### Page 145

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14L, STA 787 TO
STA 908
SKIN - LAP SPLICEInspect1
(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fas-
tener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.
Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure
9.
FIGURE 7: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY EDDY
CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
145 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 146 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 3, Configuration 1.
STA
727
STA  STA
847  747
STA
1016
S-1
0000000800000000  S-14R
FWD  FRAME
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
INSPECTION AREA  2851026
FIGURE 8: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY EDDY
CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  146 of 227

### Page 147

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 747 TO
STA 847
SKIN - LAP SPLICEInspect1
(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fas-
tener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.
Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure
9.
FIGURE 8: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY EDDY
CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
147 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 148 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 6, Configuration 2-3.
STA
1016
STA
727
STA
727G
STA
1016
S-1
- S-14L
FWD
FRAME
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
A INSPECTION AREA  2851021
FIGURE 9: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY EDDY
CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  148 of 227

### Page 149

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14L, STA 727A TO
STA 727G
SKIN - LAP SPLICEInspect1
(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fas-
tener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.
Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure
9.
FIGURE 9: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY EDDY
CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
149 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 150 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 4.
STA  STA
787  727A
STA
1016
S-1
900000000008000
- S-14R
FRAME
FWD
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
INSPECTION AREA  2851027
FIGURE 10: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  150 of 227

### Page 151

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 727A TO
STA 787
SKIN - LAP SPLICEInspect1
(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fas-
tener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.
Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure
9.
FIGURE 10: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
151 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 152 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 6, Configuration 1.
STA
1016
STA
727
STA
1016
S-1
0000  - S-14L
WD
FRAME
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
/A INSPECTION AREA  2851020
FIGURE 11: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  152 of 227

### Page 153

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14L, STA 727A TO
STA 827
SKIN - LAP SPLICEInspect1
(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fas-
tener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.
Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure
9.
FIGURE 11: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
153 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 154 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 4-5.
STA  STA
908  787
STA
1016
000098000000  S-14R
FWD  FRAME
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER•
TYPICAL SKIN LAP SPLICE
INSPECTION AREA  2851028
FIGURE 12: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  154 of 227

### Page 155

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 787 TO
STA 908
SKIN - LAP SPLICEInspect1
(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fas-
tener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.
Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure
9.
FIGURE 12: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
155 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 156 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 7.
STA
1016
STA
727
i Does
SZTA
SIZA  STA
1016
S-1
000000  - S-14L
WD
FRAME
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
/A INSPECTION AREA  2851019
FIGURE 13: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  156 of 227

### Page 157

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14L, STA 727A TO
STA 908
SKIN - LAP SPLICEInspect1
(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fas-
tener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.
Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure
9.
FIGURE 13: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
157 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 158 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 6, Configuration 2-3.
STA
727
STA
STA
1016  727
- S-1
000000000000200000  - S-14R
FRAME
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
INSPECTION AREA  2851022
FIGURE 14: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  158 of 227

### Page 159

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 727A TO
STA 727G
SKIN - LAP SPLICEInspect1
(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fas-
tener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.
Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure
9.
FIGURE 14: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
159 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 160 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 8.
STA
1016
STA
727
STA  STA
727G  908
STA  STA
727  1016
S-1
000000  - S-14L
WD
FRAME
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
/A INSPECTION AREA  2835341
FIGURE 15: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  160 of 227

### Page 161

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14L, STA 727G TO
STA 908
SKIN - LAP SPLICEInspect1
(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fas-
tener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.
Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure
9.
FIGURE 15: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
161 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 162 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 6, Configuration 1.
STA
727
STA
847
STA  STA
1016  727
- S-1
000000000000200000  - S-14R
FRAME
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
INSPECTION AREA  2851023
FIGURE 16: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  162 of 227

### Page 163

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 727A TO
STA 847
SKIN - LAP SPLICEInspect1
(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fas-
tener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.
Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure
9.
FIGURE 16: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
163 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 164 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 9, Configuration 1; Group 10.
STA
1016
STA
727
<2b 1 e00l
STA  STA
727A  827
STA
1016
000000000  - S-14L
FRAME
FWD
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
/A INSPECTION AREA  2835342
FIGURE 17: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  164 of 227

### Page 165

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14L, STA 727A TO
STA 827
SKIN - LAP SPLICEInspect1
(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fas-
tener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.
Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure
9.
FIGURE 17: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
165 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 166 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 7.
STA
727
0000 30
STA
806
STA  STA
1016  727
- S-1
000000000000300000  - S-14R
FRAME
FWD
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
INSPECTION AREA  2851024
FIGURE 18: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  166 of 227

### Page 167

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 727A TO
STA 908
SKIN - LAP SPLICEInspect1
(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fas-
tener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.
Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure
9.
FIGURE 18: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
167 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 168 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 10.
STA
1016
STA
727
220 1 800
STA  STA
727  1016
S-1
0000000000  • S-14L
FRAME
FWD
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
/A INSPECTION AREA  2850818
FIGURE 19: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  168 of 227

### Page 169

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14L, STA 827 TO
STA 908
SKIN - LAP SPLICEInspect1
(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fas-
tener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.
Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure
9.
FIGURE 19: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
169 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 170 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 8.
STA
727
000] 2)
STA  STA
908  727G
STA  STA
1016  727
S-1
000000000000000000  - S-14R
FRAME
FWD
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
INSPECTION AREA  2851025
FIGURE 20: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  170 of 227

### Page 171

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 727G TO
STA 908
SKIN - LAP SPLICEInspect1
(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fas-
tener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.
Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure
9.
FIGURE 20: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
171 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 172 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 1, Configuration 1.
STA
1016
STA
727
* 1000
STA
727
- S-1
000000000  - S-14L
FRAME  WD
UPPER SKIN
LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
• INSPECTION AREA
2851555
FIGURE 21: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  172 of 227

### Page 173

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14L, STA 727 TO
STA 827
SKIN - LAP SPLICEInspect1
(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower
fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.
Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean
up hole for open hole HFEC inspection.
FIGURE 21: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
173 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 174 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 9, Configuration 1.
STA
1016
STA
727
STA
847  27A
STA  ISTA
1016  727
- S-1
0000000000000
- S-14R
FRAME
FWD
UPPER SKIN
LOWER SKIN
TYPICAL CRACK
STRINGER-
TYPICAL SKIN LAP SPLICE
INSPECTION AREA  2850935
FIGURE 22: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  174 of 227

### Page 175

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 727A TO
STA 847
SKIN - LAP SPLICEInspect1
(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fas-
tener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.
Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure
9.
FIGURE 22: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
175 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 176 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 2-3, 11, Configuration 1.
STA
1016
STA
727
STA  STA
727A  827
6 10000  STA  727  STA  908  1016  STA
7-S-1
00000  00000  S-14L
FRAME
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
A INSPECTION AREA  2851556
FIGURE 23: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  176 of 227

### Page 177

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14L, STA 727A TO
STA 827
SKIN - LAP SPLICEInspect1
(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower
fastener row holes for any crack in accordance with 737 NDT Manual Part 6, 51-00-00, Procedure 16.
Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean
up hole for open hole HFEC inspection.
FIGURE 23: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
177 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 178 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 10.
STA
1016
STA
727
STA
787
STA  ISTA
1016  727
- S-1
0000000000000
- S-14R
FRAME
FWD
UPPER SKIN
LOWER SKIN
TYPICAL CRACK
STRINGER-
TYPICAL SKIN LAP SPLICE
INSPECTION AREA  2850974
FIGURE 24: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  178 of 227

### Page 179

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 727A TO
STA 787
SKIN - LAP SPLICEInspect1
(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fas-
tener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.
Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure
9.
FIGURE 24: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
179 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 180 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 4.
STA
1016
STA
727
A Dose  STA
727A
STA
1016
S-1
000000000  - S-14L
FWD
FRAME
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
A INSPECTION AREA  2851557
FIGURE 25: SECTION 46 - SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH
FREQUENCY EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  180 of 227

### Page 181

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14L, STA 727A TO
STA 787
SKIN - LAP SPLICEInspect1
(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower
fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.
Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean
up hole for open hole HFEC inspection.
FIGURE 25: SECTION 46 - SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH
FREQUENCY EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
181 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 182 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 10.
STA
1016
STA
727
STA  STA
908  787
STA
1016
- S-1
0000090000000
- S-14R
FRAME
FWD
UPPER SKIN
LOWER SKIN
TYPICAL CRACK
STRINGER-
TYPICAL SKIN LAP SPLICE
INSPECTION AREA  2850977
FIGURE 26: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  182 of 227

### Page 183

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 787 TO
STA 908
SKIN - LAP SPLICEInspect1
(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fas-
tener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.
Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure
9.
FIGURE 26: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
183 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 184 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 4-5.
STA
1016
STA
727
STA  STA
787  908
STA  STA
1016
S-1
0000009000000  -S-14L
FRAME
•
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
/A INSPECTION AREA  2851558
FIGURE 27: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  184 of 227

### Page 185

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14L, STA 787 TO
STA 908
SKIN - LAP SPLICEInspect1
(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower
fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.
Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean
up hole for open hole HFEC inspection.
FIGURE 27: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
185 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 186 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 11, Configuration 1.
STA
727
STA  STA
847  727A
STA
1016
000  0000000000000
- S-14R
FRAME
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER•
TYPICAL SKIN LAP SPLICE
INSPECTION AREA  2850784
FIGURE 28: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  186 of 227

### Page 187

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 727A TO
STA 847
SKIN - LAP SPLICEInspect1
(a) Do the external Dual Frequency Eddy Curent Inspection of the lower skin along the lap splice lower fas-
tener row for any crack, in accordance with 737 NDT Manual Part 6, 53-30-00 Procedure 9.
Do not do the contingent open hole inspection specified in 737 NDT Manual Part 6, 53-30-00 Procedure
9.
FIGURE 28: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - EXTERNAL DUAL FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
187 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 188 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 6, Configuration 2-3.
STA
1016
STA
727
STA
727G
STA
1016
S-1
- S-14L
FWD
FRAME
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
/A INSPECTION AREA  2851559
FIGURE 29: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  188 of 227

### Page 189

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14L, STA 727A TO
STA 727G
SKIN - LAP SPLICEInspect1
(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower
fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.
Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean
up hole for open hole HFEC inspection.
FIGURE 29: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
189 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 190 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 1, Configuration 1.
STA
1016
STA
727
STA
STA  827
1016
S-1
S-14R -  000000000
FRAME
FWD
UPPER SKIN
LOWER SKIN
TYPICAL CRACK
STRINGER•
TYPICAL SKIN LAP SPLICE
/ INSPECTION AREA
2851566
FIGURE 30: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  190 of 227

### Page 191

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 727 TO
STA 827
SKIN - LAP SPLICEInspect1
(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower
fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.
Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean
up hole for open hole HFEC inspection.
FIGURE 30: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
191 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 192 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 6, Configuration 1.
STA
1016
STA
727
STA
1016
S-1
0000  - S-14L
WD
FRAME
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
/A INSPECTION AREA  2851560
FIGURE 31: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  192 of 227

### Page 193

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14L, STA 727A TO
STA 827
SKIN - LAP SPLICEInspect1
(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower
fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.
Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean
up hole for open hole HFEC inspection.
FIGURE 31: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
193 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 194 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 2, Configuration 1.
STA  STA
827  727A
STA  STA
1016  727
S-1
0000000000002000  - S-14R
FWD  FRAME
UPPER SKIN
LOWER SKIN
TYPICAL CRACK
STRINGER-
TYPICAL SKIN LAP SPLICE
INSPECTION AREA  2851567
FIGURE 32: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  194 of 227

### Page 195

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 727A TO
STA 827
SKIN - LAP SPLICEInspect1
(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower
fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.
Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean
up hole for open hole HFEC inspection.
FIGURE 32: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
195 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 196 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 7.
STA
1016
STA
727
i Does
SZTA
SIZA  STA
1016
S-1
000000  - S-14L
WD
FRAME
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
A INSPECTION AREA  2851561
FIGURE 33: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  196 of 227

### Page 197

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14L, STA 727A TO
STA 908
SKIN - LAP SPLICEInspect1
(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower
fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.
Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean
up hole for open hole HFEC inspection.
FIGURE 33: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
197 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 198 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 3, Configuration 1.
STA  STA
747  727A
STA
1016
000003000  - S-14R
FRAME
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
INSPECTION AREA  2851571
FIGURE 34: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  198 of 227

### Page 199

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 727A TO
STA 747
SKIN - LAP SPLICEInspect1
(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower
fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.
Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean
up hole for open hole HFEC inspection.
FIGURE 34: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
199 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 200 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 8.
STA
1016
STA
727
STA  STA
727G  908
STA  STA
727  1016
S-1
000000  - S-14L
WD
FRAME
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
A INSPECTION AREA  2851562
FIGURE 35: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  200 of 227

### Page 201

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14L, STA 727G TO
STA 908
SKIN - LAP SPLICEInspect1
(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower
fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.
Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean
up hole for open hole HFEC inspection.
FIGURE 35: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
201 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 202 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 3, Configuration 1.
STA
727
STA  STA
847  747
STA
1016
S-1
0000000800000000  S-14R
FWD  FRAME
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
INSPECTION AREA  2851572
FIGURE 36: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  Copyright © Unpublished  737-53A1382 RB
Work - See page 1 for details.  202 of 227

### Page 203

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 747 TO
STA 847
SKIN - LAP SPLICEInspect1
(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower
fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.
Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean
up hole for open hole HFEC inspection.
FIGURE 36: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: May 06, 2019
737-53A1382 RB
203 of 227
REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT

### Page 204 (OCR)

REQUIREMENTS BULLETIN 737-53A1382
ALERT  ALERT
This Figure applies only to: Group 9, Configuration 1; Group 10.
STA
1016
STA
727
<2b 1 e00г
STA  STA
727A  827
STA
1016
000000000  - S-14L
FRAME
FWD
UPPER SKIN
*LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE
/A INSPECTION AREA  2851563
FIGURE 37: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14L - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION
(SHEET 1 OF 2)
Original Issue: May 06, 2019
Export Controlled ECCN: 9E991  737-53A1382 RB
Copyright © Unpublished
Work - See page 1 for details.  204 of 227

The text continues at https://openairdocs.org/service-documents/boeing/737-53a1382/file/bb296ea55e6b.md?from=205

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.