOUCH THE OXYGEN GENERATOR UNTIL IT BECOMES COOL.WARNING
More DataQtyIdentificationNameTaskStep
(a)(b)2NAS1301-6-10SCREWLoosen1
(b) 1E71740-00 OR
S417T401-44
OXYGEN GENERA-
TOR (12-MIN.)
Move2
2NAS1301-6-10SCREWTighten3
(c)(g) 2NAS1301-6-10SCREWRemove / Keep4
(c)(d)(g)253010THERMAL PADRemove
(e)(f)(g)269848THERMAL PADInstall (New)5
(g) 2NAS1301-6-10SCREWInstall (Kept)
(h) 2NAS1301-6-10SCREWTorque6
(a)
Loosen but do not remove the 2 screws.
(b) Loosen screws to reposition the PSU Oxygen Generator by moving it into contact with the oxygen mask
box. Refer to APPENDIX H for guidance.
(c) Remove one screw and one retention strap at a time. Make sure that when one screw and one retention
strap are removed, the other screw and retention strap are securing the PSU Oxygen Generator.
(d) Clean the retention strap.
(e) Install the non-PSA thermal pad onto the retention strap.
Note: The open portion of the thermal pad will face away from the PSU Oxygen Generator.
(f) Install the retention strap and thermal pad back onto the PSU.
(g) Repeat for the second retention strap if required.
(h) Torque screw 8-10 in-lbs.
FIGURE 11: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
REPOSITION AND THERMAL PAD REPLACEMENT
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
56 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 57 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
This Figure applies only to: Group 2, Configuration 2.
PASSENGER
SERVICE
UNIT (PSU)
PASSENGER COMPARTMENT
(EXAMPLE)
3067695
FIGURE 12: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
REPOSITION AND THERMAL PAD REPLACEMENT
(SHEET 1 OF 3)
Original Issue: June 17, 2024
Export Controlled ECCN: 9E991  737-35-1210 RB
See page 1 for details  57 of 68

### Page 58 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
1) 3)4
PASSENGER
SERVICE
UNIT (PSU)
PASSENGER
SERVICE
UNIT (PSU)
3067697
FIGURE 12: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
REPOSITION AND THERMAL PAD REPLACEMENT
(SHEET 2 OF 3)
Original Issue: June 17, 2024
737-35-1210 RB
Export Controlled ECCN: 9E991
See page 1 for details  58 of 68

### Page 59

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
IF THE CHEMICAL OXYGEN GENERATOR ACCIDENTALLY OPERATES, IT IS MANDATORY
THAT YOU REPLACE IT. AN EXPENDED OXYGEN GENERATOR GETS VERY HOT (450
DEG. FAHRENHEIT/232 DEG. CELSIUS) OR HIGHER AND CAN BURN YOU IF YOU TOUCH
IT. YOU MUST NOT TOUCH THE OXYGEN GENERATOR UNTIL IT BECOMES COOL.WARNING
More DataQtyIdentificationNameTaskStep
(a)(b)2NAS1301-6-10SCREWLoosen1
(b) 1E72280-00 OR
S417T401-63
OXYGEN GENERA-
TOR (22-MIN.)
Move2
2NAS1301-6-10SCREWTighten3
(c)(g) 2NAS1301-6-10SCREWRemove / Keep4
(c)(d)(g)273667THERMAL PADRemove
(e)(f)(g)269762THERMAL PADInstall (New)5
(g) 2NAS1301-6-10SCREWInstall (Kept)
(h) 2NAS1301-6-10SCREWTorque6
(a)
Loosen but do not remove the 2 screws.
(b) Loosen screws to reposition the PSU Oxygen Generator by moving it into contact with the oxygen mask
box. Refer to APPENDIX H for guidance.
(c) Remove one screw and one retention strap at a time. Make sure that when one screw and one retention
strap are removed, the other screw and retention strap are securing the PSU Oxygen Generator.
(d) Clean the retention strap.
(e) Install the non-PSA thermal pad onto the retention strap.
Note: The open portion of the thermal pad will face away from the PSU Oxygen Generator.
(f) Install the retention strap and thermal pad back onto the PSU.
(g) Repeat for the second retention strap if required.
(h) Torque screw 8-10 in-lbs.
FIGURE 12: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR
REPOSITION AND THERMAL PAD REPLACEMENT
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: June 17, 2024
737-35-1210 RB
59 of 68
REQUIREMENTS BULLETIN 737-35-1210

### Page 60 (OCR)

REQUIREMENTS BULLETIN 737-35-1210
This Figure applies only to: Group 2, Configuration 1.
PASSENGER
SERVICE
UNIT (PSU)
FWD
PASSENGER COMPARTMENT
(EXAMPLE)
3067699
FIGURE 13: PASSENGER COMPARTMENT - PASSENGER SERVICE UNIT OXYGEN GENERATOR POSITION
INSPECTION
(SHEET 1 OF 3)
Original Issue: June 17, 2024
737-35-1210 RB
Export Controlled ECCN: 9E991
See page 1 for details  60 of 68

The text continues at https://openairdocs.org/service-documents/boeing/737-35-1210-rb/file/408dcad25583.md?from=61

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.