# Boeing Special Attention Requirements Bulletin 737-57-1352 RB: No revision named

- Rights: © The Boeing Company. Filed by the FAA in regulations.gov docket FAA-2021-1168; AD 2022-16-09 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [Boeing Special Attention Requirements Bulletin 737-57-1352 RB](https://openairdocs.org/service-documents/boeing/737-57-1352-rb.md)
- Title as filed: 737-57-1352 RB -- BOEING
- Pages: 48
- PDF: https://openairdocs.org/files/sha256/8d/1a/8d1a0eefe91bb50be5f021ca3e94fb960e2a6aa8df0584f1f73eb86d58ad1ef3
- Page: https://openairdocs.org/service-documents/boeing/737-57-1352-rb/file/8d1a0eefe91b

## Text

Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

Commercial 
Airplanes
737
Requirements Bulletin
SPECIAL ATTENTION
Number: 737-57-1352 RB
Original Issue: February 01, 2021
ATA System: 5720
SUBJECT: WINGS - Outer Wing - Upper and Lower Panel Stringer Fasteners Sealant Application
Export of this technology is controlled under the United States Export Administration Regulations (EAR) (15
CFR 300-774). An export license may be required before it is used for development, production or use by foreign
persons from specific countries. The controller of this data has the individual responsibility to abide by all export
laws.
9E991ECCN:
Copyright © 2021 Boeing.
Unpublished Work. All Rights Reserved.
Treatment of this document and its content is governed by contract with Boeing. Rights to use this document
are licensed on a per aircraft basis and such rights may not be transferable. For more information, contact The
Boeing Company.
Boeing, the Boeing signature, the Boeing symbol, 707, 717, 727, 737, 747, 757, 767, 777, 787, Dreamliner,
BBJ, DC-8, DC-9, DC-10, KC-10, KC-46, KDC-10, MD-10, MD-11, MD-80, MD-88, MD-90, P-8, Poseidon and
Boeing liveries are all trademarks owned by The Boeing Company; and no trademark license is granted in
connection with this document unless provided in writing by Boeing.
Original Issue: February 01, 2021
737-57-1352 RB
1 of 48
2.0

### Page 2

Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
2 of 48
REQUIREMENTS BULLETIN 737-57-1352
BLANK PAGE

### Page 3

Table of Contents
1 . E F F E C T I V I T Y  ................................................ 5
A . A i r p l a n e s  ................................................ 5
B . S p a r e s  A f f e c t e d  ............................................ 5
2. CONCURRENT REQUIREMENTS ..................................... 6
3 . C O M P L I A N C E  ................................................ 6
4. APPROVAL ................................................. 6
5. ACCOMPLISHMENT INSTRUCTIONS .................................. 7
A. General Information .......................................... 7
B. Work Instructions ........................................... 8
FIGURE 1: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S1 SEALANT APPLICATION
.................................................. 1 0
FIGURE 2: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S10 SEALANT APPLICATION
.................................................. 1 3
FIGURE 3: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S12 SEALANT APPLICATION
.................................................. 1 6
FIGURE 4: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S20 SEALANT APPLICATION
.................................................. 1 9
FIGURE 5: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S21 SEALANT APPLICATION
.................................................. 2 2
FIGURE 6: LEFT SIDE WING BOX - LOWER WING PANEL STRINGER L-S14 SEALANT APPLICATION
.................................................. 2 5
FIGURE 7: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S1 SEALANT APPLICATION
.................................................. 2 8
FIGURE 8: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S10 SEALANT APPLICATION
.................................................. 3 1
FIGURE 9: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S12 SEALANT APPLICATION
.................................................. 3 4
FIGURE 10: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S20 SEALANT APPLICATION
.................................................. 3 7
FIGURE 11: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S21 SEALANT APPLICATION
.................................................. 4 0
FIGURE 12: RIGHT SIDE WING BOX - LOWER WING PANEL STRINGER L-S14 SEALANT APPLICATION
.................................................. 4 3
APPENDIX A: INTEGRAL FUEL TANK STRUCTURE - SEALANT APPLICATION ............ 4 6
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
3 of 48
REQUIREMENTS BULLETIN 737-57-1352

### Page 4

Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
4 of 48
REQUIREMENTS BULLETIN 737-57-1352
BLANK PAGE

### Page 5

Commercial 
Airplanes
737
Requirements Bulletin
SPECIAL ATTENTION
Number: 737-57-1352 RB
Original Issue: February 01, 2021
ATA System: 5720
SUBJECT: WINGS - Outer Wing - Upper and Lower Panel Stringer Fasteners Sealant Application
BOEING RECOMMENDS THAT EACH OPERATOR EXAMINE THIS DOCUMENT IMMEDIATELY. THIS IS
AN ENHANCED REQUIRED FOR COMPLIANCE DOCUMENT. THE BOEING PROCESSES USED TO CREATE
THE SERVICE BULLETIN (SB) AND THE REQUIREMENTS BULLETIN (RB) ENSURE THAT THE
INFORMATION BETWEEN "RC START" AND "RC END" IN THE SB ARE IDENTICAL TO THE INFORMATION
IN THE SAME SECTIONS (COMPLIANCE, WORK INSTRUCTIONS…) OF THE RB WHICH THE SB REFERS
TO AS THE RELATED DOCUMENT.
1. Effectivity
A. Airplanes
This bulletin is applicable to 737-8 Airplane(s), line number(s) 5852, 5902, 5948, 5992, 6034, 6074,
6114, 6154, 6188, 6222, 6272, 6290, 6326, 6344, 6360, 6372, 6384, 6396, 6408, 6420, 6430,
6441, 6448, 6456, 6472, 6481, 6499, 6515, 6528, 6535, 6548 in 1 Group(s).
The Variable Numbers and Group Information for the applicable airplanes is given below. Refer
to PRR 3M9900-053RS for data about this change.
DESCRIPTIONCONFIGURATIONGROUP
737-8 Airplane-1
Airplane Models:
737-8
GroupVariable Number
11A005 - 1A014
11A201 - 1A207
11A301 - 1A306
GroupVariable Number
11A401 - 1A403
11B001 - 1B003
11B101
GroupVariable Number
11B201
--
--
B. Spares Affected
None.
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
5 of 48

### Page 6

2. CONCURRENT REQUIREMENTS
None.
3. COMPLIANCE
The Federal Aviation Administration (FAA) will possibly release an Airworthiness Directive related to
Requirements Bulletin 737-57-1352 RB. The Airworthiness Directive will make the compliance tasks and
times given in Requirements Bulletin 737-57-1352 RB mandatory.
Accomplish the required action(s), based on the applicable condition in Table 1, in accordance with
Accomplishment Instructions.
Table 1: Left and Right Side Wing Box Upper and Lower Wing Panel Stringer Black Stripe with
Overcoat and Existing Sealant - Sealant Application
Repeat Interval
(Not to Exceed)
Compliance TimeActionCondition
-Within 10 years af-
ter the date of is-
suance of the origi-
nal airworthiness
certificate or the
original export cer-
tificate of airworthi-
ness.
Completely encapsulate
the black stripe with
overcoat and existing
sealant with BMS5-45
sealant at upper stringer
U-S1, U-S10, U-S12, U-
S20, U-S21 and lower
stringer L-S14 just out-
board of the wing box
side of body.
All Airplanes
4. APPROVAL
This Requirements Bulletin was examined by the Federal Aviation Administration (FAA). The changes
specified in this document comply with the applicable regulations and are FAA approved, as well as European
Union Aviation Safety Agency (EASA)/Joint Aviation Authorities (JAA) approved for all EASA/JAA approved
airplanes listed in the service bulletin effectivity. This document and its approval were based on the airplane
in its original Boeing delivery configuration or as modified by other Boeing changes.
If an airplane has a non-Boeing modification or repair that affects a component or system also affected by
this Requirements Bulletin, the operator is responsible for obtaining appropriate regulatory agency approval
before incorporating this Requirements Bulletin.
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
6 of 48
REQUIREMENTS BULLETIN 737-57-1352

### Page 7

5.    ACCOMPLISHMENT INSTRUCTIONS
A. GENERAL INFORMATION
OBEY THE MANUFACTURER'S PROCEDURES WHEN YOU DO TASKS THAT
ARE RELATED TO AIRWORTHINESS LIMITATIONS (AWL). IF YOU DO NOT
OBEY THE PROCEDURES, IT CAN INCREASE THE RISK OF A SOURCE OF
IGNITION. INJURIES TO PERSONNEL, AND DAMAGE TO EQUIPMENT CAN
OCCUR IF THERE IS A FIRE OR EXPLOSION.
WARNING
NOTE: 1. This is an Enhanced Required for Compliance document. There will be a separate
Service Bulletin (SB) and a separate Requirements Bulletin (RB). If an RB is mandated
by an Airworthiness Directive (AD), then all applicable requirements specified in the
RB must be done. For the related SB, some locations are marked RC Start and RC
End to identify the requirements that are restated from the RB. For the related SB,
the areas between RC Start and RC End, including sub-steps and any figures
identified between RC Start and RC End, must be done to comply with the AD.
Therefore, an Alternative Method of Compliance (AMOC) is required for any deviations
to steps between RC Start and RC End, including substeps and identified figures.
For the related SB, the steps not between RC Start and RC End may be deviated
from using accepted methods in accordance with the operator's maintenance or
inspection program without obtaining approval of an AMOC; this is provided that the
steps between RC Start and RC End, including sub-steps and identified figures, can
still be done as specified, and the airplane can be put back in an airworthy condition.
Figures not required for compliance are omitted from the RB.
2. This is an Enhanced Required for Compliance document. The Boeing processes
used to create the Service Bulletin (SB) and the Requirements Bulletin (RB) ensure
that the information between "RC Start" and "RC End" in the SB are identical to the
information in the same sections (Compliance, Work Instructions...) of the RB which
the SB refers to as the related document.
3. The compliance times for the actions in WORK INSTRUCTIONS are in Compliance.
4. Boeing Service Letter 737-SL-51-042, Damage Reporting and Repair Plan/Design
Guidelines, is an acceptable procedure to request information from Boeing for
additional structural repair instructions. The Service Letter describes what information
must be provided to Boeing before a structural repair can be provided.
5. Unless shown differently, these dimensions and tolerances are used:
– Linear dimensions are in inches
– Tolerance on linear dimensions, other than rivet and bolt edge margins, is plus
or minus 0.03 inch
– Tolerance on rivet and bolt edge margin is plus or minus 0.05 inch
– Angular tolerance is plus or minus 2 degrees
– Hole dimensions for standard solid rivets and fasteners are in Structural Repair
Manual (SRM) Chapter 51
– Torque Values:
— Values for structural fasteners are given in 737 Structural Repair Manual,
Chapter 51.
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
7 of 48
REQUIREMENTS BULLETIN 737-57-1352

### Page 8

— Values for airframe maintenance tasks are included in Chapter 20 of 737
Aircraft Maintenance Manual (AMM).
— Values for electrical maintenance tasks are included in Chapter 20 of
Standard Wiring Practices Manual (SWPM).
— Values for engine maintenance tasks are included in Chapter 70 of 737
Aircraft Maintenance Manual (AMM).
— Non-standard torque values for maintenance tasks are included in the
applicable installation step.
6. These work instructions refer to procedures included in other Boeing documents.
When the words "refer to" are used and the operator has an accepted alternative
procedure, the accepted alternative procedure can be used. When the words "in
accordance with" are included in the instruction, the procedure in the Boeing document
must be used.
7. Where the work instructions include installation of a kept part, a new or serviceable
part with the same part number can be installed as an alternative to the kept part.
8. If it is necessary to remove more parts for access, you can remove those parts. If
you can get access without removing identified parts, it is not necessary to remove
all of the identified parts. Jacking and shoring limitations must be observed.
14. Some Work Instruction tasks are related to Critical Design Configuration Control
Limitations (CDCCL) required by Airworthiness Limitations (AWL) and Certification
Maintenance Requirements (CMR), 737-7/8/8200/9/10 AWL D626A011-9-04. Strict
adherence to Airworthiness Limitations is required.
15. The Work Instructions include access tasks that are related to Critical Design
Configuration Control Limitations (CDCCL) required by 737-8 AWL 28-AWL-16. Strict
adherence to Airworthiness Limitations are required.
B. WORK INSTRUCTIONS
Actions Required for Compliance
1. Requirements
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
8 of 48
REQUIREMENTS BULLETIN 737-57-1352

### Page 9

Table 1: Left Side Wing Box Upper and Lower Wing Panel Stringer Black Stripe with Overcoat and Existing
Sealant - Sealant Application
Refer to the listed proce-
dures in SB 737-57-1352
Original issue or later
approved revisions as an
accepted procedure.
Method of ComplianceActionCondition
PART 1: GET ACCESS
TO THE LEFT CENTER
FUEL TANK
-Completely encapsulate
the black stripe with over-
coat and existing sealant
with BMS5-45 sealant at
upper stringer U-S1, U-
S10, U-S12, U-S20, U-S21
and lower stringer L-S14
just outboard of the wing
box side of body.
All Airplanes
-U-S1: FIGURE 1
U-S10: FIGURE 2
U-S12: FIGURE 3
U-S20: FIGURE 4
U-S21: FIGURE 5
L-S14: FIGURE 6
PART 2: CLOSE ACCESS
TO THE LEFT CENTER
FUEL TANK
-
Table 2: Right Side Wing Box Upper and Lower Wing Panel Stringer Black Stripe with Overcoat and
Existing Sealant - Sealant Application
Refer to the listed proce-
dures in SB 737-57-1352
Original issue or later
approved revisions as an
accepted procedure.
Method of ComplianceActionCondition
PART 3: GET ACCESS
TO THE RIGHT CENTER
FUEL TANK
-Completely encapsulate
the black stripe with over-
coat and existing sealant
with BMS5-45 sealant at
upper stringer U-S1, U-
S10, U-S12, U-S20, U-S21
and lower stringer L-S14
just outboard of the wing
box side of body.
All Airplanes
-U-S1: FIGURE 7
U-S10: FIGURE 8
U-S12: FIGURE 9
U-S20: FIGURE 10
U-S21: FIGURE 11
L-S14: FIGURE 12
PART 4: CLOSE ACCESS
TO THE RIGHT CENTER
FUEL TANK
-
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
9 of 48
REQUIREMENTS BULLETIN 737-57-1352

### Page 10 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
UPPER WING  U-S20
PANEL  U-S21
U-S12
U-S10
RIB 2
B
U-S1
WBL 0
FWD  LEFT WING BOX  LOWER WING  L-S14
PANEL
-U-S1
VIEW LOOKING UP
2945088
FIGURE 1: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S1 SEALANT APPLICATION
(SHEET 1 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.  8010 01

### Page 11 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
STRINGER  STRINGER
UPPER  UPPER
WING  WING
PANEL  PANEL
BLACK  BLACK
STRIPE/  STRIPE/
OVERCOAT  OVERCOAT
BEFORE
1.00 INCH
(MINIMUM)
AFTER
STRINGER
STRINGER
UPPER WING
PANEL
0.30 INCH
0.10
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
A-A  0.12 INCH
(MINIMUM)
UPPER WING
EXISTING SEALANT  PANEL
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
BMS5-45, CLASS A-2 (BRUSHCOAT)  B-B
BMS5-45, CLASS B (ENCAPSULATE)  2945091
FIGURE 1: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S1 SEALANT APPLICATION
(SHEET 2 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  Copyright © Unpublished  737-57-1352 RB
Work - See page 1 for details.  11 of 48

### Page 12

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this task/figure.
More DataQtyIdentificationNameTaskStep
(a)1112A3201-601STRINGER U-S1Clean1
(b)1112A3201-601STRINGER U-S1Prepare
(c)(d)8 OzBMS5-45, CLASS A-2FUEL TANK SEALANTApply2
(e)8 OzBMS5-45, CLASS BFUEL TANK SEALANTApply3
(a) Preliminary clean area for sealant application in accordance with APPENDIX A.
(b) Final clean beyond area shown and remove all contaminant material in accordance with APPENDIX A.
(c) Apply brushcoat with BMS5-45, Class A-2 in accordance with APPENDIX A.
(d) Apply brushcoat to the upper wing panel, existing sealant, blackstripe / overcoat not covered by existing
sealant, stringer and beyond the radius of vertical flange of stringer.
(e) Apply encapsulate BMS5-45 Class B in accordance with APPENDIX A.
FIGURE 1: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S1 SEALANT APPLICATION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
12 of 48
REQUIREMENTS BULLETIN 737-57-1352

### Page 13 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
UPPER WING  U-S20
PANEL  U-S21
U-S10 U-S12
RIB 2
U-S1
LEFT WING BOX  LOWER WING  L-S14
PANEL
*U-S10
INBD
VIEW LOOKING UP
2945092
FIGURE 2: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S10 SEALANT APPLICATION
(SHEET 1 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  Work - See page 1 for details.  Copyright © Unpublished  737-57-1352 RB  13 of 48

### Page 14 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
STRINGER  STRINGER
UPPER
WING
PANEL•
UPPER
WING
PANEL
= ∞-
BLACK
STRIPE/  BLACK  OVERCOAT  STRIPE/
OVERCOAT
BEFORE
• 1.00 INCH
(MINIMUM)
AFTER
STRINGER
UPPER WING  STRINGER
PANEL
- 0.30 INCH
0.10
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
A-A
0.12 INCH
(MINIMUM)
UPPER WING
EXISTING SEALANT  PANEL
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
BMS5-45, CLASS A-2 (BRUSHCOAT)  B-B
BMS5-45, CLASS B (ENCAPSULATE)  2945093
FIGURE 2: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S10 SEALANT APPLICATION
(SHEET 2 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  737-57-1352 RB
Copyright © Unpublished
Work - See page 1 for details.  14 of 48

### Page 15

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this task/figure.
More DataQtyIdentificationNameTaskStep
(a)1112A3210-()STRINGER U-S10Clean1
(b)1112A3210-()STRINGER U-S10Prepare
(c)(d)8 OzBMS5-45, CLASS A-2FUEL TANK SEALANTApply2
(e)8 OzBMS5-45, CLASS BFUEL TANK SEALANTApply3
(a) Preliminary clean area for sealant application in accordance with APPENDIX A.
(b) Final clean beyond area shown and remove all contaminant material in accordance with APPENDIX A.
(c) Apply brushcoat with BMS5-45, Class A-2 in accordance with APPENDIX A.
(d) Apply brushcoat to the upper wing panel, existing sealant, blackstripe / overcoat not covered by existing
sealant, stringer and beyond the radius of vertical flange of stringer.
(e) Apply encapsulate BMS5-45 Class B in accordance with APPENDIX A.
FIGURE 2: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S10 SEALANT APPLICATION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
15 of 48
REQUIREMENTS BULLETIN 737-57-1352

### Page 16 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
UPPER WING U-520
PANEL  U-S21
U-S10 U-S12
RIB 2
U-S1
WBL O
LEFT WING BOX  LOWER WING L-S14
PANEL
*U-S12
VIEW LOOKING UP
2945094
FIGURE 3: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S12 SEALANT APPLICATION
(SHEET 1 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  Copyright © Unpublished  737-57-1352 RB
Work - See page 1 for details.  16 of 48

### Page 17 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
STRINGER  STRINGER
UPPER
WING
PANEL•
UPPER
WING
PANEL
B
BLACK
STRIPE/
BLACK  OVERCOAT •
STRIPE/
OVERCOAT
-
BEFORE  1.00 INCH
(MINIMUM)
AFTER
STRINGER
STRINGER
UPPER WING
• 0.30 INCH
0.10
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
A-A  0.12 INCH
(MINIMUM)  UPPER WING
EXISTING SEALANT  PANEL
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
BMS5-45, CLASS A-2 (BRUSHCOAT)  B-B
BMS5-45, CLASS B (ENCAPSULATE)
FIGURE 3: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S12 SEALANT APPLICATION
(SHEET 2 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  737-57-1352 RB
Work - See page 1 for details.  17 of 48

### Page 18

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this task/figure.
More DataQtyIdentificationNameTaskStep
(a)1112A3212-()STRINGER U-S12Clean1
(b)1112A3212-()STRINGER U-S12Prepare
(c)(d)8 OzBMS5-45, CLASS A-2FUEL TANK SEALANTApply2
(e)8 OzBMS5-45, CLASS BFUEL TANK SEALANTApply3
(a) Preliminary clean area for sealant application in accordance with APPENDIX A.
(b) Final clean beyond area shown and remove all contaminant material in accordance with APPENDIX A.
(c) Apply brushcoat with BMS5-45, Class A-2 in accordance with APPENDIX A.
(d) Apply brushcoat to the upper wing panel, existing sealant, blackstripe / overcoat not covered by existing
sealant, stringer and beyond the radius of vertical flange of stringer.
(e) Apply encapsulate BMS5-45 Class B in accordance with APPENDIX A.
FIGURE 3: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S12 SEALANT APPLICATION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
18 of 48
REQUIREMENTS BULLETIN 737-57-1352

### Page 19 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
PANEL  UPPER WING  B  U-S20  / U-S21
U-S10 -512
RIB 2
U-S1
LEFT WING BOX  LOWER WING  L-S14
PANEL
A
NBD  *U-S20
VIEW LOOKING UP
B  2945096
FIGURE 4: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S20 SEALANT APPLICATION
(SHEET 1 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  Copyright © Unpublished  737-57-1352 RB
Work - See page 1 for details.  19 of 48

### Page 20 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
STRINGER  STRINGER
UPPER
WING
PANEL-
UPPER
WING
PANEL
B
BLACK
STRIPE
OVERCOAT
STRIPE T  BLACK
OVERCOAT
BEFORE
1.00 INCH
(MINIMUM)
AFTER
STRINGER
STRINGER
UPPER WING
PANEL
- 0.30 INCH  0.10
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
A-A  0.12 INCH
(MINIMUM)
UPPER WING
EXISTING SEALANT  PANEL
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
BMS5-45, CLASS A-2 (BRUSHCOAT)  B-B
BMS5-45, CLASS B (ENCAPSULATE)  2945097
FIGURE 4: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S20 SEALANT APPLICATION
(SHEET 2 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  737-57-1352 RB
Work - See page 1 for details.  Copyright © Unpublished  20 of 48

### Page 21

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this task/figure.
More DataQtyIdentificationNameTaskStep
(a)1112A3220-601STRINGER U-S20Clean1
(b)1112A3220-601STRINGER U-S20Prepare
(c)(d)8 OzBMS5-45, CLASS A-2FUEL TANK SEALANTApply2
(e)8 OzBMS5-45, CLASS BFUEL TANK SEALANTApply3
(a) Preliminary clean area for sealant application in accordance with APPENDIX A.
(b) Final clean beyond area shown and remove all contaminant material in accordance with APPENDIX A.
(c) Apply brushcoat with BMS5-45, Class A-2 in accordance with APPENDIX A.
(d) Apply brushcoat to the upper wing panel, existing sealant, blackstripe / overcoat not covered by existing
sealant, stringer and beyond the radius of vertical flange of stringer.
(e) Apply encapsulate BMS5-45 Class B in accordance with APPENDIX A.
FIGURE 4: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S20 SEALANT APPLICATION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
21 of 48
REQUIREMENTS BULLETIN 737-57-1352

### Page 22 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
UPPER WING  U-S20
PANEL  U-S21
U-S10 U-S12
RIB 2
U-S1
WBL O
FWD  LEFT WING BOX  LOWER WING  L-S14
PANEL
*U-S21
VIEW LOOKING UP
2945098
FIGURE 5: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S21 SEALANT APPLICATION
(SHEET 1 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  Copyright © Unpublished  737-57-1352 RB
Work - See page 1 for details.  22 of 48

### Page 23 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
STRINGER  STRINGER
UPPER
UPPER  WING
WING  PANEL
PANEL•
STRIPE/  BLACK  OVERCOAT  STRIPE/  BLACK
OVERCOAT
BEFORE
- 1.00 INCH
(MINIMUM)
AFTER
STRINGER
UPPER WING  STRINGER
PANEL
0.30 INCH  0.10
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
A-A
0.12 INCH
(MINIMUM)  UPPER WING
PANEL
EXISTING SEALANT
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
BMS5-45, CLASS A-2 (BRUSHCOAT)  B-B
BMS5-45, CLASS B (ENCAPSULATE)  2945099
FIGURE 5: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S21 SEALANT APPLICATION
(SHEET 2 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  Work - See page 1 for details.  Copyright © Unpublished  737-57-1352 RB  23 of 48

### Page 24

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this task/figure.
More DataQtyIdentificationNameTaskStep
(a)1112A3221-601STRINGER U-S21Clean1
(b)1112A3221-601STRINGER U-S21Prepare
(c)(d)8 OzBMS5-45, CLASS A-2FUEL TANK SEALANTApply2
(e)8 OzBMS5-45, CLASS BFUEL TANK SEALANTApply3
(a) Preliminary clean area for sealant application in accordance with APPENDIX A.
(b) Final clean beyond area shown and remove all contaminant material in accordance with APPENDIX A.
(c) Apply brushcoat with BMS5-45, Class A-2 in accordance with APPENDIX A.
(d) Apply brushcoat to the upper wing panel, existing sealant, blackstripe / overcoat not covered by existing
sealant, stringer and beyond the radius of vertical flange of stringer.
(e) Apply encapsulate BMS5-45 Class B in accordance with APPENDIX A.
FIGURE 5: LEFT SIDE WING BOX - UPPER WING PANEL STRINGER U-S21 SEALANT APPLICATION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
24 of 48
REQUIREMENTS BULLETIN 737-57-1352

### Page 25 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
UPPER WING  U-S20
PANEL  U-S21
U-S10 U-S12
RIB 2
U-S1
LEFT WING BOX  LOWER WING  L-S14
PANEL
L-S14
VIEW LOOKING DOWN
INBD  2945100
FIGURE 6: LEFT SIDE WING BOX - LOWER WING PANEL STRINGER L-S14 SEALANT APPLICATION
(SHEET 1 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  Copyright © Unpublished  737-57-1352 RB
Work - See page 1 for details.  25 of 48

### Page 26 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
STRINGER
STRINGER
LOWER
WING
PANEL  LOWER
WING
PANEL
B
BLACK
STRIPE  BLACK
OVERCOAT  STRIPE/
OVERCOAT
/
BEFORE
1.00 INCH
(MINIMUM)
AFTER
STRINGER
LOWER WING  STRINGER
PANEL
- 0.30 INCH
0.10
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
A-A
0.12 INCH
(MINIMUM)
LOWER WING
EXISTING SEALANT  PANEL
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
BMS5-45, CLASS A-2 (BRUSHCOAT)  B-B
BMS5-45, CLASS B (ENCAPSULATE)  2945101
FIGURE 6: LEFT SIDE WING BOX - LOWER WING PANEL STRINGER L-S14 SEALANT APPLICATION
(SHEET 2 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  737-57-1352 RB
Work - See page 1 for details.  Copyright © Unpublished  26 of 48

### Page 27

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this task/figure.
More DataQtyIdentificationNameTaskStep
(a)1112A4214-601STRINGER L-S14Clean1
(b)1112A4214-601STRINGER L-S14Prepare
(c)(d)8 OzBMS5-45, CLASS A-2FUEL TANK SEALANTApply2
(e)8 OzBMS5-45, CLASS BFUEL TANK SEALANTApply3
(a) Preliminary clean area for sealant application in accordance with APPENDIX A.
(b) Final clean beyond area shown and remove all contaminant material in accordance with APPENDIX A.
(c) Apply brushcoat with BMS5-45, Class A-2 in accordance with APPENDIX A.
(d) Apply brushcoat to the lower wing panel, existing sealant, blackstripe / overcoat not covered by existing
sealant, stringer and beyond the radius of vertical flange of stringer.
(e) Apply encapsulate BMS5-45 Class B in accordance with APPENDIX A.
FIGURE 6: LEFT SIDE WING BOX - LOWER WING PANEL STRINGER L-S14 SEALANT APPLICATION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
27 of 48
REQUIREMENTS BULLETIN 737-57-1352

### Page 28 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
U-S20  UPPER WING
U-S21  PANEL
U-S12 U-S10
RIB 2
B
U-S1
WBI
L-S14  LOWER WING  RIGHT WING BOX
PANEL
U-S1 -  INBD
VIEW LOOKING UP
2945104
FIGURE 7: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S1 SEALANT APPLICATION
(SHEET 1 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  737-57-1352 RB
Copyright © Unpublished
Work - See page 1 for details.  28 of 48

### Page 29 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
STRINGER  STRINGER
UPPER  UPPER
WING  WING
•PANEL  - PANEL
A
BLACK  BLACK
STRIPE/  STRIPE/
OVERCOAT  OVERCOAT
BEFORE  (MINIMUM)  1.00 INCH
AFTER
STRINGER
STRINGER
UPPER WING  PANEL  + 0.30 INCH  0.10
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)  0.12 INCH
A-A  UPPER WING  (MINIMUM)
PANEL
EXISTING SEALANT  (BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
B-B
BMS5-45, CLASS A-2 (BRUSHCOAT)
BMS5-45, CLASS B (ENCAPSULATE)
FIGURE 7: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S1 SEALANT APPLICATION
(SHEET 2 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  Copyright © Unpublished  737-57-1352 RB
Work - See page 1 for details.  29 of 48

### Page 30

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this task/figure.
More DataQtyIdentificationNameTaskStep
(a)1112A3201-602STRINGER U-S1Clean1
(b)1112A3201-602STRINGER U-S1Prepare
(c)(d)8 OzBMS5-45, CLASS A-2FUEL TANK SEALANTApply2
(e)8 OzBMS5-45, CLASS BFUEL TANK SEALANTApply3
(a) Preliminary clean area for sealant application in accordance with APPENDIX A.
(b) Final clean beyond area shown and remove all contaminant material in accordance with APPENDIX A.
(c) Apply brushcoat with BMS5-45, Class A-2 in accordance with APPENDIX A.
(d) Apply brushcoat to the upper wing panel, existing sealant, blackstripe / overcoat not covered by existing
sealant, stringer and beyond the radius of vertical flange of stringer.
(e) Apply encapsulate BMS5-45 Class B in accordance with APPENDIX A.
FIGURE 7: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S1 SEALANT APPLICATION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
30 of 48
REQUIREMENTS BULLETIN 737-57-1352

### Page 31 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
U-S20  UPPER WING
U-S21  PANEL
U-S12 U-S10  B
RIB 2
U-S1
WBL O
L-S14  LOWER WING  PANEL  RIGHT WING BOX  FWD
U-S10
INBD
VIEW LOOKING UP
2045255
FIGURE 8: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S10 SEALANT APPLICATION
(SHEET 1 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  731-51-1352 RE
Work - See page 1 for details.  31 of 48

### Page 32 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
STRINGER  STRINGER
UPPER  2
WING
• PANEL
UPPER
WING
- PANEL
BLACK
BLACK  STRIPE/
STRIPE/  OVERCOAT
OVERCOAT
BEFORE  1.00 INCH
(MINIMUM)
AFTER
STRINGER
STRINGER
UPPER WING
PANEL  -0.10 INCH
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
A-A  0.12 INCH
UPPER WING  (MINIMUM)
PANEL
EXISTING SEALANT
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
BMS5-45, CLASS A-2 (BRUSHCOAT)  B-B
BMS5-45, CLASS B (ENCAPSULATE)  2945256
FIGURE 8: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S10 SEALANT APPLICATION
(SHEET 2 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  737-57-1352 RB
Work - See page 1 for details.  Copyright © Unpublished  32 of 48

### Page 33

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this task/figure.
More DataQtyIdentificationNameTaskStep
(a)1112A3210-()STRINGER U-S10Clean1
(b)1112A3210-()STRINGER U-S10Prepare
(c)(d)8 OzBMS5-45, CLASS A-2FUEL TANK SEALANTApply2
(e)8 OzBMS5-45, CLASS BFUEL TANK SEALANTApply3
(a) Preliminary clean area for sealant application in accordance with APPENDIX A.
(b) Final clean beyond area shown and remove all contaminant material in accordance with APPENDIX A.
(c) Apply brushcoat with BMS5-45, Class A-2 in accordance with APPENDIX A.
(d) Apply brushcoat to the upper wing panel, existing sealant, blackstripe / overcoat not covered by existing
sealant, stringer and beyond the radius of vertical flange of stringer.
(e) Apply encapsulate BMS5-45 Class B in accordance with APPENDIX A.
FIGURE 8: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S10 SEALANT APPLICATION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
33 of 48
REQUIREMENTS BULLETIN 737-57-1352

### Page 34 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
U-S20  UPPER WING
U-S21  PANEL  B
0S12 U-S10
RIB 2
U-S1
WBL O
L-S14  LOWER WING  RIGHT WING BOX
PANEL
U-S12
NBD
VIEW LOOKING UP
2945257
FIGURE 9: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S12 SEALANT APPLICATION
(SHEET 1 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  Copyright © Unpublished  737-57-1352 RB
Work - See page 1 for details.  34 of 48

### Page 35 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
STRINGER  STRINGER
UPPER
WING
• PANEL  UPPER
WING
• PANEL
A
4
• BLACK
BLACK  STRIPE/
STRIPE/  OVERCOAT
OVERCOAT
BEFORE
1.00 INCH
(MINIMUM)
AFTER
STRINGER
UPPER
WING
PANEL  STRINGER
-0.S0 INCH  0.10
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
A-A
0.12 INCH
UPPER WING  (MINIMUM)
PANEL
EXISTING SEALANT
BMS5-45, CLASS A-2 (BRUSHCOAT)  (BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
BMS5-45, CLASS B (ENCAPSULATE)  B-B  2945958
FIGURE 9: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S12 SEALANT APPLICATION
(SHEET 2 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  Work - See page 1 for details.  Copyright © Unpublished  737-57-1352 RB  35 of 48

### Page 36

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1112A3212-()STRINGER U-S12Clean1
(b)1112A3212-()STRINGER U-S12Prepare
(c)(d)8 OzBMS5-45, CLASS A-2FUEL TANK SEALANTApply2
(e)8 OzBMS5-45, CLASS BFUEL TANK SEALANTApply3
(a) Preliminary clean area for sealant application in accordance with APPENDIX A.
(b) Final clean beyond area shown and remove all contaminant material in accordance with APPENDIX A.
(c) Apply brushcoat with BMS5-45, Class A-2 in accordance with APPENDIX A.
(d) Apply brushcoat to the upper wing panel, existing sealant, blackstripe / overcoat not covered by existing
sealant, stringer and beyond the radius of vertical flange of stringer.
(e) Apply encapsulate BMS5-45 Class B in accordance with APPENDIX A.
FIGURE 9: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S12 SEALANT APPLICATION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
36 of 48
REQUIREMENTS BULLETIN 737-57-1352

### Page 37 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
U-S20  UPPER WING
U-S21  PANEL
U-S12 U-S10
RIB 2
U-S1
VBL O
L-S14  LOWER WING  RIGHT WING BOX
PANEL
INBD
U-S20
VIEW LOOKING UP
2045259
FIGURE 10: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S20 SEALANT APPLICATION
(SHEET 1 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  Copyright © Unpublished  737-57-1352 RB
Work - See page 1 for details.  37 of 48

### Page 38 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
STRINGER
STRINGER
UPPER
WING
• PANEL
UPPER
WING
• PANEL
A
B
BLACK
STRIPE/
OVERCOAT
BLACK
STRIPE/
OVERCOAT
BEFORE
1.00 INCH
(MINIMUM)
AFTER
STRINGER
UPPER  STRINGER
WING
PANEL  - 0.10 INCH
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
A-A  0.12 INCH
UPPER WING  (MINIMUM)
PANEL
EXISTING SEALANT  (BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
B-B
BMS5-45, CLASS A-2 (BRUSHCOAT)
BMS5-45, CLASS B (ENCAPSULATE)  2945260
FIGURE 10: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S20 SEALANT APPLICATION
(SHEET 2 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  737-57-1352 RB
Copyright © Unpublished
Work - See page 1 for details.  38 of 48

### Page 39

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1112A3220-602STRINGER U-S20Clean1
(b)1112A3220-602STRINGER U-S20Prepare
(c)(d)8 OzBMS5-45, CLASS A-2FUEL TANK SEALANTApply2
(e)8 OzBMS5-45, CLASS BFUEL TANK SEALANTApply3
(a) Preliminary clean area for sealant application in accordance with APPENDIX A.
(b) Final clean beyond area shown and remove all contaminant material in accordance with APPENDIX A.
(c) Apply brushcoat with BMS5-45, Class A-2 in accordance with APPENDIX A.
(d) Apply brushcoat to the upper wing panel, existing sealant, blackstripe / overcoat not covered by existing
sealant, stringer and beyond the radius of vertical flange of stringer.
(e) Apply encapsulate BMS5-45 Class B in accordance with APPENDIX A.
FIGURE 10: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S20 SEALANT APPLICATION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
39 of 48
REQUIREMENTS BULLETIN 737-57-1352

### Page 40 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
U-S20  UPPER WING
U-S21  PANEL
U-S12  U-S10
RIB 2
я да корру  U-S1
WBL O
L-S14  LOWER WING  RIGHT WING BOX
PANEL
INBD
U-S21
VIEW LOOKING UP
B  2945265
FIGURE 11: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S21 SEALANT APPLICATION
(SHEET 1 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  737-57-1352 RB
Copyright © Unpublished
Work - See page 1 for details.  40 of 48

### Page 41 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
STRINGER  STRINGER
UPPER  UPPER
WING  WING
-PANEL  -PANEL
BLACK
STRIPE/  BLACK
OVERCOAT  STRIPE/
OVERCOAT
BEFORE
•1.00 INCH
(MINIMUM)
AFTER
STRINGER
UPPER  STRINGER
WING
PANEL  - 0.30 INCH
0.10
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
A-A  0.12 INCH
UPPER WING  (MINIMUM)
PANEL
EXISTING SEALANT
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
BMS5-45, CLASS A-2 (BRUSHCOAT)  B-B
BMS5-45, CLASS B (ENCAPSULATE)  2945268
FIGURE 11: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S21 SEALANT APPLICATION
(SHEET 2 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  Copyright © Unpublished  737-57-1352 RB
Work - See page 1 for details.  41 of 48

### Page 42

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1112A3221-602STRINGER U-S21Clean1
(b)1112A3221-602STRINGER U-S21Prepare
(c)(d)8 OzBMS5-45, CLASS A-2FUEL TANK SEALANTApply2
(e)8 OzBMS5-45, CLASS BFUEL TANK SEALANTApply3
(a) Preliminary clean area for sealant application in accordance with APPENDIX A.
(b) Final clean beyond area shown and remove all contaminant material in accordance with APPENDIX A.
(c) Apply brushcoat with BMS5-45, Class A-2 in accordance with APPENDIX A.
(d) Apply brushcoat to the upper wing panel, existing sealant, blackstripe / overcoat not covered by existing
sealant, stringer and beyond the radius of vertical flange of stringer.
(e) Apply encapsulate BMS5-45 Class B in accordance with APPENDIX A.
FIGURE 11: RIGHT SIDE WING BOX - UPPER WING PANEL STRINGER U-S21 SEALANT APPLICATION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
42 of 48
REQUIREMENTS BULLETIN 737-57-1352

### Page 43 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
U-S20  UPPER WING
U-S21  PANEL
U-S12 U-S10
RIB 2
U-S1
WBL O
L-S14  LOWER WING  RIGHT WING BOX  FWD
PANEL
B
L-S14
VIEW LOOKING DOWN
INBD  2045260
FIGURE 12: RIGHT SIDE WING BOX - LOWER WING PANEL STRINGER L-S14 SEALANT APPLICATION
(SHEET 1 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  Copyright © Unpublished  737-57-1352 RB
Work - See page 1 for details.  43 of 48

### Page 44 (OCR)

REQUIREMENTS BULLETIN 737-57-1352
STRINGER
STRINGER
LOWER
WING
•PANEL  LOWER
WING
-PANEL
BLACK  BLACK
STRIPE/  STRIPE/
OVERCOAT  OVERCOAT
BEFORE  •1.00 INCH
(MINIMUM)
AFTER
STRINGER  D
LOWER  STRINGER
WING
PANEL  -0.10 INCH
(BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
A-A  LOWER WING  0.12 INCH  (MINIMUM)
PANEL
EXISTING SEALANT  (BLACK STRIPE AND OVERCOAT ARE NOT SHOWN)
BMS5-45, CLASS A-2 (BRUSHCOAT)  B-B
BMS5-45, CLASS B (ENCAPSULATE)  2945270
FIGURE 12: RIGHT SIDE WING BOX - LOWER WING PANEL STRINGER L-S14 SEALANT APPLICATION
(SHEET 2 OF 3)
Original Issue: February 01, 2021
Export Controlled ECCN: 9E991  737-57-1352 RB
Work - See page 1 for details.  Copyright © Unpublished  44 of 48

### Page 45

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1112A4214-602STRINGER L-S14Clean1
(b)1112A4214-602STRINGER L-S14Prepare
(c)(d)8 OzBMS5-45, CLASS A-2FUEL TANK SEALANTApply2
(e)8 OzBMS5-45, CLASS BFUEL TANK SEALANTApply3
(a) Preliminary clean area for sealant application in accordance with APPENDIX A.
(b) Final clean beyond area shown and remove all contaminant material in accordance with APPENDIX A.
(c) Apply brushcoat with BMS5-45, Class A-2 in accordance with APPENDIX A.
(d) Apply brushcoat to the lower wing panel, existing sealant, blackstripe / overcoat not covered by existing
sealant, stringer and beyond the radius of vertical flange of stringer.
(e) Apply encapsulate BMS5-45 Class B in accordance with APPENDIX A.
FIGURE 12: RIGHT SIDE WING BOX - LOWER WING PANEL STRINGER L-S14 SEALANT APPLICATION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
45 of 48
REQUIREMENTS BULLETIN 737-57-1352

### Page 46

INTEGRAL FUEL TANK STRUCTURE - SEALANT APPLICATION
1. Clean area:
a. Preliminary Cleaning
(1) Remove all solid contaminants from assembled faying surfaces using compressed air or
vacuuming. Vacuuming is preferred over compressed air to prevent the spread of contamination
to other areas.
(2) Perform preliminary solvent cleaning using solvent dispensed onto wiping materials or onto
clean bristle brushes. Avoid using excessive solvent. Scrub surfaces using wiping materials
wet with solvent, change wiping material often, and repeat cleaning until wiping materials are
free of soil and contaminants, including ink markings. Wipe surface dry with clean dry wipers
while surface is still wet.
TABLE 1: Preliminary Cleaning Solvents
Preliminary Cleaning Solvents
Biogenic SE377C, Rochester Midland Corp.
Citra Safe, Inland Technology, Inc., 401 East 27th Street, Tacoma, WA
TABLE 2: Wiping Materials
Wiping Materials
Gauze sponges, Johnson and Johnson
BMS15-5, Class A, Wiper, Absorbent, Process Cleaning
Cotton Swabs, Purwipe, American Fiber and Finishing Inc., Tianjin Senyang Wood Co. Ltd.
b. Final Cleaning
(1) Perform final cleaning of all surfaces to be sealed immediatly prior to sealant application. Use
solvent dispensed onto new clean wiping materials. Wipe surfaces dry before solvent
evaporates using new dry wiping materials. Change wiping materials often.
(2) Scrub the sealant application area with solvent dampened wipers to remove surface gloss.
INADEQUATE OR IMPROPER REMOVAL (CLEANING) OF MATERIALS
SUCH AS DIRT, CHIPS AND DRILLING OR COLD-WORKING
LUBRICANTS CAN CAUSE FUEL LEAKSCAUTION
(3) Protect and handle all cleaned areas in such a manner that they do not become contaminated.
APPENDIX A:  INTEGRAL FUEL TANK STRUCTURE - SEALANT APPLICATION
(SHEET 1 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
46 of 48
REQUIREMENTS BULLETIN 737-57-1352

### Page 47

TABLE 3: Preliminary and Final Cleaning Solvents
Preliminary and Final Cleaning Solvents
BMS11-7, Cleaning Solvent, Pre-Sealing
Methyl Ethyl Ketone, ASTM D740, Type 1
BMS11-9, Methyl Propyl Ketone (MPK)
Mixture by volume, 42+/- 2 percent Methyl Ethyl Ketone (ASTM D740) and
Mixture by volume, 58 +/- 2 percent Sec-Butyl Alcohol (ASTM D 1007)
See TABLE 2 for wiping materials.
c. Apply Brushcoat and Encapsulate Sealant:
THINNING THE SEALANT MAY RESULT IN ADHESION FAILURES OF
THE SEALANT TO THE SUBSTRATE AND CAN CAUSE FUEL LEAKSCAUTION
(1) Do not add thinner (MEK) to BMS5-45, Class A-2 sealant.
(2) Apply the brushcoat sealant, BMS5-45, Class A-2 to the surface with a sealant-gun nozzle or
stiff, non-metallic bristle brush. Brush sealant vigorously using a scrubbing motion into and
around crevices, holes, seams, fasteners and surfaces to be sealed. Entire surface shall be
coated with sealant.
(a) Apply BMS5-45, Class A-2 brushcoat within the application time specified in TABLE 4.
When applied from an open container, brushcoat will remain suitable throughout its
application time. Do not use containers that are wax coated.
(b) Apply the brushcoat to an area larger than the application area of the subsequently applied
BMS5-45, Class B sealant.
1) Sufficient surface must be coated so that brushcoat is visible and extends 0.1 to 0.3
inch beyond encapsulation BMS 5-45 Class B sealant after completion of sealing.
TABLE 4: Sealant Application Time
(Standard Conditions: 75+/- 5 F and 50+/- 5 percent Relative Humidity)
Curing Time
(Hrs)
Tack-Free Time
(Hrs)
Squeeze-Out
Life (Hrs)
Application
Time (Hrs)
ClassSealant
72.0036.00N/A2.00A-2 (Grade 1)BMS5-45
48.0024.00N/A2.00A-2 (Grade 2)
12.0010.00N/A0.50B-1/2
24.0012.006.002.00B-2
APPENDIX A:  INTEGRAL FUEL TANK STRUCTURE - SEALANT APPLICATION
(SHEET 2 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
47 of 48
REQUIREMENTS BULLETIN 737-57-1352

### Page 48

(3) At any time after brushcoating, encapsulate the area with BMS5-45, Class B sealant with a
sealant gun nozzle, a brush or a fairing tool.
(a) If previous applied brushcoat is cured to a tack-free condition, solvent clean the tack-free
sealant to remove gloss using appropriate materials from TABLE 2 and TABLE 3 prior
to BMS5-45, Class B application.
(b) Apply a minimum of 0.12 inch thick encapsulate sealant and fair up to 0.1 inch to 0.3 inch
from the previous brushcoat application edge. The application and fairing of sealant
should be done before the end of its application time specified in TABLE 4.
APPENDIX A:  INTEGRAL FUEL TANK STRUCTURE - SEALANT APPLICATION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 01, 2021
737-57-1352 RB
48 of 48
REQUIREMENTS BULLETIN 737-57-1352

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.